Literature DB >> 19852801

Predictive factors for breast cancer in patients diagnosed atypical ductal hyperplasia at core needle biopsy.

Byung Joo Chae1, Ahwon Lee, Byung Joo Song, Sang Seol Jung.   

Abstract

BACKGROUND: Percutaneous core needle biopsy (CNB) is considered to be the standard technique for histological diagnosis of breast lesions. But, it is less reliable for diagnosing atypical ductal hyperplasia (ADH). The purpose of the present study was to predict, based on clinical and radiological findings, which cases of ADH diagnosed by CNB would be more likely to be associated with a more advanced lesion on subsequent surgical excision.
METHODS: Between February 2002 and December 2007, consecutive ultrasound-guided CNBs were performed on suspicious breast lesions at Seoul St. Mary's Hospital. A total of 69 CNBs led to a diagnosis of ADH, and 45 patients underwent follow-up surgical excision. We reviewed the medical records and analyses retrospectively.
RESULTS: Sixty-nine patients were diagnosed with ADH at CNB. Of these patients, 45 underwent surgical excision and 10 (22.2%) were subsequently diagnosed with a malignancy (ductal carcinoma in situ, n = 8; invasive cancer, n = 2). Univariate analysis revealed age (>or= 50-years) at the time of core needle biopsy (p = 0.006), size (> 10 mm) on imaging (p = 0.033), and combined mass with microcalcification on sonography (p = 0.029) to be associated with underestimation. When those three factors were included in multivariate analysis, only age (p = 0.035, HR 6.201, 95% CI 1.135-33.891) was an independent predictor of malignancy.
CONCLUSION: Age (>or= 50) at the time of biopsy is an independent predictive factor for breast cancer at surgical excision in patients with diagnosed ADH at CNB. For patients diagnosed with ADH at CNB, only complete surgical excision is the suitable treatment option, because we could not find any combination of factors that can safely predict the absence of DCIS or invasive cancer in a case of ADH.

Entities:  

Mesh:

Year:  2009        PMID: 19852801      PMCID: PMC2771003          DOI: 10.1186/1477-7819-7-77

Source DB:  PubMed          Journal:  World J Surg Oncol        ISSN: 1477-7819            Impact factor:   2.754


Background

Percutaneous core needle biopsy (CNB) is the standard technique for histological diagnosis of breast lesions. It has become the procedure of choice to investigate suspicious lesions of the breast and has been shown to be an effective means to rule out cancer, alleviating the cost and discomfort of surgery. Overall, CNB histological findings are in agreement with surgical biopsy in more than 95% of the cases [1-3]. But, CNB is less reliable for diagnosing atypical ductal hyperplasia (ADH). ADH is a proliferative lesion of the breast epithelium, which fulfils some but not all the criteria of low grade ductal carcinoma in situ (DCIS) [4]. ADH carries a 4-5 times increased risk of subsequent development of invasive carcinoma in either breast, [5,6] and there is genetic evidence in cell populations associated with cancer suggesting it may even be a direct precursor of malignancy[7]. Significant discordance has been reported isn CNB diagnosis of ADH, with 7%-87% of cases proving to be DCIS or invasive carcinoma on subsequent surgical excision [8-14]. This problem arises from the difficulty in differentiating between ADH and low grade DCIS on the small volume of tissue obtained from core biopsy [15]. In addition, foci of ADH may be present at the periphery of areas of DCIS [16] and, thus, even an unequivocal diagnosis of ADH does not preclude the presence of an adjacent and more advanced lesion. Because of this underestimation (which means presence of DCIS or invasive cancer) risk, some authors have recommended a mandatory surgical biopsy, while others have discussed options between surgery and follow-up [17]. Identification of patients with ADH diagnosed by CNB who can be spared surgical excision is an area of active investigation. However, the clinical, radiologic, and pathologic parameters on which to base this decision have not been consistently identified. The purpose of the present study was to predict, based on clinical and radiological findings, which cases of ADH diagnosed by CNB would be more likely to be associated with a more advanced lesion on subsequent surgical excision.

Materials and methods

Between February 2002 and December 2007, 3476 consecutive ultrasound-guided CNBs were performed on suspicious breast lesions at the Seoul St. Mary's Hospital. A total of 69 CNBs led to a diagnosis of ADH, and 45 patients underwent follow-up surgical excision. Seven patients refused surgical excision and were only followed up and 12 patients were transferred other hospital as per their request while 5 were lost to follow-up. The definition employed for "histological underestimation" was a lesion diagnosed as ADH at CNB that was revealed to harbor malignant foci at follow-up surgical excision, including DCIS and invasive cancer. All patients in this study underwent clinical and radiological examination, including mammography and ultrasound. The radiological appearance of the lesion was characterized according to the American College of Radiology Breast Imaging Reporting and Data System lexicon and the final assessment categories. All lesions were evaluated for size on imaging and presence of microcalcification. Lesion size was defined as the greatest dimension on ultrasound imaging for most patients, or mammography size for patients with microcalcification dominant lesions. Ultrasound-guided biopsies were used for sonographically visible lesions, and were performed with patients in a supine or decubitus position using high-resolution sonography. The biopsy was performed using a device with a 14-gauge automated needle or with an 11-gauge vacuum assisted biopsy device. The core biopsy tissue sections were fixed in 10% formaldehyde and embedded in paraffin. Each biopsy specimen was stained with hematoxylin and eosin. The biopsy slides were reviewed by experienced pathologists and diagnosed according to the ADH diagnostic criteria of the World Health Organization guidelines. The data were analyzed using Chi-square and logistic regression, as well as Fisher exact test for the small sample. P values < 0.05 were considered statistically significant.

Results

Sixty-nine patients were diagnosed with ADH at CNB. Of these, 45 underwent surgical excision at our institution. Of the 45 patients, 10 (22.2%) were diagnosed with a malignancy after surgical excision (DCIS, n = 8; invasive cancer, n = 2). Table 1 summarizes the underestimation rates and distribution in all patients according to clinical, radiological, and pathological variables, and compares the accurate diagnoses (n = 35) and underestimations (n = 10) according to patient, lesion, and biopsy variables. Six (13.3%) underwent 11-gauge stereotactic vacuum assisted biopsy because lesions were seen mainly by mammography rather than ultrasound. Women in the accurate diagnosis group were younger than those in the underestimation group (p = 0.003). Nine of the 39 ADH lesions (23.1%) found with 14-gauge automated gun biopsies were upgraded to carcinoma, and one of the six ADH lesions (16.7%) found with 11-gauge vacuum-assisted biopsies were upgraded to carcinoma. The underestimation rate for the 11-gauge vacuum-assisted biopsy (16.7%) was not significantly lower than that for the 14-gauge automated gun biopsy (23.1%) (p = 0.725).
Table 1

Pathologic results after surgical excision according to clinical, radiological and histological variables.

Pathology after excisionUnderestimationrate (22.2%)P value(Chi-square)

Benign (n = 35)Malignancy (n = 10)
Age (years)< 5028 (80%)3 (30%)9.7%0.003
≥507 (20%)7 (70%)50%
Mass on MMGYes10 (32.3%)4 (50%)28.6%0.351
No21 (67.7%)4 (50%)16%
MIC on MMGYes8 (25.8%)4 (50%)33.3%0.186
No23 (74.2%)4 (50%)14.8%
Mass + MIC on MMGYes1 (3.1%)2 (22.2%)66.7%0.52
No31 (96.9%)7 (77.8%)18.4%
Lesion size≤1 cm23 (69.7%)3 (30%)11.5%0.024
> 1 cm10 (30.3%)7 (70%)41.2%
Mass on USGYes27 (77.1%)9 (90%)25%0.370
No8 (22.9%)1 (0%)11.1%
MIC USGYes2 (5.7%)3 (30%)60%0.031
No33 (94.3%)7 (70%)17.5%
Mass + MIC on USGYes1 (2.9%)3 (30%)75%0.008
No34 (97.1%)7 (70%)17.1%
Needle size14 Gauge30 (85.7%)9 (90%)23.1%0.725
11 Gauge5 (14.3%)1 (0%)16.7%
Number of Cores≤ 530 (85.7%)8 (80%)21.1%0.660
> 55 (14.3%)2 (20%)28.6%

MMG: mammogram, MIC: microcalcification, USG: ultrasonography

Pathologic results after surgical excision according to clinical, radiological and histological variables. MMG: mammogram, MIC: microcalcification, USG: ultrasonography Univariate analysis revealed that age (≥ 50 years) at the time of core needle biopsy (p = 0.006), size on imaging (> 10 mm; p = 0.033), and combined mass with microcalcification on sonography (p = 0.029) were associated with underestimation (Table 2). When those three factors were included in multivariate analysis, only age at the time of core needle biopsy (p = 0.035, HR 6.201, 95% CI 1.135-33.891) was found to be an independent predictor of malignancy, whereas size on imaging and combined mass with microcalcification on sonography were negative predictors. (Table 3)
Table 2

Results of univariate analysis

HR95% CIP-value
Age9.3331.911-45.5830.006
Mass MMG2.10.434-10.1680.357
MIC MMG2.8750.579-14.2750.196
Mass + MIC MMG8.8570.701-111.9370.092
Lesion size5.3671.147-25.1050.033
Mass USG2.6670.292-24.3450.385
MIC USG4.5710.758-27.5770.097
Mass + MIC USG14.5711.315-161.4180.029
Needle size1.500.155-14.5570.727
Number of cores1.500.244-9.2190.662

HR: hazard ratio; CI: confidence interval; MMG: mammogram; MIC: microcalcification; USG: ultrasonography

Table 3

Results of Multivariate analysis.

HR95% CIP-value
Age6.2011.135-33.8910.035
Lesion size2.8780.474-17.4650.250
Mass + MIC USG4.5710.288-72.6090.281

HR: hazard ratio; CI: confidence interval; MMG: mammogram; MIC: microcalcification; USG: ultrasonography

Results of univariate analysis HR: hazard ratio; CI: confidence interval; MMG: mammogram; MIC: microcalcification; USG: ultrasonography Results of Multivariate analysis. HR: hazard ratio; CI: confidence interval; MMG: mammogram; MIC: microcalcification; USG: ultrasonography

Discussion

In the present study, clinico-pathological and radiological findings of ADH diagnosed by CNB were assessed to clarify predictors that could be useful in distinguishing between ADH and cancer containing DCIS. ADH is a borderline lesion on histology that is difficult to distinguish from low grade DCIS on the small tissue sample provided by CNB. Because of this difficulty, clinico-pathologic and radiologic findings that can help discriminate between ADH and DCIS are valuable in planning patient management. Although some variables like lesion size, combined mass, and microcalcification on sonography also tended to increased underestimation, only age at the time of biopsy (≥ 50 years) was presently determined to be an independent predictive factor for breast cancer at surgical excision in patients with diagnosed ADH at CNB. Consistent with our findings, Ko et al [18] observed an increase in underestimation rates in subjects aged 50 years and older, microcalcification on mammography and, lesion size > 15 mm. Several studies have examined various mammographic, clinical, and pathological factors that may predict the presence of a more significant lesion on surgical excision after a CNB diagnosis of ADH [12,19-21]. It is believed that the variability of cancer rates depends on the size and features of the mammographic lesion, size of the biopsy needle, extent and completeness of sampling of the mammographic target lesion, histological criteria used to diagnose ADH versus DCIS and/or usual hyperplasia, and the threshold for surgical excision. Use of vacuum assistance and more extensive sampling have improved the underestimation of carcinoma on surgical biopsy after a diagnosis of ADH on CNB from 33%-48% [2,21] to 7%-35% [14,22-25]. Although reduced underestimation with use of an 11-gauge vacuum-assisted device is explained by larger sample volumes, the number of specimens obtained presently appeared not to be correlated with a lower rate of underestimation. These results are similar to those of a previous study [12], in which the investigators found that specimen numbers per lesion did not correlate with underestimation, but that complete lesion removal did correlate with degree of underestimation. These findings indicate that targeting precision is more important than sample numbers. Further studies with more cases are needed to determine whether complete lesion removal at sonographically guided 11-gauge vacuum-assisted biopsy can reduce the rate of underestimation of ADH. Jackman et al, [26] recognized that as the maximum diameter of the mammographic lesion increased, so does the rate of ADH underestimation. Also, in the present study, lesion size on imaging of > 1 cm increased underestimation rates. However, lesion size was not an independent predictor upon multivariate analysis. Microcalcification with or without a mass has been reported to be the most common finding for both ADH (58% 88%) and DCIS (68% 98%) [8,27-29]. On histological examination, Helvie et al [10] found that the calcifications in mammary ducts within areas of ADH, without cell necrosis. In DCIS, the calcifications develop in secretions and are dystrophic calcifications secondary to necrotic tumor cells [30,31]. These histological differences could potentially be associated with different mammographic findings. But, those detailed variables were not addressed in the present study. Presently, only the combined sonographic finding of mass and microcalcifications was a significant predictive factor for underestimation in the univariate analysis. It has been suggested that microcalcification on mammography is an independent predictor of malignancy at follow-up surgical excision in patients diagnosed with ADH at CNB [18]. Our results did not reveal statistical significance in this regard. Limitations of the present study include its retrospective nature and that it did not involve a randomized series of patients. Furthermore, 24 (34.8%) of the 69 ADH cases did not undergo surgical excision and were therefore excluded. It is possible that cases with a lower possibility of malignancy were recommended for imaging follow-up rather than surgical excision, which could affect the underestimation rate and other results.

Conclusion

Only age at the time of biopsy (≥ 50 years) is an independent predictive factor for breast cancer at surgical excision in patients with diagnosed ADH at CNB. Identification of patients with ADH diagnosed by CNB who can be spared surgical excision is an area of active investigation. However, at present, clinical, radiologic, and pathologic factors on which to base this decision have not been consistently identified. So, for patients diagnosed with ADH at CNB, only complete surgical excision is a suitable treatment option because we could not find any combination of factors that can safely predict the absence of DCIS or invasive cancer in a case of ADH.

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

BJC carried out the statistical analysis, participated in the sequence alignment and drafted and described the manuscript. AL carried out the Pathologic diagnosis. BJS and SSJ conceived of the study, and participated in its design and coordination and helped to draft the manuscript. All authors read and approved the final manuscript.
  31 in total

1.  Mammographic appearance of ductal carcinoma in situ does not reliably predict histologic subtype.

Authors:  P J Slanetz; A A Giardino; T Oyama; F C Koerner; E F Halpern; R H Moore; D B Kopans
Journal:  Breast J       Date:  2001 Nov-Dec       Impact factor: 2.431

2.  Atypical ductal hyperplasia in breast core needle biopsies. Correlation of size of the lesion, complete removal of the lesion, and the incidence of carcinoma in follow-up biopsies.

Authors:  A A Renshaw; N Cartagena; R H Schenkman; R P Derhagopian; E W Gould
Journal:  Am J Clin Pathol       Date:  2001-07       Impact factor: 2.493

3.  Atypical ductal hyperplasia of the breast diagnosed by 11-gauge directional vacuum-assisted biopsy.

Authors:  Arvin Rao; Steve Parker; Erick Ratzer; Janet Stephens; Michael Fenoglio
Journal:  Am J Surg       Date:  2002-12       Impact factor: 2.565

4.  Atypical ductal hyperplasia and atypia of uncertain significance in core biopsies from mammographically detected lesions: correlation with excision diagnosis.

Authors:  Jennet M Harvey; Gregory F Sterrett; Felicity A Frost
Journal:  Pathology       Date:  2002-10       Impact factor: 5.306

5.  Core biopsy of the breast with atypical ductal hyperplasia: a probabilistic approach to reporting.

Authors:  K A Ely; B A Carter; R A Jensen; J F Simpson; D L Page
Journal:  Am J Surg Pathol       Date:  2001-08       Impact factor: 6.394

6.  Association of breast cancer with the finding of atypical ductal hyperplasia at core breast biopsy.

Authors:  M M Moore; C W Hargett; J B Hanks; L L Fajardo; J A Harvey; H F Frierson; C L Slingluff
Journal:  Ann Surg       Date:  1997-06       Impact factor: 12.969

7.  Atypical ductal hyperplasia and ductal carcinoma in situ as revealed by large-core needle breast biopsy: results of surgical excision.

Authors:  M L Darling; D N Smith; S C Lester; C Kaelin; D L Selland; C M Denison; P J DiPiro; D I Rose; E Rhei; J E Meyer
Journal:  AJR Am J Roentgenol       Date:  2000-11       Impact factor: 3.959

8.  Is surgical excision necessary for atypical ductal hyperplasia of the breast diagnosed by Mammotome?

Authors:  G Adrales; P Turk; T Wallace; R Bird; H J Norton; F Greene
Journal:  Am J Surg       Date:  2000-10       Impact factor: 2.565

9.  Vacuum-assisted stereotactic breast biopsy: histologic underestimation of malignant lesions.

Authors:  W E Burak; K E Owens; M B Tighe; L Kemp; S A Dinges; C L Hitchcock; J Olsen
Journal:  Arch Surg       Date:  2000-06

10.  Atypical ductal hyperplasia: can some lesions be defined as probably benign after stereotactic 11-gauge vacuum-assisted biopsy, eliminating the recommendation for surgical excision?

Authors:  Roger J Jackman; Robyn L Birdwell; Debra M Ikeda
Journal:  Radiology       Date:  2002-08       Impact factor: 11.105

View more
  16 in total

1.  Early Breast Cancer Precursor Lesions: Lessons Learned from Molecular and Clinical Studies.

Authors:  Hans-Peter Sinn; Zeinab Elsawaf; Birgit Helmchen; Sebastian Aulmann
Journal:  Breast Care (Basel)       Date:  2010-08-23       Impact factor: 2.860

2.  Surgical implications and variability in the use of the flat epithelial atypia diagnosis on breast biopsy specimens.

Authors:  Laura S Samples; Mara H Rendi; Paul D Frederick; Kimberly H Allison; Heidi D Nelson; Thomas R Morgan; Donald L Weaver; Joann G Elmore
Journal:  Breast       Date:  2017-05-03       Impact factor: 4.380

3.  Upgrade of high-risk breast lesions detected on mammography in the Breast Cancer Surveillance Consortium.

Authors:  Tehillah S Menes; Robert Rosenberg; Steven Balch; Shabnam Jaffer; Karla Kerlikowske; Diana L Miglioretti
Journal:  Am J Surg       Date:  2013-10-07       Impact factor: 2.565

4.  The risk of upgrade for atypical ductal hyperplasia detected on magnetic resonance imaging-guided biopsy: a study of 100 cases from four academic institutions.

Authors:  Thaer Khoury; Zaibo Li; Souzan Sanati; Mohamed M Desouki; Xiwei Chen; Dan Wang; Song Liu; Rouzan Karabakhtsian; Prasanna Kumar; Beatriu Reig
Journal:  Histopathology       Date:  2015-10-05       Impact factor: 5.087

Review 5.  Upgrade rates of high-risk breast lesions diagnosed on core needle biopsy: a single-institution experience and literature review.

Authors:  Kelly L Mooney; Lawrence W Bassett; Sophia K Apple
Journal:  Mod Pathol       Date:  2016-08-19       Impact factor: 7.842

6.  Follow-up of breast papillary lesion on core needle biopsy: experience in African-American population.

Authors:  He Wang; Patricia Tsang; Cyril D'Cruz; Kevin Clarke
Journal:  Diagn Pathol       Date:  2014-04-24       Impact factor: 2.644

7.  Mapping breast tissue types by miniature radio-frequency near-field spectroscopy sensor in ex-vivo freshly excised specimens.

Authors:  Zvi Kaufman; Haim Paran; Ilana Haas; Patricia Malinger; Tania Zehavi; Tamar Karni; Izhak Pappo; Judith Sandbank; Judith Diment; Tanir Allweis
Journal:  BMC Med Imaging       Date:  2016-10-10       Impact factor: 1.930

8.  The ratio of atypical ductal hyperplasia foci to core numbers in needle biopsy: a practical index predicting breast cancer in subsequent excision.

Authors:  Jeong-Ju Lee; Hee Jin Lee; Jun Kang; Jeong-Hyeon Jo; Gyungyub Gong
Journal:  Korean J Pathol       Date:  2012-02-23

9.  Validation of a scoring system for predicting malignancy in patients diagnosed with atypical ductal hyperplasia using an ultrasound-guided core needle biopsy.

Authors:  Jisun Kim; Wonshik Han; Eun-Young Go; Hyeong-Gon Moon; Soo Kyung Ahn; Hee-Chul Shin; Jee-Man You; Jung Min Chang; Nariya Cho; Woo Kyung Moon; In Ae Park; Dong-Young Noh
Journal:  J Breast Cancer       Date:  2012-12-31       Impact factor: 3.588

10.  First International Consensus Conference on lesions of uncertain malignant potential in the breast (B3 lesions).

Authors:  Christoph J Rageth; Elizabeth Am O'Flynn; Christopher Comstock; Claudia Kurtz; Rahel Kubik; Helmut Madjar; Domenico Lepori; Gert Kampmann; Alexander Mundinger; Astrid Baege; Thomas Decker; Stefanie Hosch; Christoph Tausch; Jean-François Delaloye; Elisabeth Morris; Zsuzsanna Varga
Journal:  Breast Cancer Res Treat       Date:  2016-08-13       Impact factor: 4.872

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.