Literature DB >> 19801477

Development of a test system to evaluate procedures for decontamination of respirators containing viral droplets.

Evanly Vo1, Samy Rengasamy, Ronald Shaffer.   

Abstract

The aim of this study was to develop a test system to evaluate the effectiveness of procedures for decontamination of respirators contaminated with viral droplets. MS2 coliphage was used as a surrogate for pathogenic viruses. A viral droplet test system was constructed, and the size distribution of viral droplets loaded directly onto respirators was characterized using an aerodynamic particle sizer. The sizes ranged from 0.5 to 15 mum, and the sizes of the majority of the droplets were the range from 0.74 to 3.5 mum. The results also showed that the droplet test system generated similar droplet concentrations (particle counts) at different respirator locations. The test system was validated by studying the relative efficiencies of decontamination of sodium hypochlorite (bleach) and UV irradiation with droplets containing MS2 virus on filtering facepiece respirators. It was hypothesized that more potent decontamination treatments would result in corresponding larger decreases in the number of viable viruses recovered from the respirators. Sodium hypochlorite doses of 2.75 to 5.50 mg/liter with a 10-min decontamination period resulted in approximately 3- to 4-log reductions in the level of MS2 coliphage. When higher sodium hypochlorite doses (> or =8.25 mg/liter) were used with the same contact time that was used for the dilute solutions containing 2.75 to 5.50 mg/liter, all MS2 was inactivated. For UV decontamination at a wavelength of 254 nm, an approximately 3-log reduction in the level of MS2 virus was achieved with dose of 4.32 J/cm(2) (3 h of contact time with a UV intensity of 0.4 mW/cm(2)), while with higher doses of UV irradiation (> or =7.20 J/cm(2); UV intensity, 0.4 mW/cm(2); contact times, > or =5 h), all MS2 was inactivated. These findings may lead to development of a standard method to test decontamination of respirators challenged by viral droplets.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19801477      PMCID: PMC2786399          DOI: 10.1128/AEM.00799-09

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  19 in total

1.  The size and the duration of air-carriage of respiratory droplets and droplet-nuclei.

Authors:  J P Duguid
Journal:  J Hyg (Lond)       Date:  1946-09

2.  Carrier tests to assess microbicidal activities of chemical disinfectants for use on medical devices and environmental surfaces.

Authors:  V Susan Springthorpe; Syed A Sattar
Journal:  J AOAC Int       Date:  2005 Jan-Feb       Impact factor: 1.913

3.  Sampling methodologies and dosage assessment techniques for submicrometre and ultrafine virus aerosol particles.

Authors:  C J Hogan; E M Kettleson; M-H Lee; B Ramaswami; L T Angenent; P Biswas
Journal:  J Appl Microbiol       Date:  2005       Impact factor: 3.772

4.  The use of bacteriophage MS2 as a model system to evaluate virucidal hand disinfectants.

Authors:  M V Jones; K Bellamy; R Alcock; R Hudson
Journal:  J Hosp Infect       Date:  1991-04       Impact factor: 3.926

5.  Development of a test system to apply virus-containing particles to filtering facepiece respirators for the evaluation of decontamination procedures.

Authors:  Edward Fisher; Samy Rengasamy; Dennis Viscusi; Evanly Vo; Ronald Shaffer
Journal:  Appl Environ Microbiol       Date:  2009-01-09       Impact factor: 4.792

6.  Effect of testing method on apparent activities of antiviral disinfectants and antiseptics.

Authors:  J D Woolwine; J L Gerberding
Journal:  Antimicrob Agents Chemother       Date:  1995-04       Impact factor: 5.191

7.  Assessment of experimental and natural viral aerosols.

Authors:  P J Gerone; R B Couch; G V Keefer; R G Douglas; E B Derrenbacher; V Knight
Journal:  Bacteriol Rev       Date:  1966-09

8.  The refined structure of bacteriophage MS2 at 2.8 A resolution.

Authors:  R Golmohammadi; K Valegård; K Fridborg; L Liljas
Journal:  J Mol Biol       Date:  1993-12-05       Impact factor: 5.469

Review 9.  Transmission of infectious diseases during commercial air travel.

Authors:  Alexandra Mangili; Mark A Gendreau
Journal:  Lancet       Date:  2005 Mar 12-18       Impact factor: 79.321

10.  Possible SARS coronavirus transmission during cardiopulmonary resuscitation.

Authors:  Michael D Christian; Mona Loutfy; L Clifford McDonald; Kennth F Martinez; Mariana Ofner; Tom Wong; Tamara Wallington; Wayne L Gold; Barbara Mederski; Karen Green; Donald E Low
Journal:  Emerg Infect Dis       Date:  2004-02       Impact factor: 6.883

View more
  26 in total

1.  Effects of relative humidity and spraying medium on UV decontamination of filters loaded with viral aerosols.

Authors:  Myung-Heui Woo; Adam Grippin; Diandra Anwar; Tamara Smith; Chang-Yu Wu; Joseph D Wander
Journal:  Appl Environ Microbiol       Date:  2012-06-08       Impact factor: 4.792

Review 2.  Current Understanding of Ultraviolet-C Decontamination of N95 Filtering Facepiece Respirators.

Authors:  Samantha M Grist; Alisha Geldert; Anjali Gopal; Alison Su; Halleh B Balch; Amy E Herr
Journal:  Appl Biosaf       Date:  2021-06-02

3.  Validation and application of models to predict facemask influenza contamination in healthcare settings.

Authors:  Edward M Fisher; John D Noti; William G Lindsley; Francoise M Blachere; Ronald E Shaffer
Journal:  Risk Anal       Date:  2014-03-04       Impact factor: 4.000

4.  MS2 Coliphage as a Surrogate for 2009 Pandemic Influenza A (H1N1) Virus (pH1N1) in Surface Survival Studies on N95 Filtering Facepiece Respirators.

Authors:  A D Coulliette; K A Perry; E M Fisher; J R Edwards; R E Shaffer; J Noble-Wang
Journal:  J Int Soc Respir Prot       Date:  2014-01

5.  LUCIA: An open source device for disinfection of N95 masks using UV-C radiation.

Authors:  Marcel Bentancor; Sebastián Fernández; Federico Viera; Sarita Etcheverry; Carolina Poradosú; Pablo D'Angelo; Hernán Montemuiño; Santiago Mirazo; Álvaro Irigoyen; Analía Sanabria; Horacio Failache
Journal:  HardwareX       Date:  2021-02-26

6.  Evaluation of microwave steam bags for the decontamination of filtering facepiece respirators.

Authors:  Edward M Fisher; Jessica L Williams; Ronald E Shaffer
Journal:  PLoS One       Date:  2011-04-15       Impact factor: 3.240

7.  New technique to evaluate decontamination methods for filtering facepiece respirators.

Authors:  Evanly Vo; Samy Rengasamy; Susan Xu; Matthew Horvatin; Ziqing Zhuang
Journal:  Am J Infect Control       Date:  2021-01-29       Impact factor: 4.303

8.  Effects of Ultraviolet Germicidal Irradiation (UVGI) on N95 Respirator Filtration Performance and Structural Integrity.

Authors:  William G Lindsley; Stephen B Martin; Robert E Thewlis; Khachatur Sarkisian; Julian O Nwoko; Kenneth R Mead; John D Noti
Journal:  J Occup Environ Hyg       Date:  2015       Impact factor: 2.155

Review 9.  Efficacy and safety of decontamination for N95 respirator reuse: a systematic literature search and narrative synthesis.

Authors:  Benjamin E Steinberg; Kazuyoshi Aoyama; Mark McVey; David Levin; Asad Siddiqui; Farrukh Munshey; Neil M Goldenberg; David Faraoni; Jason T Maynes
Journal:  Can J Anaesth       Date:  2020-07-27       Impact factor: 6.713

10.  Preparing for an Influenza Pandemic: Hospital Acceptance Study of Filtering Facepiece Respirator Decontamination Using Ultraviolet Germicidal Irradiation.

Authors:  Christopher Nemeth; Dawn Laufersweiler; Emily Polander; Christianna Orvis; Del Harnish; Sherwin E Morgan; Michael O'Connor; Saul Hymes; Sharon Nachman; Brian Heimbuch
Journal:  J Patient Saf       Date:  2020-06       Impact factor: 2.243

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.