Literature DB >> 19846124

Transcatheter aortic valve implantation for high-risk patients with severe aortic stenosis: A systematic review.

Tristan D Yan1, Christopher Cao, Julie Martens-Nielsen, Ratnasari Padang, Martin Ng, Michael P Vallely, Paul G Bannon.   

Abstract

OBJECTIVES: The present systematic review objectively assessed the safety and clinical effectiveness of transcatheter aortic valve implantation for patients at high surgical risk with severe aortic stenosis.
METHODS: Electronic searches were performed in 6 databases from January 2000 to March 2009. The end points included feasibility, safety, efficacy, and durability. Clinical effectiveness was synthesized through a narrative review with full tabulation of results of all included studies.
RESULTS: The current evidence on transcatheter aortic valve implantation for aortic stenosis is limited to short-term observational studies. The overall procedural success rates ranged from 74% to 100%. The incidence of major adverse events included 30-day mortality (0%-25%), major ventricular tachyarrhythmia (0%-4%), myocardial infarction (0%-15%), cardiac tamponade (2%-10%), stroke (0%-10%), conversion to surgery (0%-8%), moderate to major paravalvular leak (4%-35%), vascular complication (8%-17%), valve-in-valve procedure (2%-12%), and aortic dissection/perforation (0%-4%). The overall 30-day major adverse cardiovascular and cerebral events ranged from 3% to 35%. The mean aortic valve area ranged from 0.5 to 0.8 cm(2) before and 1.3 to 2.0 cm(2) after transcatheter aortic valve implantation. The mean pressure gradient ranged from 34 to 58 mm Hg before and 3 to 12 mm Hg after transcatheter aortic valve implantation. There was no significant deterioration in echocardiography measurements during the assessment period. Death rate at 6 months postprocedure ranged from 18% to 48%. No studies had adequate follow-up to reliably evaluate long-term outcomes.
CONCLUSIONS: The procedure has a potential for serious complications. Although short-term efficacy based on echocardiography measurements is good, there is little evidence on long-term outcomes. The use of transcatheter aortic valve implantation should be considered only within the boundaries of clinical trials. Copyright 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19846124     DOI: 10.1016/j.jtcvs.2009.08.037

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  17 in total

1.  Aortic valve prosthesis tracking for transapical aortic valve implantation.

Authors:  M E Karar; D R Merk; C Chalopin; T Walther; V Falk; O Burgert
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-09-16       Impact factor: 2.924

2.  There are two sides to everything: two case reports on sequelae of rescue interventions to treat complications of transcatheter aortic valve implantation of the Medtronic CoreValve prosthesis.

Authors:  Ralf Zahn; Rudolf Schiele; Caroline Kilkowski; Bärbel Klein; Uwe Zeymer; Christiane Werling; Andreas Lehmann; Günter Layer; Werner Saggau
Journal:  Clin Res Cardiol       Date:  2010-04-20       Impact factor: 5.460

Review 3.  Transcatheter aortic valve implantation: evidence on safety and efficacy compared with medical therapy. A systematic review of current literature.

Authors:  L Figulla; A Neumann; H R Figulla; P Kahlert; R Erbel; T Neumann
Journal:  Clin Res Cardiol       Date:  2010-12-17       Impact factor: 5.460

4.  A systematic review of transapical aortic valve implantation.

Authors:  Mohammad Rahnavardi; Jaime Santibanez; Karan Sian; Tristan D Yan
Journal:  Ann Cardiothorac Surg       Date:  2012-07

5.  Intraoperative tracking of aortic valve plane.

Authors:  D L H Nguyen; M Garreau; V Auffret; H Le Breton; J P Verhoye; P Haigron
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

Review 6.  Vascular access in transcatheter aortic valve implantation.

Authors:  Vasco da Gama Ribeiro; Luis Vouga; Alan Markowitz; Hiram G Bezerra; Pedro Braga; Muhammad Ansari; Daniel Leite; Joao Rocha; Monica Carvalho; Daniel I Simon; Marco A Costa
Journal:  Int J Cardiovasc Imaging       Date:  2011-08-31       Impact factor: 2.357

7.  Incidence rate and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis.

Authors:  Valeria Calvi; Sergio Conti; Giusi Paola Pruiti; Davide Capodanno; Euglena Puzzangara; Donatella Tempio; Angelo Di Grazia; Gian Paolo Ussia; Corrado Tamburino
Journal:  J Interv Card Electrophysiol       Date:  2011-11-26       Impact factor: 1.900

8.  Computer Vision Techniques for Transcatheter Intervention.

Authors:  Feng Zhao; Xianghua Xie; Matthew Roach
Journal:  IEEE J Transl Eng Health Med       Date:  2015-06-18       Impact factor: 3.316

Review 9.  Aortic regurgitation after transcatheter aortic valve implantation: mechanisms and implications.

Authors:  Barbara E Stähli; Willibald Maier; Roberto Corti; Thomas F Lüscher; Rolf Jenni; Felix C Tanner
Journal:  Cardiovasc Diagn Ther       Date:  2013-03

10.  Aortic valve stenosis after previous coronary bypass: transcatheter valve implantation or aortic valve replacement?

Authors:  Olivier Jegaden; Joel Lapeze; Fadi Farhart; Guy de Gevigney
Journal:  J Cardiothorac Surg       Date:  2012-05-29       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.