Literature DB >> 19642059

Reliability of measurements with Innocor during exercise.

P Fontana1, U Boutellier, M Toigo.   

Abstract

Cardiac output represents the primary determinant of cardiovascular function. Therefore, understanding how cardiac output is regulated during exercise is crucial. A recently developed tool for determining cardiac output is the Innocor rebreathing system, which also incorporates an ergospirometry unit. So far, Innocor's test-retest reliability under exercise conditions has not been determined in healthy participants. Therefore, 15 male and 15 female healthy participants [30.6 y (SD 4.5); 68.0 kg (SD 10.5)] performed 2 test sessions, each consisting of 2 graded exercise tests to volitional exhaustion. We determined intra- and inter-session reliability of cardiac output, oxygen consumption, carbon dioxide output, and ventilation at 130 W and at peak exercise. For cardiac output, we found averaged coefficients of variation ranging from 4.3 (intra-session, 130 W) to 10.0% (inter-session, rest). For oxygen consumption, coefficients of variation ranged from 3.4 (intra-session, peak) to 5.7% (inter-session, peak). Coefficients of variation for carbon dioxide output were between 4.4 (intra-session, peak) and 6.6% (inter-session, peak), and for ventilation between 5.1 (intra-session, 130 W) and 7.0% (intra-session, peak). Innocor delivers safe and reliable measurements of cardiac output, gas exchange, and ventilation. Therefore, Innocor can be used to assess these parameters in exercise physiology studies as well as in performance diagnostics. Georg Thieme Verlag KG Stuttgart New York.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19642059     DOI: 10.1055/s-0029-1225340

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  20 in total

Review 1.  [Hemodynamics and physical capacity in patients with left ventricular assist devices : An overview].

Authors:  N Reiss; M Altesellmeier; S Mommertz; T Schmidt; S Schulte-Eistrup; D Willemsen
Journal:  Herz       Date:  2016-02-11       Impact factor: 1.443

2.  Non-invasive haemodynamic assessments using Innocor during standard graded exercise tests.

Authors:  Piero Fontana; Urs Boutellier; Marco Toigo
Journal:  Eur J Appl Physiol       Date:  2009-10-29       Impact factor: 3.078

3.  Biological aortic age derived from the arterial pressure waveform.

Authors:  Shigeki Shibata; Benjamin D Levine
Journal:  J Appl Physiol (1985)       Date:  2011-02-03

4.  A comparative evaluation of electrical velocimetry and inert gas rebreathing for the non-invasive assessment of cardiac output.

Authors:  Frederik Trinkmann; Manuel Berger; Ursula Hoffmann; Martin Borggrefe; Jens J Kaden; Joachim Saur
Journal:  Clin Res Cardiol       Date:  2011-07-01       Impact factor: 5.460

5.  Cardiac output with modified cardio-impedance against inert gas rebreathing during sub-maximal and maximal cycling exercise in healthy and fit subjects.

Authors:  Alessio Del Torto; Øyvind Skattebo; Jostein Hallén; Carlo Capelli
Journal:  Eur J Appl Physiol       Date:  2018-10-17       Impact factor: 3.078

6.  The impact of pulmonary disease on noninvasive measurement of cardiac output by the inert gas rebreathing method.

Authors:  Joachim Saur; Frederik Trinkmann; Christina Doesch; Armin Scherhag; Joachim Brade; Stefan O Schoenberg; Martin Borggrefe; Jens J Kaden; Theano Papavassiliu
Journal:  Lung       Date:  2010-07-31       Impact factor: 2.584

7.  Noninvasive measurement of cardiac output during exercise in children with tetralogy of Fallot.

Authors:  Elisa Marcuccio; Gaurav Arora; Eric Quivers; Mary Kay Yurchak; Francis McCaffrey
Journal:  Pediatr Cardiol       Date:  2012-03-17       Impact factor: 1.655

8.  Cardiac output but not stroke volume is similar in a Wingate and VO2peak test in young men.

Authors:  Piero Fontana; Katharina Betschon; Urs Boutellier; Marco Toigo
Journal:  Eur J Appl Physiol       Date:  2010-09-17       Impact factor: 3.078

9.  Noninvasive cardiac output determination for children by the inert gas-rebreathing method.

Authors:  Gesa Wiegand; Gunter Kerst; Winfried Baden; Michael Hofbeck
Journal:  Pediatr Cardiol       Date:  2010-10-13       Impact factor: 1.655

10.  Comparative Noninvasive Measurement of Cardiac Output Based on the Inert Gas Rebreathing Method (Innocor®) and MRI in Patients with Univentricular Hearts.

Authors:  Miriam Kuhn; Andreas Hornung; Heidi Ulmer; Christian Schlensak; Michael Hofbeck; Gesa Wiegand
Journal:  Pediatr Cardiol       Date:  2018-02-03       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.