Literature DB >> 24110703

Intraoperative tracking of aortic valve plane.

D L H Nguyen, M Garreau, V Auffret, H Le Breton, J P Verhoye, P Haigron.   

Abstract

The main objective of this work is to track the aortic valve plane in intra-operative fluoroscopic images in order to optimize and secure Transcatheter Aortic Valve Implantation (TAVI) procedure. This paper is focused on the issue of aortic valve calcifications tracking in fluoroscopic images. We propose a new method based on the Tracking-Learning-Detection approach, applied to the aortic valve calcifications in order to determine the position of the aortic valve plane in intra-operative TAVI images. This main contribution concerns the improvement of object detection by updating the recursive tracker in which all features are tracked jointly. The approach has been evaluated on four patient databases, providing an absolute mean displacement error less than 10 pixels (≈2mm). Its suitability for the TAVI procedure has been analyzed.

Entities:  

Mesh:

Year:  2013        PMID: 24110703      PMCID: PMC3900434          DOI: 10.1109/EMBC.2013.6610516

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

Review 1.  Transcatheter aortic valve implantation for high-risk patients with severe aortic stenosis: A systematic review.

Authors:  Tristan D Yan; Christopher Cao; Julie Martens-Nielsen; Ratnasari Padang; Martin Ng; Michael P Vallely; Paul G Bannon
Journal:  J Thorac Cardiovasc Surg       Date:  2009-10-28       Impact factor: 5.209

2.  Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description.

Authors:  Alain Cribier; Helene Eltchaninoff; Assaf Bash; Nicolas Borenstein; Christophe Tron; Fabrice Bauer; Genevieve Derumeaux; Frederic Anselme; François Laborde; Martin B Leon
Journal:  Circulation       Date:  2002-12-10       Impact factor: 29.690

3.  Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve.

Authors:  Martyn Thomas; Gerhard Schymik; Thomas Walther; Dominique Himbert; Thierry Lefèvre; Hendrik Treede; Holger Eggebrecht; Paolo Rubino; Iassen Michev; Rüdiger Lange; William N Anderson; Olaf Wendler
Journal:  Circulation       Date:  2010-06-21       Impact factor: 29.690

  3 in total
  1 in total

1.  Context region discovery for automatic motion compensation in fluoroscopy.

Authors:  Yin Xia; Sarfaraz Hussein; Vivek Singh; Matthias John; Ying Wu; Terrence Chen
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-26       Impact factor: 2.924

  1 in total