Literature DB >> 19794232

A subspace decomposition approach toward recognizing valid pulsatile signals.

Shadnaz Asgari1, Peng Xu, Marvin Bergsneider, Xiao Hu.   

Abstract

Following recent studies, the automatic analysis of intracranial pressure (ICP) pulses appears to be a promising tool for the prediction of critical intracranial and cerebrovascular pathophysiological variations during the management of many neurological disorders. A pulse analysis framework has been recently developed to automatically extract morphological features of ICP pulses. The algorithm is capable of enhancing the quality of ICP signals, recognizing valid (not contaminated with noise or artifacts) ICP pulses and designating the locations of the three ICP sub-peaks in a pulse. This paper extends the algorithm by proposing a singular value decomposition (SVD) technique to replace the correlation-based approach originally utilized in recognizing valid ICP pulses. The validation of the proposed method is conducted on a large database of ICP signals built from 700 h of recordings from 67 neurosurgical patients. A comparative analysis of the valid ICP recognition using the proposed SVD technique and the correlation-based method demonstrates a significant improvement in terms of (1) accuracy (61.96% reduction in the false positive rate while keeping the true positive rate as high as 99.08%) and (2) computational time (91.14% less time consumption), all in favor of the proposed method. Finally, this SVD-based valid pulse recognition can be potentially applied to process pulsatile signals other than ICP because no proprietary ICP features are incorporated in the algorithm.

Entities:  

Mesh:

Year:  2009        PMID: 19794232      PMCID: PMC2851740          DOI: 10.1088/0967-3334/30/11/006

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  31 in total

1.  A transform domain SVD filter for suppression of muscle noise artefacts in exercise ECG's.

Authors:  J S Paul; M R Reddy; V J Kumar
Journal:  IEEE Trans Biomed Eng       Date:  2000-05       Impact factor: 4.538

2.  A novel algorithm for cardiac biosignal filtering based on filtered residue method.

Authors:  Shahriar Iravanian; Leslie Tung
Journal:  IEEE Trans Biomed Eng       Date:  2002-11       Impact factor: 4.538

3.  Projective filtering of time-aligned ECG beats.

Authors:  Marian Kotas
Journal:  IEEE Trans Biomed Eng       Date:  2004-07       Impact factor: 4.538

4.  Use of long-term intracranial pressure measurement to assess hydrocephalic patients prior to shunt surgery.

Authors:  L Symon; N W Dorsch
Journal:  J Neurosurg       Date:  1975-03       Impact factor: 5.115

5.  A robust approach toward recognizing valid arterial-blood-pressure pulses.

Authors:  Shadnaz Asgari; Marvin Bergsneider; Xiao Hu
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-10-30

6.  Changes in the cerebrospinal fluid pulse wave spectrum associated with raised intracranial pressure.

Authors:  H Takizawa; T Gabra-Sanders; J D Miller
Journal:  Neurosurgery       Date:  1987-03       Impact factor: 4.654

7.  Systems analysis of intracranial pressure. Comparison with volume-pressure test and CSF-pulse amplitude analysis.

Authors:  M Chopp; H D Portnoy
Journal:  J Neurosurg       Date:  1980-10       Impact factor: 5.115

8.  Analysis of the cerebrospinal fluid pulse wave in intracranial pressure.

Authors:  E R Cardoso; J O Rowan; S Galbraith
Journal:  J Neurosurg       Date:  1983-11       Impact factor: 5.115

9.  Cerebrospinal fluid pulse wave form analysis during hypercapnia and hypoxia.

Authors:  H D Portnoy; M Chopp
Journal:  Neurosurgery       Date:  1981-07       Impact factor: 4.654

10.  Nonvolumetric methods of detecting impaired intracranial compliance or reactivity: pulse width and wave form analysis.

Authors:  H A Wilkinson; N Schuman; J Ruggiero
Journal:  J Neurosurg       Date:  1979-06       Impact factor: 5.115

View more
  10 in total

1.  Intracranial hypertension prediction using extremely randomized decision trees.

Authors:  Fabien Scalzo; Robert Hamilton; Shadnaz Asgari; Sunghan Kim; Xiao Hu
Journal:  Med Eng Phys       Date:  2012-03-07       Impact factor: 2.242

2.  A comparison of vital signs charted by nurses with automated acquired values using waveform quality indices.

Authors:  Monica Sapo; Shaozhi Wu; Shadnaz Asgari; Norma McNair; Farzad Buxey; Neil Martin; Xiao Hu
Journal:  J Clin Monit Comput       Date:  2009-07-23       Impact factor: 2.502

3.  Intracranial pressure pulse morphological features improved detection of decreased cerebral blood flow.

Authors:  Xiao Hu; Thomas Glenn; Fabien Scalzo; Marvin Bergsneider; Chris Sarkiss; Neil Martin; Paul Vespa
Journal:  Physiol Meas       Date:  2010-03-26       Impact factor: 2.833

4.  A robust approach toward recognizing valid arterial-blood-pressure pulses.

Authors:  Shadnaz Asgari; Marvin Bergsneider; Xiao Hu
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-10-30

5.  Consistent changes in intracranial pressure waveform morphology induced by acute hypercapnic cerebral vasodilatation.

Authors:  Shadnaz Asgari; Marvin Bergsneider; Robert Hamilton; Paul Vespa; Xiao Hu
Journal:  Neurocrit Care       Date:  2011-08       Impact factor: 3.210

6.  Generalizability of SuperAlarm via Cross-Institutional Performance Evaluation.

Authors:  Ran Xiao; Duc Do; Cheng Ding; Karl Meisel; Randall Lee; Xiao Hu
Journal:  IEEE Access       Date:  2020-07-16       Impact factor: 3.367

7.  Inter-subject correlation exists between morphological metrics of cerebral blood flow velocity and intracranial pressure pulses.

Authors:  Sunghan Kim; Xiao Hu; David McArthur; Robert Hamilton; Marvin Bergsneider; Thomas Glenn; Neil Martin; Paul Vespa
Journal:  Neurocrit Care       Date:  2010-12-07       Impact factor: 3.210

8.  Lack of consistent intracranial pressure pulse morphological changes during episodes of microdialysis lactate/pyruvate ratio increase.

Authors:  Shadnaz Asgari; Paul Vespa; Marvin Bergsneider; Xiao Hu
Journal:  Physiol Meas       Date:  2011-09-09       Impact factor: 2.833

Review 9.  Automated Detection and Screening of Traumatic Brain Injury (TBI) Using Computed Tomography Images: A Comprehensive Review and Future Perspectives.

Authors:  Vidhya V; Anjan Gudigar; U Raghavendra; Ajay Hegde; Girish R Menon; Filippo Molinari; Edward J Ciaccio; U Rajendra Acharya
Journal:  Int J Environ Res Public Health       Date:  2021-06-16       Impact factor: 3.390

10.  Continuous detection of cerebral vasodilatation and vasoconstriction using intracranial pulse morphological template matching.

Authors:  Shadnaz Asgari; Nestor Gonzalez; Andrew W Subudhi; Robert Hamilton; Paul Vespa; Marvin Bergsneider; Robert C Roach; Xiao Hu
Journal:  PLoS One       Date:  2012-11-30       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.