High-resolution fluid-structure interaction simulations of flow through a bi-leaflet mechanical heart valve in an anatomic aorta.

Iman Borazjani1, Liang Ge, Fotis Sotiropoulos.   

Abstract

We have performed high-resolution fluid-structure interaction simulations of physiologic pulsatile flow through a bi-leaflet mechanical heart valve (BMHV) in an anatomically realistic aorta. The results are compared with numerical simulations of the flow through an identical BMHV implanted in a straight aorta. The comparisons show that although some of the salient features of the flow remain the same, the aorta geometry can have a major effect on both the flow patterns and the motion of the valve leaflets. For the studied configuration, for instance, the BMHV leaflets in the anatomic aorta open much faster and undergo a greater rebound during closing than the same valve in the straight axisymmetric aorta. Even though the characteristic triple-jet structure does emerge downstream of the leaflets for both cases, for the anatomic case the leaflet jets spread laterally and diffuse much faster than in the straight aorta due to the aortic curvature and complex shape of the anatomic sinus. Consequently the leaflet shear layers in the anatomic case remain laminar and organized for a larger portion of the accelerating phase as compared to the shear layers in the straight aorta, which begin to undergo laminar instabilities well before peak systole is reached. For both cases, however, the flow undergoes a very similar explosive transition to the small-scale, turbulent-like state just prior to reaching peak systole. The local maximum shear stress is used as a metric to characterize the mechanical environment experienced by blood cells. Pockets of high local maximum shear are found to be significantly more widespread in the anatomic aorta than in the straight aorta throughout the cardiac cycle. Pockets of high local maximum shear were located near the leaflets and in the aortic arc region. This work clearly demonstrates the importance of the aortic geometry on the flow phenomena in a BMHV and demonstrates the potential of our computational method to carry out image-based patient-specific simulations for clinically relevant studies of heart valve hemodynamics.

Entities:  

Mesh:

Year:  2009        PMID: 19806458      PMCID: PMC3154744          DOI: 10.1007/s10439-009-9807-x

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  30 in total

1.  Turbulence characteristics downstream of bileaflet aortic valve prostheses.

Authors:  J S Liu; P C Lu; S H Chu
Journal:  J Biomech Eng       Date:  2000-04       Impact factor: 2.097

2.  New laboratory technique measures projected dynamic area of prosthetic heart valves.

Authors:  Lawrence N Scotten; David K Walker
Journal:  J Heart Valve Dis       Date:  2004-01

3.  MRI and CFD studies of pulsatile flow in healthy and stenosed carotid bifurcation models.

Authors:  Ian Marshall; Shunzhi Zhao; Panorea Papathanasopoulou; Peter Hoskins; Yun Xu
Journal:  J Biomech       Date:  2004-05       Impact factor: 2.712

4.  Three-dimensional fluid-structure interaction simulation of bileaflet mechanical heart valve flow dynamics.

Authors:  Rui Cheng; Yong G Lai; Krishnan B Chandran
Journal:  Ann Biomed Eng       Date:  2004-11       Impact factor: 3.934

5.  Flow in a mechanical bileaflet heart valve at laminar and near-peak systole flow rates: CFD simulations and experiments.

Authors:  Liang Ge; Hwa-Liang Leo; Fotis Sotiropoulos; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2005-10       Impact factor: 2.097

6.  Single-step stereolithography of complex anatomical models for optical flow measurements.

Authors:  Diane de Zélicourt; Kerem Pekkan; Hiroumi Kitajima; David Frakes; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2005-02       Impact factor: 2.097

7.  Numerical investigation of the hydrodynamics of carangiform swimming in the transitional and inertial flow regimes.

Authors:  Iman Borazjani; Fotis Sotiropoulos
Journal:  J Exp Biol       Date:  2008-05       Impact factor: 3.312

8.  Turbulent stresses downstream of three mechanical aortic valve prostheses in human beings.

Authors:  H Nygaard; P K Paulsen; J M Hasenkam; E M Pedersen; P E Rovsing
Journal:  J Thorac Cardiovasc Surg       Date:  1994-02       Impact factor: 5.209

9.  Laser anemometry measurements of pulsatile flow past aortic valve prostheses.

Authors:  K B Chandran; G N Cabell; B Khalighi; C J Chen
Journal:  J Biomech       Date:  1983       Impact factor: 2.712

10.  Image-based computational simulation of flow dynamics in a giant intracranial aneurysm.

Authors:  David A Steinman; Jaques S Milner; Chris J Norley; Stephen P Lownie; David W Holdsworth
Journal:  AJNR Am J Neuroradiol       Date:  2003-04       Impact factor: 3.825

View more
  23 in total

1.  Measurements of steady flow through a bileaflet mechanical heart valve using stereoscopic PIV.

Authors:  Chris Hutchison; Pierre Sullivan; C Ross Ethier
Journal:  Med Biol Eng Comput       Date:  2010-11-16       Impact factor: 2.602

2.  A non-dimensional parameter for classification of the flow in intracranial aneurysms. I. Simplified geometries.

Authors:  Hafez Asgharzadeh; Iman Borazjani
Journal:  Phys Fluids (1994)       Date:  2019-03-26       Impact factor: 3.521

3.  The effect of implantation orientation of a bileaflet mechanical heart valve on kinematics and hemodynamics in an anatomic aorta.

Authors:  Iman Borazjani; Fotis Sotiropoulos
Journal:  J Biomech Eng       Date:  2010-11       Impact factor: 2.097

4.  Thrombogenic potential of transcatheter aortic valve implantation with trivial paravalvular leakage.

Authors:  Lawrence N Scotten; Rolland Siegel
Journal:  Ann Transl Med       Date:  2014-05

Review 5.  Review of numerical methods for simulation of mechanical heart valves and the potential for blood clotting.

Authors:  Mohamad Shukri Zakaria; Farzad Ismail; Masaaki Tamagawa; Ahmad Fazli Abdul Aziz; Surjatin Wiriadidjaja; Adi Azrif Basri; Kamarul Arifin Ahmad
Journal:  Med Biol Eng Comput       Date:  2017-07-26       Impact factor: 2.602

6.  Fully coupled fluid-structure interaction model of congenital bicuspid aortic valves: effect of asymmetry on hemodynamics.

Authors:  Gil Marom; Hee-Sun Kim; Moshe Rosenfeld; Ehud Raanani; Rami Haj-Ali
Journal:  Med Biol Eng Comput       Date:  2013-03-10       Impact factor: 2.602

7.  A parallel overset-curvilinear-immersed boundary framework for simulating complex 3D incompressible flows.

Authors:  Iman Borazjani; Liang Ge; Trung Le; Fotis Sotiropoulos
Journal:  Comput Fluids       Date:  2013-04-01       Impact factor: 3.013

8.  Possible Early Generation of Physiological Helical Flow Could Benefit the Triflo Trileaflet Heart Valve Prosthesis Compared to Bileaflet Valves.

Authors:  Ch Bruecker; Qianhui Li
Journal:  Bioengineering (Basel)       Date:  2020-12-08

9.  Numerical model of full-cardiac cycle hemodynamics in a total artificial heart and the effect of its size on platelet activation.

Authors:  Gil Marom; Wei-Che Chiu; Jessica R Crosby; Katrina J DeCook; Saurabh Prabhakar; Marc Horner; Marvin J Slepian; Danny Bluestein
Journal:  J Cardiovasc Transl Res       Date:  2014-10-30       Impact factor: 4.132

10.  The role of biofluid mechanics in the assessment of clinical and pathological observations: sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28-30, 2008 Pasadena, California.

Authors:  Maria Siebes; Yiannis Ventikos
Journal:  Ann Biomed Eng       Date:  2010-01-20       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.