Literature DB >> 19865827

Non-invasive haemodynamic assessments using Innocor during standard graded exercise tests.

Piero Fontana1, Urs Boutellier, Marco Toigo.   

Abstract

Cardiac output (Q) and stroke volume (V(S)) represent primary determinants of cardiovascular performance and should therefore be determined for performance diagnostics purposes. Since it is unknown, whether measurements of Q and V(S) can be performed by means of Innocor during standard graded exercise tests (GXTs), and whether current GXT stages are sufficiently long for the measurements to take place, we determined Q and V(S) at an early and late point in time on submaximal 2 min GXT stages. 16 male cyclists (age 25.4 +/- 2.9 years, body mass 71.2 +/- 5.0 kg) performed three GXTs and we determined Q and V(S) after 46 and 103 s at 69, 77, and 85% peak power. We found that the rebreathings could easily be incorporated into the GXTs and that Q and V(S) remained unchanged between the two points in time on the same GXT stage (69% peak power, Q: 18.1 +/- 2.1 vs. 18.2 +/- 2.3 l min(-1), V(S): 126 +/- 18 vs. 123 +/- 21 ml; 77% peak power, Q: 20.7 +/- 2.6 vs. 21.0 +/- 2.3 l min(-1), V(S): 132 +/- 18 vs. 131 +/- 18 ml; 85% peak power, Q: 21.6 +/- 2.4 vs. 21.8 +/- 2.7 l min(-1), V(S): 131 +/- 17 vs. 131 +/- 22 ml). We conclude that Innocor may be a useful device for assessing Q and V(S) during GXTs, and that the adaptation of Q and V(S) to exercise-to-exercise transitions at moderate to high submaximal power outputs is fast enough for 1 and 2 min GXT stage durations.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19865827     DOI: 10.1007/s00421-009-1252-x

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  24 in total

1.  Maximal muscular vascular conductances during whole body upright exercise in humans.

Authors:  J A L Calbet; M Jensen-Urstad; G van Hall; H-C Holmberg; H Rosdahl; B Saltin
Journal:  J Physiol       Date:  2004-04-30       Impact factor: 5.182

2.  Influence of testing protocol on ventilatory thresholds and cycling performance.

Authors:  Markus Amann; Andrew Subudhi; Carl Foster
Journal:  Med Sci Sports Exerc       Date:  2004-04       Impact factor: 5.411

3.  Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: a new tool for heart failure evaluation.

Authors:  Piergiuseppe Agostoni; Gaia Cattadori; Anna Apostolo; Mauro Contini; Pietro Palermo; Giancarlo Marenzi; Karlman Wasserman
Journal:  J Am Coll Cardiol       Date:  2005-10-10       Impact factor: 24.094

4.  Point: in health and in a normoxic environment, VO2 max is limited primarily by cardiac output and locomotor muscle blood flow.

Authors:  Bengt Saltin; José A L Calbet
Journal:  J Appl Physiol (1985)       Date:  2006-02

5.  Reliability of measurements with Innocor during exercise.

Authors:  P Fontana; U Boutellier; M Toigo
Journal:  Int J Sports Med       Date:  2009-07-29       Impact factor: 3.118

6.  Kinetics of cardiac output and respiratory gas exchange during exercise and recovery.

Authors:  C T Davies; P E Di Prampero; P Cerretelli
Journal:  J Appl Physiol       Date:  1972-05       Impact factor: 3.531

7.  Phase I dynamics of cardiac output, systemic O2 delivery, and lung O2 uptake at exercise onset in men in acute normobaric hypoxia.

Authors:  Frédéric Lador; Enrico Tam; Marcel Azabji Kenfack; Michela Cautero; Christian Moia; Denis R Morel; Carlo Capelli; Guido Ferretti
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2008-05-21       Impact factor: 3.619

8.  Hypoxemia increases plasma catecholamine concentrations in exercising humans.

Authors:  P Escourrou; D G Johnson; L B Rowell
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1984-11

9.  Plasma catecholamines and heart rate at the beginning of muscular exercise in man.

Authors:  C Orizio; R Perini; A Comandè; M Castellano; M Beschi; A Veicsteinas
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1988

10.  Muscular and pulmonary O2 uptake kinetics during moderate- and high-intensity sub-maximal knee-extensor exercise in humans.

Authors:  P Krustrup; A M Jones; D P Wilkerson; J A L Calbet; J Bangsbo
Journal:  J Physiol       Date:  2009-03-02       Impact factor: 5.182

View more
  9 in total

Review 1.  [Hemodynamics and physical capacity in patients with left ventricular assist devices : An overview].

Authors:  N Reiss; M Altesellmeier; S Mommertz; T Schmidt; S Schulte-Eistrup; D Willemsen
Journal:  Herz       Date:  2016-02-11       Impact factor: 1.443

2.  A comparative evaluation of electrical velocimetry and inert gas rebreathing for the non-invasive assessment of cardiac output.

Authors:  Frederik Trinkmann; Manuel Berger; Ursula Hoffmann; Martin Borggrefe; Jens J Kaden; Joachim Saur
Journal:  Clin Res Cardiol       Date:  2011-07-01       Impact factor: 5.460

3.  Haemodynamics of aerobic and resistance blood flow restriction exercise in young and older adults.

Authors:  Craig A Staunton; Anthony K May; Christopher R Brandner; Stuart A Warmington
Journal:  Eur J Appl Physiol       Date:  2015-07-04       Impact factor: 3.078

4.  The impact of pulmonary disease on noninvasive measurement of cardiac output by the inert gas rebreathing method.

Authors:  Joachim Saur; Frederik Trinkmann; Christina Doesch; Armin Scherhag; Joachim Brade; Stefan O Schoenberg; Martin Borggrefe; Jens J Kaden; Theano Papavassiliu
Journal:  Lung       Date:  2010-07-31       Impact factor: 2.584

5.  Cardiac output but not stroke volume is similar in a Wingate and VO2peak test in young men.

Authors:  Piero Fontana; Katharina Betschon; Urs Boutellier; Marco Toigo
Journal:  Eur J Appl Physiol       Date:  2010-09-17       Impact factor: 3.078

6.  Noninvasive cardiac output determination for children by the inert gas-rebreathing method.

Authors:  Gesa Wiegand; Gunter Kerst; Winfried Baden; Michael Hofbeck
Journal:  Pediatr Cardiol       Date:  2010-10-13       Impact factor: 1.655

7.  Comparative Noninvasive Measurement of Cardiac Output Based on the Inert Gas Rebreathing Method (Innocor®) and MRI in Patients with Univentricular Hearts.

Authors:  Miriam Kuhn; Andreas Hornung; Heidi Ulmer; Christian Schlensak; Michael Hofbeck; Gesa Wiegand
Journal:  Pediatr Cardiol       Date:  2018-02-03       Impact factor: 1.655

8.  Evaluation of inert gas rebreathing for determination of cardiac output: influence of age, gender and body size.

Authors:  Jessica E Middlemiss; Alex Cocks; Kaido Paapstel; Kaisa M Maki-Petaja; Ian B Wilkinson; Carmel M McEniery
Journal:  Hypertens Res       Date:  2018-12-18       Impact factor: 3.872

9.  Moderate Intensity Intermittent Exercise Modality May Prevent Cardiovascular Drift.

Authors:  Muzaffer Colakoglu; Ozgur Ozkaya; Gorkem Aybars Balci
Journal:  Sports (Basel)       Date:  2018-09-15
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.