Literature DB >> 19853946

Bedside capillary blood glucose measurements in critically ill patients: influence of catecholamine therapy.

M Fekih Hassen1, S Ayed, R Gharbi, H Ben Sik Ali, S Marghli, S Elatrous.   

Abstract

OBJECTIVE: To evaluate the effects of catecholamine therapy on the accuracy of capillary glucose measurements in hyperglycemic patients. PARTICIPANTS: 43 hyperglycemic patients older than 18 years admitted to the intensive care unit of a tertiary medical center were included from December 2005 to March 2006. MEASUREMENTS: This prospective study compares fingerstick and earlobe measurements simultaneously to sampled laboratory venous glucose in patients treated without (group 1) or with (group 2) catecholamine. Three venous samples for serum glucose analysis at three fixed hours and simultaneously two capillary glucose determinations were performed during the two first successive days after inclusion. A difference between the methods of glucose measurements greater than 2.3 mmol/l was considered significant.
RESULTS: The mean difference between the two methods was -0.05 mmol/l in group 1 and +0.29 mmol/l in group 2, while the limits of agreement were +4.03 and -4.13 mmol/l and +5.63 and -5.05 mmol/l in groups 1 and 2, respectively. A difference between paired measurements greater than 2.3 mmol/l was observed in 29% in group 1 and in 40% in group 2 (p=0.038). The alternative site did not improve the accuracy.
CONCLUSIONS: In critically ill patients treated with catecholamine capillary fingerstick blood glucose measurement seems inaccurate. Earlobe sampling does not improve accuracy. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19853946     DOI: 10.1016/j.diabres.2009.09.018

Source DB:  PubMed          Journal:  Diabetes Res Clin Pract        ISSN: 0168-8227            Impact factor:   5.602


  10 in total

1.  Impact of High-Dose Intravenous Vitamin C for Treatment of Sepsis on Point-of-Care Blood Glucose Readings.

Authors:  Anna Peyton Howell; Jenna L Parrett; Daniel R Malcom
Journal:  J Diabetes Sci Technol       Date:  2019-11-25

Review 2.  Accuracy of point-of-care glucose measurements.

Authors:  Annette Rebel; Mark A Rice; Brenda G Fahy
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

3.  The Japanese guidelines for the management of sepsis.

Authors:  Shigeto Oda; Mayuki Aibiki; Toshiaki Ikeda; Hitoshi Imaizumi; Shigeatsu Endo; Ryoichi Ochiai; Joji Kotani; Nobuaki Shime; Osamu Nishida; Takayuki Noguchi; Naoyuki Matsuda; Hiroyuki Hirasawa
Journal:  J Intensive Care       Date:  2014-10-28

4.  Accuracy of point-of-care blood glucose measurements in critically ill patients in shock.

Authors:  Carlo Jan Pati-An Garingarao; Myrna Buenaluz-Sedurante; Cecilia Alegado Jimeno
Journal:  J Diabetes Sci Technol       Date:  2014-06-08

5.  Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock, 2012.

Authors:  R P Dellinger; Mitchell M Levy; Andrew Rhodes; Djillali Annane; Herwig Gerlach; Steven M Opal; Jonathan E Sevransky; Charles L Sprung; Ivor S Douglas; Roman Jaeschke; Tiffany M Osborn; Mark E Nunnally; Sean R Townsend; Konrad Reinhart; Ruth M Kleinpell; Derek C Angus; Clifford S Deutschman; Flavia R Machado; Gordon D Rubenfeld; Steven Webb; Richard J Beale; Jean-Louis Vincent; Rui Moreno
Journal:  Intensive Care Med       Date:  2013-01-30       Impact factor: 17.440

6.  Accuracy of Blood Glucose Measurement and Blood Glucose Targets.

Authors:  Gert-Jan Eerdekens; Steffen Rex; Dieter Mesotten
Journal:  J Diabetes Sci Technol       Date:  2020-02-11

7.  Comparison of capillary and venous blood glucose levels using glucometer and laboratory blood glucose level in poisoned patients being in coma.

Authors:  Ahmad Yaraghi; Nastaran Eizadi Mood; Leila Kamali Dolatabadi
Journal:  Adv Biomed Res       Date:  2015-11-23

8.  Comparison of Space Glucose Control and Routine Glucose Management Protocol for Glycemic Control in Critically Ill Patients: A Prospective, Randomized Clinical Study.

Authors:  Biao Xu; Wei Jiang; Chun-Yao Wang; Li Weng; Xiao-Yun Hu; Jin-Min Peng; Bin Du
Journal:  Chin Med J (Engl)       Date:  2017-09-05       Impact factor: 2.628

9.  Development of a sensitive HPLC-MS/MS method for 25-hydroxyvitamin D2 and D3 measurement in capillary blood.

Authors:  XianTing Jiao; Yichun Yuan; Xirui Wang; Juan Li; Bin Liu; Tao Yuan; XiaoDan Yu
Journal:  J Clin Lab Anal       Date:  2020-06-26       Impact factor: 2.352

Review 10.  Accuracy of blood-glucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review.

Authors:  Shigeaki Inoue; Moritoki Egi; Joji Kotani; Kiyoshi Morita
Journal:  Crit Care       Date:  2013-03-18       Impact factor: 9.097

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.