Literature DB >> 19852656

The validity of in vivo tooth volume determinations from cone-beam computed tomography.

Yi Liu1, Raphael Olszewski, Emanuel Stefan Alexandroni, Reyes Enciso, Tianmin Xu, James K Mah.   

Abstract

OBJECTIVE: To determine the accuracy of volumetric analysis of teeth in vivo using cone-beam computed tomography (CBCT).
MATERIALS AND METHODS: The physical volume (Vw) of 24 bicuspids extracted for orthodontic purposes (16 were imaged with the I-CAT and 8 with the CB MercuRay) were determined using the water displacement technique. Corresponding pretreatment CBCT image data were uploaded into Amira 4.0 for segmentation and radiographic volume (Va). All measurements were performed twice by two observers. The statistical difference between Vw and Va was assessed using a paired t-test. The intraobserver and interobserver reliability were determined by calculating Pearson correlation coefficients and intraclass correlation coefficients.
RESULTS: The overall mean Vw of teeth specimens was 0.553 +/- 0.082 cm3, while the overall mean Va was 0.548 +/- 0.079 cm3 (0.529 +/- 0.078 cm3 for observer 1 and 0.567 +/- 0.085 cm3 for observer 2). There were statistically significant differences between Va and Vw (P < .05). Between observer 1 and observer 2, Va measurements were statistically significantly different (P < .05). The interobserver and intraobserver correlation coefficient for Vw was high. Lastly, surface smoothing reduced the volume by 3% to 12%.
CONCLUSIONS: In vivo determination of tooth volumes from CBCT data is feasible. The measurements slightly deviate from the physical volumes within -4% to 7%. Smoothing operations reduce volume measurements. Currently, no requirements for accuracy of volumetric determinations of tooth volume have been established.

Entities:  

Mesh:

Year:  2010        PMID: 19852656      PMCID: PMC8978733          DOI: 10.2319/121608-639.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  25 in total

1.  Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters.

Authors:  S Prevrhal; K Engelke; W A Kalender
Journal:  Phys Med Biol       Date:  1999-03       Impact factor: 3.609

2.  A new technique for the creation of a computerized composite skull model.

Authors:  Jaime Gateno; James Xia; John F Teichgraeber; Andrew Rosen
Journal:  J Oral Maxillofac Surg       Date:  2003-02       Impact factor: 1.895

3.  Three-dimensional craniofacial imaging.

Authors:  James Mah; David Hatcher
Journal:  Am J Orthod Dentofacial Orthop       Date:  2004-09       Impact factor: 2.650

4.  Accuracy in measurement of distance using limited cone-beam computerized tomography.

Authors:  Kaoru Kobayashi; Shinji Shimoda; Yoichi Nakagawa; Akira Yamamoto
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Mar-Apr       Impact factor: 2.804

5.  Cone-beam computed tomography in orthodontics: benefits and limitations.

Authors:  Christof Holberg; Stefanie Steinhäuser; Phillip Geis; Ingrid Rudzki-Janson
Journal:  J Orofac Orthop       Date:  2005-11       Impact factor: 1.938

6.  Usefulness of computed tomography in pre-surgical evaluation of maxillo-facial pathology with rapid prototyping and surgical pre-planning by virtual reality.

Authors:  Francesco Toso; Chiara Zuiani; Maurizio Vergendo; Iolanda Salvo; Massimo Robiony; Massimo Politi; Massimo Bazzocchi
Journal:  Radiol Med       Date:  2005 Nov-Dec       Impact factor: 3.469

7.  The evolution of digital study models.

Authors:  James Mah
Journal:  J Clin Orthod       Date:  2007-09

8.  In vitro analysis of the accuracy of subtraction radiography and computed tomography scanning for determination of bone graft volume.

Authors:  J Jensen; J Kragskov; A Wenzel; S Sindet-Pedersen
Journal:  J Oral Maxillofac Surg       Date:  1998-06       Impact factor: 1.895

9.  A meta-analysis of normal ranges for root surface areas of the permanent dentition.

Authors:  P P Hujoel
Journal:  J Clin Periodontol       Date:  1994-04       Impact factor: 8.728

10.  Root surface measurements of mandibular molars using stereophotogrammetry.

Authors:  R W Anderson; H E McGarrah; R D Lamb; J D Eick
Journal:  J Am Dent Assoc       Date:  1983-10       Impact factor: 3.634

View more
  17 in total

1.  The effect of slice thickness on the assessment of bone defect volumes by the Cavalieri principle using cone beam computed tomography.

Authors:  Omer Said Sezgin; Saadettin Kayıpmaz; Bunyamin Sahin
Journal:  J Digit Imaging       Date:  2013-02       Impact factor: 4.056

2.  Automated implant segmentation in cone-beam CT using edge detection and particle counting.

Authors:  Ruben Pauwels; Reinhilde Jacobs; Hilde Bosmans; Pisha Pittayapat; Pasupen Kosalagood; Onanong Silkosessak; Soontra Panmekiate
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-07       Impact factor: 2.924

3.  Influence of CBCT parameters on the output of an automatic edge-detection-based endodontic segmentation.

Authors:  J Michetti; M Georgelin-Gurgel; J-P Mallet; F Diemer; K Boulanouar
Journal:  Dentomaxillofac Radiol       Date:  2015-06-02       Impact factor: 2.419

4.  Accuracy of ITK-SNAP software for 3D analysis of a non-regular topography structure.

Authors:  Amanda Farias Gomes; Danieli Moura Brasil; Amaro Ilídio Vespasiano Silva; Deborah Queiroz Freitas; Francisco Haiter-Neto; Francisco Carlos Groppo
Journal:  Oral Radiol       Date:  2019-07-02       Impact factor: 1.852

5.  Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT.

Authors:  D Maret; N Telmon; O A Peters; B Lepage; J Treil; J M Inglèse; A Peyre; J L Kahn; M Sixou
Journal:  Dentomaxillofac Radiol       Date:  2012-12       Impact factor: 2.419

6.  Assessment of automatic segmentation of teeth using a watershed-based method.

Authors:  Antoine Galibourg; Jean Dumoncel; Norbert Telmon; Adèle Calvet; Jérôme Michetti; Delphine Maret
Journal:  Dentomaxillofac Radiol       Date:  2017-11-01       Impact factor: 2.419

7.  Influence of periapical lesion size on healing outcome following regenerative endodontic procedures: a clinical investigation.

Authors:  Noha Mohamed El Kateb; Mahmoud Mostafa Fata
Journal:  Oral Radiol       Date:  2021-11-26       Impact factor: 1.882

8.  A novel stereoscopic projection display system for CT images of fractures.

Authors:  Xiujuan Liu; Hong Jiang; Yuedong Lang; Hongbo Wang; Na Sun
Journal:  Exp Ther Med       Date:  2013-04-03       Impact factor: 2.447

9.  From 2D to 3D: Construction of a 3D Parametric Model for Detection of Dental Roots Shape and Position from a Panoramic Radiograph-A Preliminary Report.

Authors:  Laura Mazzotta; Mauro Cozzani; Armando Razionale; Sabrina Mutinelli; Attilio Castaldo; Armando Silvestrini-Biavati
Journal:  Int J Dent       Date:  2013-03-11

10.  Evaluation of mandibular volume using cone-beam computed tomography and correlation with cephalometric values.

Authors:  Koshu Katayama; Tetsutaro Yamaguchi; Mami Sugiura; Shugo Haga; Koutaro Maki
Journal:  Angle Orthod       Date:  2013-08-28       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.