Literature DB >> 10851809

A transform domain SVD filter for suppression of muscle noise artefacts in exercise ECG's.

J S Paul1, M R Reddy, V J Kumar.   

Abstract

The proposed filter assumes the noisy electrocardiography (ECG) to be modeled as a signal of deterministic nature, corrupted by additive muscle noise artefact. The muscle noise component is treated to be stationary with known second-order characteristics. Since noise-free ECG is shown to possess a narrow-band structure in discrete cosine transform (DCT) domain and the second-order statistical properties of the additive noise component is preserved due to the orthogonality property of DCT, noise abatement is easily accomplished via subspace decomposition in the transform domain. The subspace decomposition is performed using singular value decomposition (SVD). The order of the transform domain SVD filter required to achieve the desired degree of noise abatement is compared to that of a suboptimal Wiener filter using DCT. Since the Wiener filter assumes both the signal and noise structures to be statistical, with a priori known second-order characteristics, it yields a biased estimate of the ECG beat as compared to the SVD filter for a given value of mean-square error (mse). The filter order required for performing the subspace smoothing is shown to exceed a certain minimal value for which the mse profile of the SVD filter follows the minimum-mean-quare error (mmse) performance warranted by the suboptimal Wiener filter. The effective filter order required for reproducing clinically significant features in the noisy ECG is then set by an upper bound derived by means of a finite precision linear perturbation model. A significant advantage resulting from the application of the proposed SVD filter lies in its ability to perform noise suppression independently on a single lead ECG record with only a limited number of data samples.

Entities:  

Mesh:

Year:  2000        PMID: 10851809     DOI: 10.1109/10.841337

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

1.  Real alerts and artifact classification in archived multi-signal vital sign monitoring data: implications for mining big data.

Authors:  Marilyn Hravnak; Lujie Chen; Artur Dubrawski; Eliezer Bose; Gilles Clermont; Michael R Pinsky
Journal:  J Clin Monit Comput       Date:  2015-10-05       Impact factor: 2.502

2.  Using Supervised Machine Learning to Classify Real Alerts and Artifact in Online Multisignal Vital Sign Monitoring Data.

Authors:  Lujie Chen; Artur Dubrawski; Donghan Wang; Madalina Fiterau; Mathieu Guillame-Bert; Eliezer Bose; Ata M Kaynar; David J Wallace; Jane Guttendorf; Gilles Clermont; Michael R Pinsky; Marilyn Hravnak
Journal:  Crit Care Med       Date:  2016-07       Impact factor: 7.598

3.  A subspace decomposition approach toward recognizing valid pulsatile signals.

Authors:  Shadnaz Asgari; Peng Xu; Marvin Bergsneider; Xiao Hu
Journal:  Physiol Meas       Date:  2009-10-01       Impact factor: 2.833

4.  Suppression of electromyogram interference on the electrocardiogram by transform domain denoising.

Authors:  N Nikolaev; A Gotchev; K Egiazarian; Z Nikolov
Journal:  Med Biol Eng Comput       Date:  2001-11       Impact factor: 3.079

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.