A comparative study of high-resolution cone beam computed tomography and charge-coupled device sensors for detecting caries.

S M Young1, J T Lee, R J Hodges, T-L Chang, D A Elashoff, S C White.   

Abstract

OBJECTIVES: Conventional radiographic imaging of teeth underestimates the presence of caries. The objective of this study was to compare the efficacy of high-resolution cone beam CT (CBCT) images and conventional charge-coupled device (CCD) images for detecting proximal and occlusal caries.
METHODS: Non-restored, extracted human permanent premolar and molar teeth were mounted and then imaged with a 3DX Accuitomo and a CCD. We selected 92 occlusal and 100 proximal surfaces for raters to score. Of these, 36 and 25, respectively, had lesions extending into dentin. Using a five-step confidence scale, eight practising dentists evaluated the images for the presence of caries in dentin using both modalities. Actual presence and extent of caries was established with microCT imaging.
RESULTS: For proximal surface lesions extending into dentin, the average sensitivity score using 3DX images (0.61) was almost twice that of CCD images (0.33) and the difference was significant. The specificity values for both systems were high and not significantly different from each other. For occlusal surfaces, raters detected significantly more lesions in the enamel or dentin when using the 3DX images than when using CCD images. However, the raters also had significantly lower average specificity scores for the 3DX images compared with the CCD images for lesions at both depths.
CONCLUSIONS: Practising dentists were able to improve their detection of proximal-surface caries extending into the dentin, but not occlusal caries, using 3DX high-resolution cone beam CT images compared with CCD images.

Entities:  

Mesh:

Year:  2009        PMID: 19767514     DOI: 10.1259/dmfr/88765582

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  21 in total

Review 1.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

2.  Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions.

Authors:  Jun-Ge Cheng; Zhi-Ling Zhang; Xiao-Yan Wang; Zu-Yan Zhang; Xu-Chen Ma; Gang Li
Journal:  Clin Oral Investig       Date:  2011-07-30       Impact factor: 3.573

3.  Validity of wax and acrylic as soft-tissue simulation materials used in in vitro radiographic studies.

Authors:  L Schropp; N S Alyass; A Wenzel; A Stavropoulos
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

4.  Proximal caries detection accuracy using intraoral bitewing radiography, extraoral bitewing radiography and panoramic radiography.

Authors:  K Kamburoglu; E Kolsuz; S Murat; S Yüksel; T Ozen
Journal:  Dentomaxillofac Radiol       Date:  2012-09       Impact factor: 2.419

5.  Detection of cavitated approximal surfaces using cone beam CT and intraoral receptors.

Authors:  A Wenzel; E Hirsch; J Christensen; L H Matzen; G Scaf; M Frydenberg
Journal:  Dentomaxillofac Radiol       Date:  2012-07-27       Impact factor: 2.419

6.  Performance of a photostimulable storage phosphor digital system with or without the sharpen filter and cone beam CT for detecting approximal enamel subsurface demineralization.

Authors:  M D F Belém; C P M Tabchoury; R I Ferreira-Santos; F C Groppo; F Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2013-02-14       Impact factor: 2.419

7.  The influence of amalgam fillings on the detection of approximal caries by cone beam CT: in vitro study.

Authors:  T Kulczyk; M Dyszkiewicz Konwińska; M Owecka; J Krzyżostaniak; A Surdacka
Journal:  Dentomaxillofac Radiol       Date:  2014-07-02       Impact factor: 2.419

8.  Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT.

Authors:  İsmail H Baltacıoĝlu; Hakan Eren; Yasemin Yavuz; Kıvanç Kamburoğlu
Journal:  Dentomaxillofac Radiol       Date:  2016-07-04       Impact factor: 2.419

9.  Occlusal caries depth measurements obtained by five different imaging modalities.

Authors:  Kivanç Kamburoğlu; Hakan Kurt; Eray Kolsuz; Bengi Öztaş; Ilkan Tatar; Hakan Hamdi Çelik
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

Review 10.  Cone beam computed tomography in paediatric dentistry: overview of recent literature.

Authors:  J K M Aps
Journal:  Eur Arch Paediatr Dent       Date:  2013-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.