Literature DB >> 19802672

Analysis of early failure of the locking compression plate in osteoporotic proximal humerus fractures.

Ivan D Micic1, Kyung-Chun Kim, Dong-Ju Shin, Sang-Jin Shin, Poong-Taek Kim, Il-Hyung Park, In-Ho Jeon.   

Abstract

BACKGROUND: Although there has been continuous evolution in the management of fracture fixation, treatment for osteoporotic proximal humerus fractures is still challenging to trauma surgeons. The purpose of this study was to report early failure of the locking compression plate (LCP) in the treatment of osteoporotic proximal humerus fracture and characterize the mode of failure.
METHODS: Nine patients, older than 65 years, underwent internal fixation with the use of a locking compression plate and had early failure within 4 weeks postoperatively. According to Neer's classification, five were included in a two-part surgical neck fracture, three in a three-part fracture, and one in a four-part fracture.
RESULTS: All failures occurred with back-out of the plate-screw construct, leading to varus displacement in eight patients and plate breakage in one. Revision surgery was performed in six patients using replating and tension band wiring with a bone graft, and three patients underwent hemiarthroplasty. The average UCLA score was 25 points for the hemiarthroplasty group and 30 points for the reconstruction group.
CONCLUSIONS: Early postoperative failure of the LCP developed within 4 weeks with a presentation of en bloc back-out of the plate-screw construct and plate breakage. Possible risk factors included malreduction, loss of medial support, and negligence of tension band sutures on the tuberosities.

Entities:  

Mesh:

Year:  2009        PMID: 19802672     DOI: 10.1007/s00776-009-1382-3

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  15 in total

1.  Short-term and long-term orthopaedic issues in patients with fragility fractures.

Authors:  Susan V Bukata; Stephen L Kates; Regis J O'Keefe
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

2.  The calcar screw in angular stable plate fixation of proximal humeral fractures--a case study.

Authors:  Georg Osterhoff; Christian Ossendorf; Guido A Wanner; Hans-Peter Simmen; Clément M Werner
Journal:  J Orthop Surg Res       Date:  2011-09-24       Impact factor: 2.359

3.  Similar outcomes for nail versus plate fixation of three-part proximal humeral fractures.

Authors:  Gerhard Konrad; Laurent Audigé; Simon Lambert; Ralph Hertel; Norbert P Südkamp
Journal:  Clin Orthop Relat Res       Date:  2011-08-31       Impact factor: 4.176

4.  The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized study.

Authors:  Lei Zhang; Jinyou Zheng; Weiliang Wang; Guangmao Lin; Yijiang Huang; Jin Zheng; Ghamor-Amegavi Edem Prince; Guojing Yang
Journal:  Int Orthop       Date:  2011-03-10       Impact factor: 3.075

5.  Evidence for success with locking plates for fragility fractures.

Authors:  Charles N Cornell; Omri Ayalon
Journal:  HSS J       Date:  2011-02-01

6.  Outcome Analysis of Locking Plate Fixation in Proximal Humerus Fracture.

Authors:  Mayank Vijayvargiya; Abhishek Pathak; Sanjiv Gaur
Journal:  J Clin Diagn Res       Date:  2016-08-01

Review 7.  Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus.

Authors:  Stig Brorson; Lars H Frich; Annika Winther; Asbjørn Hróbjartsson
Journal:  Acta Orthop       Date:  2011-06-10       Impact factor: 3.717

8.  Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support.

Authors:  Yu He; Yaoshen Zhang; Yan Wang; Dongsheng Zhou; Fu Wang
Journal:  J Orthop Surg Res       Date:  2017-05-12       Impact factor: 2.359

9.  The mechanical benefit of medial support screws in locking plating of proximal humerus fractures.

Authors:  Wen Zhang; Langqing Zeng; Yanjie Liu; Yao Pan; Wei Zhang; Changqing Zhang; Bingfang Zeng; Yunfeng Chen
Journal:  PLoS One       Date:  2014-08-01       Impact factor: 3.240

10.  Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis.

Authors:  Ali Jabran; Chris Peach; Zhenmin Zou; Lei Ren
Journal:  Biomed Eng Online       Date:  2018-01-25       Impact factor: 2.819