Literature DB >> 17354636

Pinhole SPECT with different data acquisition geometries: usefulness of unified projection operators in homogeneous coordinates.

Yuchuan Wang1, Benjamin M W Tsui.   

Abstract

To further improve pinhole single photon emission computed tomography (SPECT) imaging, there have been increasing interests in the use of nonstandard collimator designs and/or acquisition geometries. Homogeneous coordinates provide a compact and convenient framework to unify the geometric descriptions of the projection operators for these different imaging geometries, which may facilitate the implementation of iterative reconstruction algorithms and the investigation of crucial geometric calibration problems in pinhole SPECT. In this work, these advantages were demonstrated through three examples, namely, multipinhole SPECT, pinhole SPECT with a helical scanning orbit, and pinhole SPECT with dual detectors. Specifically, we showed adaptable implementations of iterative image reconstruction algorithms and translatable strategies for efficient geometric calibrations through unifying projection operators of the aforementioned imaging geometries. Notably, the unified geometric descriptions of multipinhole and single pinhole projection operators allowed us to derive that one can effectively calibrate a multipinhole geometry using only two point sources without measuring their distance. Experimental studies were performed to demonstrate the validity of our approaches, which may be extended to other pinhole SPECT and cone-beam X-ray computed tomography imaging geometries.

Mesh:

Year:  2007        PMID: 17354636     DOI: 10.1109/TMI.2006.887372

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  9 in total

1.  Small-animal molecular imaging methods.

Authors:  Robert A de Kemp; Frederick H Epstein; Ciprian Catana; Benjamin M W Tsui; Erik L Ritman
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

2.  Geometric characterization of multi-axis multi-pinhole SPECT.

Authors:  Frank P DiFilippo
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

3.  Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT.

Authors:  Chia-Lin Chen; Yuchuan Wang; Jason J S Lee; Benjamin M W Tsui
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

4.  A line-source method for aligning on-board and other pinhole SPECT systems.

Authors:  Susu Yan; James Bowsher; Fang-Fang Yin
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

5.  Evaluation of a multi-pinhole collimator for imaging small animals with different sizes.

Authors:  Greta S P Mok; Jianhua Yu; Yong Du; Yuchuan Wang; Benjamin M W Tsui
Journal:  Mol Imaging Biol       Date:  2012-02       Impact factor: 3.488

6.  The effects of object activity distribution on multiplexing multi-pinhole SPECT.

Authors:  Greta S P Mok; Benjamin M W Tsui; Freek J Beekman
Journal:  Phys Med Biol       Date:  2011-04-01       Impact factor: 3.609

7.  Development and validation of a Monte Carlo simulation tool for multi-pinhole SPECT.

Authors:  Greta S P Mok; Yong Du; Yuchuan Wang; Eric C Frey; Benjamin M W Tsui
Journal:  Mol Imaging Biol       Date:  2009-09-25       Impact factor: 3.488

8.  Toward quantitative small animal pinhole SPECT: assessment of quantitation accuracy prior to image compensations.

Authors:  Chia-Lin Chen; Yuchuan Wang; Jason J S Lee; Benjamin M W Tsui
Journal:  Mol Imaging Biol       Date:  2008-12-02       Impact factor: 3.488

9.  Feasibility of whole-body functional mouse imaging using helical pinhole SPECT.

Authors:  Scott D Metzler; Sreekanth Vemulapalli; Ronald J Jaszczak; Gamal Akabani; Bennett B Chin
Journal:  Mol Imaging Biol       Date:  2009-06-12       Impact factor: 3.488

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.