Literature DB >> 19800956

PLGA/PVA hydrogel composites for long-term inflammation control following s.c. implantation.

Upkar Bhardwaj1, Radhakrishana Sura, Fotios Papadimitrakopoulos, Diane J Burgess.   

Abstract

Dexamethasone loaded PLGA microsphere/PVA hydrogel composites were investigated as an outer drug-eluting coating for implantable devices to provide protection against the foreign body response. Two populations of microspheres were prepared: 25 kDa PLGA microspheres which had a typical triphasic release profile extending over 30-33 days; and 75 kDa PLGA microspheres which showed minimal release for the first 25 days and then increased to release over 80-85 days. Incorporation of the microspheres in the composites only slightly altered the release profile. Composites containing 25 kDa microspheres released dexamethasone over 30-35 days while composites containing combinations of 25 and 75 kDa microspheres in equal amounts released over 90-95 days. Pharmacodynamic studies showed that composites containing only 25 kDa microspheres provided protection against the inflammatory response for 1 month, however, a delayed tissue reaction developed after exhaustion of dexamethasone. This demonstrated that sustained release of the anti-inflammatory agent is required over the entire implant lifetime to control inflammation and prevent fibrosis. Composites fabricated using combinations of 25 kDa and 75 kDa microspheres controlled the tissue reaction for 90 days. This strategy of combining different microsphere populations in the same composite coating can be used to tune the release profiles for the desired extent and duration of release. Such composites offer an innovative solution to control the foreign body response at the tissue-device interface.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19800956     DOI: 10.1016/j.ijpharm.2009.09.046

Source DB:  PubMed          Journal:  Int J Pharm        ISSN: 0378-5173            Impact factor:   5.875


  22 in total

1.  Microspheres prepared with PLGA blends for delivery of dexamethasone for implantable medical devices.

Authors:  Yan Wang; Bing Gu; Diane J Burgess
Journal:  Pharm Res       Date:  2013-08-15       Impact factor: 4.200

2.  Minimally invasive, longitudinal monitoring of biomaterial-associated inflammation by fluorescence imaging.

Authors:  Shivaram Selvam; Kousik Kundu; Kellie L Templeman; Niren Murthy; Andrés J García
Journal:  Biomaterials       Date:  2011-08-02       Impact factor: 12.479

3.  Accelerated in vitro release testing of implantable PLGA microsphere/PVA hydrogel composite coatings.

Authors:  Jie Shen; Diane J Burgess
Journal:  Int J Pharm       Date:  2011-10-13       Impact factor: 5.875

Review 4.  Biomaterials/tissue interactions: possible solutions to overcome foreign body response.

Authors:  Jacqueline M Morais; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  AAPS J       Date:  2010-02-09       Impact factor: 4.009

Review 5.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

6.  A miniaturized transcutaneous system for continuous glucose monitoring.

Authors:  Robert A Croce; SanthiSagar Vaddiraju; Jun Kondo; Yan Wang; Liang Zuo; Kai Zhu; Syed K Islam; Diane J Burgess; Fotios Papadimitrakopoulos; Faquir C Jain
Journal:  Biomed Microdevices       Date:  2013-02       Impact factor: 2.838

7.  Effect of dexamethasone-loaded poly(lactic-co-glycolic acid) microsphere/poly(vinyl alcohol) hydrogel composite coatings on the basic characteristics of implantable glucose sensors.

Authors:  Yan Wang; Santhisagar Vaddiraju; Liangliang Qiang; Xiaoming Xu; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

8.  PLGA microsphere/PVA hydrogel coatings suppress the foreign body reaction for 6 months.

Authors:  Bing Gu; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Control Release       Date:  2018-09-24       Impact factor: 9.776

9.  Microsphere erosion in outer hydrogel membranes creating macroscopic porosity to counter biofouling-induced sensor degradation.

Authors:  S Vaddiraju; Y Wang; L Qiang; D J Burgess; F Papadimitrakopoulos
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

10.  Prediction of dexamethasone release from PLGA microspheres prepared with polymer blends using a design of experiment approach.

Authors:  Bing Gu; Diane J Burgess
Journal:  Int J Pharm       Date:  2015-09-15       Impact factor: 5.875

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.