Literature DB >> 19762457

A new reference line for the brain CT: the tuberculum sellae-occipital protuberance line is parallel to the anterior/posterior commissure line.

Y I Kim1, K J Ahn, Y A Chung, B S Kim.   

Abstract

BACKGROUND AND
PURPOSE: CT and MR imaging of the brain have diverged reference lines. Modified Talairach anterior/posterior commissure (ACPC) line is widely accepted as the standard for clinical brain MR imaging, while orbitomeatal line (OML) is used for CT. This study sought to determine an appropriate reference line for brain CT parallel to the ACPC line.
MATERIALS AND METHODS: We measured the angles between the ACPC line and the OML, the line connecting the tuberculum sellae and the internal occipital protuberance (TS-IOP line), and the line connecting the tuberculum sellae and the external occipital protuberance (TS-EOP line) on midsagittal brain MR images of 223 patients. In addition, with the hard palate as the basis, the angles to the ACPC line in the brain MR images and new reference line on the brain CT images from the same patient were measured, and the difference between the 2 angles was calculated in 30 patients. In the same method, the angles to the OML in the brain CT images and the ACPC line on the brain MR images were measured, and their difference was calculated in 30 patients. Then the 2 difference values were compared with verification of the new reference line.
RESULTS: The angles between the ACPC line and both the TS-IOP line (0.0 degrees +/- 4.0 degrees ) and the TS-EOP line (0.8 degrees +/- 3.2 degrees ) were significantly smaller than the angles between the ACPC line and the OML (-12.6 degrees +/- 4.2 degrees ; P < .05). In actual scanned images, the angle differences between the TS-OP (TS-IOP + TS-EOP) line and the ACPC line (0.3 degrees +/- 4.5 degrees ) were statistically smaller than the angles between the OML and the ACPC line (-6.6 degrees +/- 3.9 degrees ; P < .05).
CONCLUSIONS: TS-OP lines are nearly parallel to the ACPC line.

Entities:  

Mesh:

Year:  2009        PMID: 19762457      PMCID: PMC7051527          DOI: 10.3174/ajnr.A1676

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  10 in total

1.  Optimizing accuracy in magnetic resonance imaging-guided stereotaxis: a technique with validation based on the anterior commissure-posterior commissure line.

Authors:  C G diPierro; P C Francel; T R Jackson; T Kamiryo; E R Laws
Journal:  J Neurosurg       Date:  1999-01       Impact factor: 5.115

2.  Multiparametric color-encoded brain MR imaging in Talairach space.

Authors:  Kenneth L Weiss; Qian Dong; William J Weadock; Robert C Welsh; Gaurang V Shah
Journal:  Radiographics       Date:  2002 Mar-Apr       Impact factor: 5.333

3.  CT brain prescriptions in Talairach space: a new clinical standard.

Authors:  Kenneth L Weiss; Judd Storrs; Jane L Weiss; William Strub
Journal:  AJNR Am J Neuroradiol       Date:  2004-02       Impact factor: 3.825

4.  Cranial CT artifacts and gantry angulation.

Authors:  C Rozeik; O Kotterer; J Preiss; M Schütz; W Dingler; H K Deininger
Journal:  J Comput Assist Tomogr       Date:  1991 May-Jun       Impact factor: 1.826

5.  Gantry angulation in brain CT: dosage implications, effect on posterior fossa artifacts, and current international practice.

Authors:  L J Yeoman; L Howarth; A Britten; A Cotterill; E J Adam
Journal:  Radiology       Date:  1992-07       Impact factor: 11.105

6.  Neurophysiological evaluation of the optimum target in gamma thalamotomy: indirect evidence.

Authors:  Sumito Sato; Chihiro Ohye; Tohru Shibazaki; Akira Zama; Xiaodong Cai
Journal:  Stereotact Funct Neurosurg       Date:  2005-08-03       Impact factor: 1.875

7.  The glabella-inion line as a baseline for CT scanning of the brain.

Authors:  A Tokunaga; M Takase; K Otani
Journal:  Neuroradiology       Date:  1977-09-30       Impact factor: 2.804

8.  Modified Talairach landmarks.

Authors:  W L Nowinski
Journal:  Acta Neurochir (Wien)       Date:  2001-10       Impact factor: 2.216

9.  Clinical brain MR imaging prescriptions in Talairach space: technologist- and computer-driven methods.

Authors:  Kenneth L Weiss; Hai Pan; Judd Storrs; William Strub; Jane L Weiss; Li Jia; O Petter Eldevik
Journal:  AJNR Am J Neuroradiol       Date:  2003-05       Impact factor: 3.825

10.  A reliable MR measurement of medial temporal lobe width from the Sunnybrook Dementia Study.

Authors:  F Q Gao; S E Black; F S Leibovitch; D J Callen; N J Lobaugh; J P Szalai
Journal:  Neurobiol Aging       Date:  2003 Jan-Feb       Impact factor: 4.673

  10 in total
  6 in total

1.  Usefulness of the frontal lobe bottom and cerebellum tuber vermis line as an alternative clue to set the axial angle parallel to the AC-PC line in I-123 IMP SPECT imaging: a retrospective study.

Authors:  Yasuhiro Inokuchi; Saki Koya; Masahiro Uematsu; Tsuneyuki Takashina
Journal:  Radiol Phys Technol       Date:  2019-09-18

2.  Toward automatic reformation at the orbitomeatal line in head computed tomography using object detection algorithm.

Authors:  Shota Ichikawa; Hideki Itadani; Hiroyuki Sugimori
Journal:  Phys Eng Sci Med       Date:  2022-07-06

3.  Localization of orofacial representation in the corona radiata, internal capsule and cerebral peduncle in Macaca mulatta.

Authors:  R J Morecraft; A Binneboese; K S Stilwell-Morecraft; J Ge
Journal:  J Comp Neurol       Date:  2017-08-02       Impact factor: 3.215

4.  Evaluation of Concomitant Orbital Floor Fractures in Patients with Head Trauma Using Conventional Head CT Scan: A Retrospective Study at a Level II Trauma Center.

Authors:  Li-Kuo Huang; Hsi-Feng Tu; Liang-De Jiang; Ying-Yuan Chen; Chih-Yuan Fu
Journal:  J Clin Med       Date:  2019-11-02       Impact factor: 4.241

5.  A new reference line for coronal head CT to align with MRI: development of a standardised approach.

Authors:  Kerem Ozturk; Anthony Spano; David Nascene
Journal:  Neuroradiol J       Date:  2020-11-11

6.  A new brain CT reference line: the lower eyelid to the inner occipital base line closely parallels the Talairach-Tournoux line.

Authors:  Hiroshi Ishizaka; Minoru Naka; Hiroyuki Nagase; Katsumi Yanagisawa; Toshio Kubota; Hideo Morita; Yoshito Tsushima
Journal:  Acta Radiol Open       Date:  2020-01-27
  6 in total