Literature DB >> 19819750

Reliability, validity, and precision of an active stereophotogrammetry system for three-dimensional evaluation of the human torso.

Scott M Paul1, Andrew P Chamberlin, Charles Hatt, Amritha V Nayak, Jerome V Danoff.   

Abstract

To determine the reliability, stability, validity and precision of a stereophotogrammetry (SP) system for use in quantifying the complex three-dimensional structure of the human torso, we performed assessments of the system using images of geometric solids and a human-form mannequin. Analysis of geometric solids revealed excellent intra- and interrater reliability of the system for linear, surface area and volume measurements (r>0.99, P<0.001). Overall, no significant difference was found between SP and manual measurements (F=4.23, P>0.06). The system exhibited excellent stability in images of the mannequin over time (r>0.99). The limit of precision (error>5%) of the system to detect objects on the surface of the mannequin was estimated at an object size of 23.5cm(2) for surface area and 32mL for volume. These results demonstrate the capability of SP of the torso to be used as a reliable, stable and valid measure of torso morphology to be applied as a clinical outcome tool in studies of bony and soft tissue pathologies such as scoliosis, rib deformities, obesity or edema.

Entities:  

Mesh:

Year:  2009        PMID: 19819750      PMCID: PMC3502070          DOI: 10.1016/j.medengphy.2009.08.011

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  14 in total

1.  A stereo-photogrammetric method to measure the facial dysmorphology of children in the diagnosis of fetal alcohol syndrome.

Authors:  E M Meintjes; T S Douglas; F Martinez; C L Vaughan; L P Adams; A Stekhoven; D Viljoen
Journal:  Med Eng Phys       Date:  2002-12       Impact factor: 2.242

2.  Symmetrical breast reconstruction: is there a role for three-dimensional digital photography?

Authors:  Maurice Y Nahabedian; Gregory Galdino
Journal:  Plast Reconstr Surg       Date:  2003-11       Impact factor: 4.730

3.  Comparison of Cobb angles measured manually, calculated from 3-D spinal reconstruction, and estimated from torso asymmetry.

Authors:  Jacob L Jaremko; Philippe Poncet; Janet Ronsky; James Harder; Jean Dansereau; Hubert Labelle; Ronald F Zernicke
Journal:  Comput Methods Biomech Biomed Engin       Date:  2002-08       Impact factor: 1.763

4.  Clinical applications of three-dimensional photography in breast surgery.

Authors:  Greg M Galdino; Maurice Nahabedian; Michael Chiaramonte; Jason Z Geng; Stanley Klatsky; Paul Manson
Journal:  Plast Reconstr Surg       Date:  2002-07       Impact factor: 4.730

5.  Validity and reliability of an alginate method to measure body surface area.

Authors:  Joo-Young Lee; Jeong-Wha Choi
Journal:  J Physiol Anthropol       Date:  2006-05       Impact factor: 2.867

6.  Anthropometric precision and accuracy of digital three-dimensional photogrammetry: comparing the Genex and 3dMD imaging systems with one another and with direct anthropometry.

Authors:  Seth M Weinberg; Sybill Naidoo; Daniel P Govier; Rick A Martin; Alex A Kane; Mary L Marazita
Journal:  J Craniofac Surg       Date:  2006-05       Impact factor: 1.046

7.  An objective evaluation of breast symmetry and shape differences using 3-dimensional images.

Authors:  Albert Losken; Inessa Fishman; Donald D Denson; Hunter R Moyer; Grant W Carlson
Journal:  Ann Plast Surg       Date:  2005-12       Impact factor: 1.539

8.  Validating three-dimensional imaging of the breast.

Authors:  Albert Losken; Hisham Seify; Donald D Denson; Alfredo A Paredes; Grant W Carlson
Journal:  Ann Plast Surg       Date:  2005-05       Impact factor: 1.539

9.  The three dimensional reconstruction and monitoring of facial surfaces.

Authors:  A Gregory; R T Lipczynski
Journal:  Med Eng Phys       Date:  1994-05       Impact factor: 2.242

10.  Reliability of trunk shape measurements based on 3-D surface reconstructions.

Authors:  Valérie Pazos; Farida Cheriet; Jean Danserau; Janet Ronsky; Ronald F Zernicke; Hubert Labelle
Journal:  Eur Spine J       Date:  2007-08-15       Impact factor: 3.134

View more
  2 in total

1.  Digital stereophotogrammetry as a new technique to quantify truncal deformity: a pilot study in persons with osteogenesis imperfecta.

Authors:  Lisa R Gabor; Andrew P Chamberlin; Ellen Levy; Monique B Perry; Holly Cintas; Scott M Paul
Journal:  Am J Phys Med Rehabil       Date:  2011-10       Impact factor: 2.159

2.  Accuracy of Portable Face-Scanning Devices for Obtaining Three-Dimensional Face Models: A Systematic Review and Meta-Analysis.

Authors:  Hang-Nga Mai; Jaeil Kim; Youn-Hee Choi; Du-Hyeong Lee
Journal:  Int J Environ Res Public Health       Date:  2020-12-25       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.