Possible Early Generation of Physiological Helical Flow Could Benefit the Triflo Trileaflet Heart Valve Prosthesis Compared to Bileaflet Valves.

Ch Bruecker1, Qianhui Li1.   

Abstract

Background-Physiological helical flow in the ascending aorta has been well documented in the last two decades, accompanied by discussions on possible physiological benefits of such axial swirl. Recent 4D-MRI studies on healthy volunteers have found indications of early generation of helical flow, early in the systole and close to the valve plane. Objectives-Firstly, the aim of the study is to investigate the hypothesis of premature swirl existence in the ventricular outflow tract leading to helical flow in the valve plane, and second to investigate the possible impact of two different mechanical valve designs on the preservation of this early helical flow and its subsequent hemodynamic consequences. Methods-We use a pulse duplicator with an aortic arch and High-Speed Particle Image Velocimetry to document the flow evolution in the systolic cycle. The pulse-duplicator is modified with a swirl-generating insert to generate early helical flow in the valve plane. Special focus is paid to the interaction of such helical flow with different designs of mechanical prosthetic heart valves, comparing a classical bileaflet mechanical heart valve, the St. Jude Medical Regent valve (SJM Regent BMHV), with the Triflo trileaflet mechanical heart valve T2B version (Triflo TMHV). Results-When the swirl-generator is inserted, a vortex is generated in the core flow, demonstrating early helical flow in the valve plane, similar to the observations reported in the recent 4D-MRI study taken for comparison. For the Triflo trileaflet valve, the early helical flow is not obstructed in the central orifice, similar as in the case of the natural valve. Conservation of angular momentum leads to radial expansion of the core flow and flattening of the axial flow profile downstream in the arch. Furthermore, the early helical flow helps to overcome separation at the outer and inner curvature. In contrast, the two parallel leaflets for the bileaflet valve impose a flow straightener effect, annihilating the angular momentum, which has a negative impact on kinetic energy of the flow. Conclusion-The results imply better hemodynamics for the Triflo trileaflet valve based on hydrodynamic arguments under the discussed hypothesis. In addition, it makes the Triflo valve a better candidate for valve replacements in patients with a pathological generation of nonaxial velocity in the ventricle outflow tract.

Entities:  

Keywords:  PIV; aorta; mechanical heart valve prostheses; physiological helical flow; trileaflet

Year:  2020        PMID: 33302564      PMCID: PMC7763138          DOI: 10.3390/bioengineering7040158

Source DB:  PubMed          Journal:  Bioengineering (Basel)        ISSN: 2306-5354


  26 in total

1.  MRI measurement of time-resolved wall shear stress vectors in a carotid bifurcation model, and comparison with CFD predictions.

Authors:  Panorea Papathanasopoulou; Shunzhi Zhao; Uwe Köhler; Malcolm B Robertson; Quan Long; Peter Hoskins; X Yun Xu; Ian Marshall
Journal:  J Magn Reson Imaging       Date:  2003-02       Impact factor: 4.813

2.  Mitral mechanical heart valves: in vitro studies of their closure, vortex and microbubble formation with possible medical implications.

Authors:  Simcha Milo; Edmond Rambod; Chaim Gutfinger; Morteza Gharib
Journal:  Eur J Cardiothorac Surg       Date:  2003-09       Impact factor: 4.191

3.  The role of optimal vortex formation in biological fluid transport.

Authors:  John O Dabiri; Morteza Gharib
Journal:  Proc Biol Sci       Date:  2005-08-07       Impact factor: 5.349

4.  The influence of the aortic root geometry on flow characteristics of a prosthetic heart valve.

Authors:  Oleksandr Barannyk; Peter Oshkai
Journal:  J Biomech Eng       Date:  2015-03-05       Impact factor: 2.097

5.  Reproducibility of flow and wall shear stress analysis using flow-sensitive four-dimensional MRI.

Authors:  Michael Markl; Wolf Wallis; Andreas Harloff
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

6.  The Atheroprotective Nature of Helical Flow in Coronary Arteries.

Authors:  Giuseppe De Nisco; Annette M Kok; Claudio Chiastra; Diego Gallo; Ayla Hoogendoorn; Francesco Migliavacca; Jolanda J Wentzel; Umberto Morbiducci
Journal:  Ann Biomed Eng       Date:  2018-11-28       Impact factor: 3.934

Review 7.  Aortic dilatation in patients with bicuspid aortic valve.

Authors:  Subodh Verma; Samuel C Siu
Journal:  N Engl J Med       Date:  2014-05-15       Impact factor: 91.245

8.  How to Decide Between a Bioprosthetic and Mechanical Valve.

Authors:  Tirone David
Journal:  Can J Cardiol       Date:  2020-09-28       Impact factor: 5.223

9.  High-resolution fluid-structure interaction simulations of flow through a bi-leaflet mechanical heart valve in an anatomic aorta.

Authors:  Iman Borazjani; Liang Ge; Fotis Sotiropoulos
Journal:  Ann Biomed Eng       Date:  2009-10-06       Impact factor: 3.934

10.  Quantitative Analysis of Vortical Blood Flow in the Thoracic Aorta Using 4D Phase Contrast MRI.

Authors:  Jochen von Spiczak; Gerard Crelier; Daniel Giese; Sebastian Kozerke; David Maintz; Alexander Christian Bunck
Journal:  PLoS One       Date:  2015-09-29       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.