Continuous measurement of cardiac output during aortic cross-clamping by the oesophageal Doppler monitor ODM 1.

K F Klotz1, S Klingsiek, M Singer, H Wenk, S Eleftheriadis, H Kuppe, P Schmucker.   

Abstract

We have compared the Doppler against the thermodilution technique for measurement of cardiac output in six patients during aortic surgery. The correlation coefficient between the two methods was between 0.76 and 0.84 during the different periods of the operation. Using the integral nomogram instead of direct calibration, the Doppler system underestimated cardiac output in atherosclerotic patients. However, the Doppler method did register accurately significant changes in cardiac output.

Entities:  

Mesh:

Year:  1995        PMID: 7640119     DOI: 10.1093/bja/74.6.655

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  7 in total

1.  What's in a beat?

Authors:  Mervyn Singer
Journal:  Intensive Care Med       Date:  2003-10       Impact factor: 17.440

Review 2.  Transesophageal Doppler devices: A technical review.

Authors:  Patrick Schober; Stephan A Loer; Lothar A Schwarte
Journal:  J Clin Monit Comput       Date:  2009-10-20       Impact factor: 2.502

3.  Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients.

Authors:  J Y Lefrant; P Bruelle; A G Aya; G Saïssi; M Dauzat; J E de La Coussaye; J J Eledjam
Journal:  Intensive Care Med       Date:  1998-04       Impact factor: 17.440

Review 4.  The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults.

Authors:  Paul M Dark; Mervyn Singer
Journal:  Intensive Care Med       Date:  2004-09-11       Impact factor: 17.440

5.  Effect of different analgesic techniques on hemodynamic variables recorded with an esophageal Doppler monitor during ovariohysterectomy in dogs.

Authors:  Ignacio Sández; María Soto; Daniel Torralbo; Eva Rioja
Journal:  Can Vet J       Date:  2018-04       Impact factor: 1.008

6.  A novel method of trans-esophageal Doppler cardiac output monitoring utilizing peripheral arterial pulse contour with/without machine learning approach.

Authors:  Kazunori Uemura; Takuya Nishikawa; Toru Kawada; Can Zheng; Meihua Li; Keita Saku; Masaru Sugimachi
Journal:  J Clin Monit Comput       Date:  2021-02-17       Impact factor: 2.502

Review 7.  Clinical review: New technologies -- venturing out of the intensive care unit.

Authors:  Ronny Otero; A Joseph Garcia
Journal:  Crit Care       Date:  2004-11-02       Impact factor: 9.097

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.