Optimal stent-sizing with intravascular ultrasound contributes to complete neointimal coverage after sirolimus-eluting stent implantation assessed by angioscopy.

Fusako Sera1, Masaki Awata, Masaaki Uematsu, Jun-ichi Kotani, Shinsuke Nanto, Seiki Nagata.   

Abstract

OBJECTIVES: The aim of this study was to explore the determinants of neointimal coverage after sirolimus-eluting stent (SES).
BACKGROUND: Although SES has significantly reduced in-stent restenosis by inhibiting neointimal hyperplasia, insufficient neointimal coverage after stenting might result in adverse outcomes.
METHODS: We evaluated 28 SES lesions with both angioscopy and intravascular ultrasound (IVUS). Quantitative assessments of the lesions and stent expansion were performed by IVUS at the time of stent implantation, and degree of neointimal coverage was judged by angioscopy at follow-up (11 +/- 6 months) whether the stent struts were embedded by the neointima ("complete/incomplete" neointimal coverage).
RESULTS: "Complete" coverage was identified in 10 (36%), and "incomplete" coverage was identified in 18 (64%). Time from the stenting to angioscopy as well as the lesion and procedural characteristics were similar between the complete and incomplete coverage groups. The IVUS parameters were also similar, except for the final minimum stent cross-sectional area (CSA) (7.0 +/- 1.8 mm(2) in complete vs. 5.3 +/- 1.9 mm(2) in incomplete, p = 0.02) and lumen CSA at the distal reference site (6.1 +/- 1.4 mm(2) in complete vs. 4.9 +/- 1.2 mm(2) in incomplete, p = 0.02). The ratio of the stent area to the vessel area was significantly larger in the complete coverage than in the incomplete coverage group (0.52 +/- 0.11 vs. 0.39 +/- 0.09, p = 0.002).
CONCLUSIONS: Adequate stent sizing relative to the vessel size might contribute to the angioscopically complete neointimal coverage after SES implantation.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19850260     DOI: 10.1016/j.jcin.2009.07.006

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  8 in total

1.  Complete disappearance of red thrombi in a drug-eluting stent despite discontinuation of antiplatelet therapy: Angioscopic confirmation.

Authors:  Daisuke Murakami; Masamichi Takano; Masanori Yamamoto; Nobuaki Kobayashi; Shinya Yokoyama; Yoshihiko Seino; Kyoichi Mizuno
Journal:  J Cardiol Cases       Date:  2011-11-03

2.  Calibration-free device sizing using an inverse geometry x-ray system.

Authors:  Michael T Tomkowiak; Michael A Speidel; Amish N Raval; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

3.  A higher colour grade yellow plaque was detected at one year after implantation of an everolimus-eluting stent than after a zotarolimus-eluting stent.

Authors:  Koshi Matsuo; Yasunori Ueda; Mayu Nishio; Akio Hirata; Mitsutoshi Asai; Takayoshi Nemoto; Ayaka Murakami; Kazunori Kashiwase; Kazuhisa Kodama
Journal:  Heart Asia       Date:  2013-09-07

4.  Expert Opinion: Optimising Stent Deployment in Contemporary Practice: The Role of Intracoronary Imaging and Non-compliant Balloons.

Authors:  Ashok Seth; Sajal Gupta; Vivudh Pratap Singh; Vijay Kumar
Journal:  Interv Cardiol       Date:  2017-09

5.  Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  J Med Imaging (Bellingham)       Date:  2014-10

Review 6.  Optical coherence tomography endpoints in stent clinical investigations: strut coverage.

Authors:  Satoko Tahara; Daniel Chamié; Motaz Baibars; Chadi Alraies; Marco Costa
Journal:  Int J Cardiovasc Imaging       Date:  2011-03-11       Impact factor: 2.357

7.  Calibration-Free Coronary Artery Measurements for Interventional Device Sizing using Inverse Geometry X-ray Fluoroscopy: In Vivo Validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19

8.  Vascular Response to Experimental Stent Malapposition and Under-Expansion.

Authors:  Caroline C O'Brien; Augusto C Lopes; Kumaran Kolandaivelu; Mie Kunio; Jonathan Brown; Vijaya B Kolachalama; Claire Conway; Lynn Bailey; Peter Markham; Marco Costa; James Ware; Elazer R Edelman
Journal:  Ann Biomed Eng       Date:  2016-01-05       Impact factor: 3.934

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.