Literature DB >> 15759741

Carrier tests to assess microbicidal activities of chemical disinfectants for use on medical devices and environmental surfaces.

V Susan Springthorpe1, Syed A Sattar.   

Abstract

For well over a decade, many deficiencies have been identified in current AOAC methods used to assess the microbicidal activities of chemical disinfectants on medical devices and environmental surfaces. This report discusses the development of quantitative carrier tests (QCT) designed to address these concerns. Decontamination of surfaces with dried inocula is invariably more difficult than when microorganisms are in suspension. For medical device as well as environmental decontamination, microbicides are used on contaminated surfaces, thus making it necessary to evaluate their microbicidal action on representative carrier materials contaminated with a dried challenge microorganism(s). Our approach is a 2-tiered QCT. The first tier (QCT-1) uses relatively ideal conditions to assess performance of the microbicide for screening purposes; the test uses smooth glass surfaces and quantities of disinfectant in excess of those likely to be experienced in the field. The second tier of testing (QCT-2) is more stringent because it uses (1) disks of brushed stainless steel as carriers, (2) only 50 microL of the test formulation on each carrier as compared to 1 mL in QCT-1, and (3) an added soil load to simulate the presence of residual body fluids or accumulated surface dirt. This review also discusses the factors that affect disinfection of medical devices and environmental surfaces in the context of the methodology used to evaluate the potency of microbicides. Specific recommendations for discussion are included, and performance criteria are suggested based on a risk-reduction approach for different classes of disinfectants. The focus is on improving the relevance of the test methodology to actual field use of disinfectants for devices and facilities in health care, and potentially in other settings. It is hoped that this review and its recommendations will initiate needed discussion and resolution of the many issues identified.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15759741

Source DB:  PubMed          Journal:  J AOAC Int        ISSN: 1060-3271            Impact factor:   1.913


  17 in total

1.  Use of a mixture of surrogates for infectious bioagents in a standard approach to assessing disinfection of environmental surfaces.

Authors:  Safaa Sabbah; Susan Springthorpe; Syed A Sattar
Journal:  Appl Environ Microbiol       Date:  2010-07-16       Impact factor: 4.792

2.  Development of a test system to apply virus-containing particles to filtering facepiece respirators for the evaluation of decontamination procedures.

Authors:  Edward Fisher; Samy Rengasamy; Dennis Viscusi; Evanly Vo; Ronald Shaffer
Journal:  Appl Environ Microbiol       Date:  2009-01-09       Impact factor: 4.792

3.  Enhanced inactivation of avian influenza virus at -20°C by disinfectants supplemented with calcium chloride or other antifreeze agents.

Authors:  Jiewen Guan; Maria Chan; Brian W Brooks; Elizabeth Rohonczy
Journal:  Can J Vet Res       Date:  2015-10       Impact factor: 1.310

4.  Reducing the health impact of infectious agents: the significance of preventive strategies.

Authors:  Syed A Sattar
Journal:  GMS Krankenhhyg Interdiszip       Date:  2007-09-13

5.  Quantitative method to determine sporicidal decontamination of building surfaces by gaseous fumigants, and issues related to laboratory-scale studies.

Authors:  Vipin K Rastogi; Lalena Wallace; Lisa S Smith; Shawn P Ryan; Blair Martin
Journal:  Appl Environ Microbiol       Date:  2009-04-03       Impact factor: 4.792

6.  Comprehensive comparison of cultivable norovirus surrogates in response to different inactivation and disinfection treatments.

Authors:  Theresa Cromeans; Geun Woo Park; Veronica Costantini; David Lee; Qiuhong Wang; Tibor Farkas; Alvin Lee; Jan Vinjé
Journal:  Appl Environ Microbiol       Date:  2014-07-11       Impact factor: 4.792

7.  Influence of temperature and organic load on chemical disinfection of Geobacillus steareothermophilus spores, a surrogate for Bacillus anthracis.

Authors:  Jiewen Guan; Maria Chan; Brian W Brooks; Liz Rohonczy
Journal:  Can J Vet Res       Date:  2013-04       Impact factor: 1.310

8.  Development of a test system to evaluate procedures for decontamination of respirators containing viral droplets.

Authors:  Evanly Vo; Samy Rengasamy; Ronald Shaffer
Journal:  Appl Environ Microbiol       Date:  2009-10-02       Impact factor: 4.792

9.  Identification by quantitative carrier test of surrogate spore-forming bacteria to assess sporicidal chemicals for use against Bacillus anthracis.

Authors:  Miles R Majcher; Kathryn A Bernard; Syed A Sattar
Journal:  Appl Environ Microbiol       Date:  2007-12-14       Impact factor: 4.792

10.  Inactivation of murine norovirus by chemical biocides on stainless steel.

Authors:  Thomas Magulski; Dajana Paulmann; Birte Bischoff; Britta Becker; Eike Steinmann; Jörg Steinmann; Peter Goroncy-Bermes; Jochen Steinmann
Journal:  BMC Infect Dis       Date:  2009-07-07       Impact factor: 3.090

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.