Literature DB >> 20941596

Noninvasive cardiac output determination for children by the inert gas-rebreathing method.

Gesa Wiegand1, Gunter Kerst, Winfried Baden, Michael Hofbeck.   

Abstract

Standard methods for determination of cardiac output (CO) are either invasive or technically demanding. Measurement of CO by the inert gas-rebreathing (IGR) method, applied successfully in adults, uses a low-concentration mixture of an inert and a blood-soluble gas, respectively. This study tested the feasibility of this method for determining CO during exercise for pediatric patients with complete congenital atrioventricular block (CCAVB) stimulated with a VVI pacemaker. In this study, 5 CCAVB patients (age 9.2-17.4 years) were compared with 10 healthy age-matched boys and girls. Testing was performed with the Innocor system. The patients were instructed to breathe the test gas from a closed system. Pulmonary blood flow was calculated according to the washout of the soluble gas component. During standardized treadmill testing, CO was determined at three defined levels. The CO measurements were successful for all the study participants. The patients reached a lower peak CO than the control subjects (5.9 l/min/m(2) vs 7.3 [boys] and 7.2 [girls]). The stroke volume increase under exercise also was reduced in the patients compared with the control subjects. The feasibility of the IGR method for exercise CO testing in children was documented. Application of the IGR method for children requires careful instruction of the patients and appears restricted to subjects older than 8 years. The method offers new insights into mechanisms of cardiovascular adaptation in children with congenital heart disease.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20941596     DOI: 10.1007/s00246-010-9806-6

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  21 in total

1.  Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: a new tool for heart failure evaluation.

Authors:  Piergiuseppe Agostoni; Gaia Cattadori; Anna Apostolo; Mauro Contini; Pietro Palermo; Giancarlo Marenzi; Karlman Wasserman
Journal:  J Am Coll Cardiol       Date:  2005-10-10       Impact factor: 24.094

2.  Reliability of measurements with Innocor during exercise.

Authors:  P Fontana; U Boutellier; M Toigo
Journal:  Int J Sports Med       Date:  2009-07-29       Impact factor: 3.118

Review 3.  Congenital complete heart block: an international study of the natural history.

Authors:  M Michaëlsson; M A Engle
Journal:  Cardiovasc Clin       Date:  1972

4.  Dilated cardiomyopathy following right ventricular pacing for AV block in young patients: resolution after upgrading to biventricular pacing systems.

Authors:  Jeffrey P Moak; Keren Hasbani; Carolyn Ramwell; Vicki Freedenberg; John T Berger; Gregory DiRusso; Patrick Callahan
Journal:  J Cardiovasc Electrophysiol       Date:  2006-10

5.  An evaluation of a noninvasive cardiac output measurement using partial carbon dioxide rebreathing in children.

Authors:  Richard J Levy; Rosetta M Chiavacci; Susan C Nicolson; Jonathan J Rome; Richard J Lin; Mark A Helfaer; Vinay M Nadkarni
Journal:  Anesth Analg       Date:  2004-12       Impact factor: 5.108

6.  Usefulness of non-invasive measurement of cardiac output during sub-maximal exercise to predict outcome in patients with chronic heart failure.

Authors:  Ayumi Goda; Chim C Lang; Paula Williams; Margaret Jones; Mary Jane Farr; Donna M Mancini
Journal:  Am J Cardiol       Date:  2009-10-14       Impact factor: 2.778

7.  A metabolic cart for measurement of oxygen uptake during human exercise using inspiratory flow rate.

Authors:  Kurt Jensen; Susanne Jørgensen; Lars Johansen
Journal:  Eur J Appl Physiol       Date:  2002-04-26       Impact factor: 3.078

8.  A practical and transferable new protocol for treadmill testing of children and adults.

Authors:  Karl-Otto Dubowy; Winfried Baden; Stefan Bernitzki; Brigitte Peters
Journal:  Cardiol Young       Date:  2008-10-07       Impact factor: 1.093

9.  Noninvasive determination of cardiac output by the inert-gas-rebreathing method--comparison with cardiovascular magnetic resonance imaging.

Authors:  Joachim Saur; Stephan Fluechter; Frederik Trinkmann; Theano Papavassiliu; Stefan Schoenberg; Joerg Weissmann; Dariusch Haghi; Martin Borggrefe; Jens J Kaden
Journal:  Cardiology       Date:  2009-08-07       Impact factor: 1.869

10.  Self-estimated physical functioning poorly predicts actual exercise capacity in adolescents and adults with congenital heart disease.

Authors:  Alexander Gratz; John Hess; Alfred Hager
Journal:  Eur Heart J       Date:  2008-12-09       Impact factor: 29.983

View more
  8 in total

1.  Noninvasive measurement of cardiac output during exercise in children with tetralogy of Fallot.

Authors:  Elisa Marcuccio; Gaurav Arora; Eric Quivers; Mary Kay Yurchak; Francis McCaffrey
Journal:  Pediatr Cardiol       Date:  2012-03-17       Impact factor: 1.655

2.  Validation of cardiac output measurement by ultrasound dilution technique with pulmonary artery thermodilution in a pediatric animal model.

Authors:  Edward Darling; Naveen Thuramalla; Bruce Searles
Journal:  Pediatr Cardiol       Date:  2011-02-27       Impact factor: 1.655

3.  Noninvasive cardiac output measurement at rest and during exercise in pediatric patients after interventional or surgical atrial septal defect closure.

Authors:  Gesa Wiegand; Wolfhard Binder; Heidi Ulmer; Renate Kaulitz; Joachim Riethmueller; Michael Hofbeck
Journal:  Pediatr Cardiol       Date:  2012-02-22       Impact factor: 1.655

4.  Comparative Noninvasive Measurement of Cardiac Output Based on the Inert Gas Rebreathing Method (Innocor®) and MRI in Patients with Univentricular Hearts.

Authors:  Miriam Kuhn; Andreas Hornung; Heidi Ulmer; Christian Schlensak; Michael Hofbeck; Gesa Wiegand
Journal:  Pediatr Cardiol       Date:  2018-02-03       Impact factor: 1.655

5.  Validation of the Innocor device for noninvasive measurement of oxygen consumption in children and adults.

Authors:  Shreya S Sheth; Dawn M Maxey; Alice E Drain; Jeffrey A Feinstein
Journal:  Pediatr Cardiol       Date:  2012-10-30       Impact factor: 1.655

6.  Prognostic Value of Change in Cardiac Index After Prostacyclin Initiation in Pediatric Pulmonary Hypertension.

Authors:  Patrick D Evers; Paul J Critser; Michelle Cash; Melissa Magness; Russel Hirsch
Journal:  Pediatr Cardiol       Date:  2020-09-24       Impact factor: 1.655

7.  Optimizing target control of the vessel rich group with volatile anesthetics.

Authors:  Christopher W Connor
Journal:  J Clin Monit Comput       Date:  2018-06-21       Impact factor: 2.502

8.  Airway and alveolar nitric oxide production, lung function, and pulmonary blood flow in sickle cell disease.

Authors:  Alan Lunt; Na'eem Ahmed; Gerrard F Rafferty; Moira Dick; David Rees; Sue Height; Swee Lay Thein; Anne Greenough
Journal:  Pediatr Res       Date:  2015-10-22       Impact factor: 3.756

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.