Literature DB >> 19800013

Cortical layer-dependent arterial blood volume changes: improved spatial specificity relative to BOLD fMRI.

Tae Kim1, Seong-Gi Kim.   

Abstract

The spatial specificity of functional hemodynamic responses was examined by simultaneous mapping of BOLD changes and quantitative changes in cerebral arterial blood volume (DeltaCBV(a)) across the cortical depth in cats (n=7) during 40-s visual stimulation. Studies were performed at 9.4 T using the recently developed, non-invasive magnetization transfer (MT)-varied gradient-echo (GE) fMRI technique to separate signals from MT-independent arterial blood and MT-dependent tissue. The highest conventional BOLD signal changes occurred at the cortical surface, where large pial veins exist, whereas the highest CBV(a) changes occurred in the middle of the cortex, where T(1)-weighted images show a hyperintense layer. In the middle cortical region, the average BOLD change (echo time=20 ms) was 1.16+/-0.45% during stimulation and -0.59+/-0.31% during the post-stimulus period, while the average DeltaCBV(a) was 0.33+/-0.02 ml/100 g during stimulation and -0.08+/-0.12 ml/100 g post-stimulus (post-stimulus DeltaCBV(a) is not statistically significant). Time-dependencies of the DeltaCBV(a) cortical profiles are similar to total CBV responses previously measured during visual stimulation in cats with a susceptibility contrast agent indicating, that blood volume changes mostly originate from arterial vessels. Our findings demonstrate the value of non-invasive and quantitative DeltaCBV(a) measurement in high-resolution MT-varied GE fMRI studies, where spatial specificity is better localized to sites of neural activity as compared with conventional GE BOLD changes.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19800013      PMCID: PMC2819732          DOI: 10.1016/j.neuroimage.2009.09.061

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  30 in total

1.  Magnetization transfer contrast: method for improving contrast in gradient-recalled-echo images.

Authors:  S D Wolff; J Eng; R S Balaban
Journal:  Radiology       Date:  1991-04       Impact factor: 11.105

2.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation.

Authors:  S Ogawa; T M Lee; A R Kay; D W Tank
Journal:  Proc Natl Acad Sci U S A       Date:  1990-12       Impact factor: 11.205

3.  Laminar profiles of functional activity in the human brain.

Authors:  David Ress; Gary H Glover; Junjie Liu; Brian Wandell
Journal:  Neuroimage       Date:  2006-09-29       Impact factor: 6.556

4.  Theoretical and experimental investigation of the VASO contrast mechanism.

Authors:  Manus J Donahue; Hanzhang Lu; Craig K Jones; Richard A E Edden; James J Pekar; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

5.  Functional MRI impulse response for BOLD and CBV contrast in rat somatosensory cortex.

Authors:  Afonso C Silva; Alan P Koretsky; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

6.  Improved cortical-layer specificity of vascular space occupancy fMRI with slab inversion relative to spin-echo BOLD at 9.4 T.

Authors:  Tao Jin; Seong-Gi Kim
Journal:  Neuroimage       Date:  2007-12-08       Impact factor: 6.556

7.  Cortical depth dependence and implications on the neuronal specificity of the functional apparent diffusion coefficient contrast.

Authors:  Trong-Kha Truong; Allen W Song
Journal:  Neuroimage       Date:  2009-04-18       Impact factor: 6.556

8.  Cortical layer-dependent dynamic blood oxygenation, cerebral blood flow and cerebral blood volume responses during visual stimulation.

Authors:  Tao Jin; Seong-Gi Kim
Journal:  Neuroimage       Date:  2008-07-04       Impact factor: 6.556

9.  Functional MRI with magnetization transfer effects: determination of BOLD and arterial blood volume changes.

Authors:  Tae Kim; Kristy Hendrich; Seong-Gi Kim
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

10.  Noninvasive measurement of arterial cerebral blood volume using Look-Locker EPI and arterial spin labeling.

Authors:  M J Brookes; P G Morris; P A Gowland; S T Francis
Journal:  Magn Reson Med       Date:  2007-07       Impact factor: 3.737

View more
  32 in total

1.  Contributions of dynamic venous blood volume versus oxygenation level changes to BOLD fMRI.

Authors:  Xiaopeng Zong; Tae Kim; Seong-Gi Kim
Journal:  Neuroimage       Date:  2012-02-28       Impact factor: 6.556

2.  Similarities and differences in arterial responses to hypercapnia and visual stimulation.

Authors:  Yi-Ching Lynn Ho; Esben Thade Petersen; Ivan Zimine; Xavier Golay
Journal:  J Cereb Blood Flow Metab       Date:  2010-08-11       Impact factor: 6.200

3.  Temporal dynamics and spatial specificity of arterial and venous blood volume changes during visual stimulation: implication for BOLD quantification.

Authors:  Tae Kim; Seong-Gi Kim
Journal:  J Cereb Blood Flow Metab       Date:  2010-12-22       Impact factor: 6.200

Review 4.  The future of ultra-high field MRI and fMRI for study of the human brain.

Authors:  Jeff H Duyn
Journal:  Neuroimage       Date:  2011-10-28       Impact factor: 6.556

Review 5.  Laminar fMRI: What can the time domain tell us?

Authors:  Natalia Petridou; Jeroen C W Siero
Journal:  Neuroimage       Date:  2017-07-20       Impact factor: 6.556

Review 6.  Foundations of layer-specific fMRI and investigations of neurophysiological activity in the laminarized neocortex and olfactory bulb of animal models.

Authors:  Alexander John Poplawsky; Mitsuhiro Fukuda; Seong-Gi Kim
Journal:  Neuroimage       Date:  2017-05-12       Impact factor: 6.556

7.  Regulation of blood flow in the retinal trilaminar vascular network.

Authors:  Tess E Kornfield; Eric A Newman
Journal:  J Neurosci       Date:  2014-08-20       Impact factor: 6.167

Review 8.  The BOLD post-stimulus undershoot, one of the most debated issues in fMRI.

Authors:  Peter C M van Zijl; Jun Hua; Hanzhang Lu
Journal:  Neuroimage       Date:  2012-01-09       Impact factor: 6.556

9.  Spatiotemporal characteristics and vascular sources of neural-specific and -nonspecific fMRI signals at submillimeter columnar resolution.

Authors:  Chan Hong Moon; Mitsuhiro Fukuda; Seong-Gi Kim
Journal:  Neuroimage       Date:  2012-08-30       Impact factor: 6.556

Review 10.  Noninvasive functional imaging of cerebral blood volume with vascular-space-occupancy (VASO) MRI.

Authors:  Hanzhang Lu; Jun Hua; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2013-01-28       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.