Literature DB >> 19722788

Immediate versus one-stage restoration of small-diameter implants for a single missing maxillary lateral incisor: a 3-year randomized clinical trial.

Marco Degidi1, Diego Nardi, Adriano Piattelli.   

Abstract

BACKGROUND: The aim of this study was to compare the bone loss pattern and soft tissue healing of immediately versus one-stage loaded 3.0-mm-diameter implants in cases involving a single missing lateral maxillary incisor.
METHODS: Sixty patients with a missing lateral incisor in the maxilla were randomized to one of the treatments: 30 patients in the immediate-restoration group and 30 patients in the one-stage group. All implants were placed in healed sites and had to be inserted with a torque >25 Ncm. The implants in the immediate-restoration group were fitted with a non-occluding temporary crown on the day of surgery. Both groups received a full occluding final crown 6 months after surgery. Mean marginal bone loss, probing depth, and bleeding on probing were assessed at 6-, 12-, 24-, and 36-month follow-up examinations by a masked examiner.
RESULTS: Sixty 3.0-mm-diameter implants were placed between July 2003 and February 2006; 27 (45.0%) were in men, and 33 (55.0%) were in women. All implants osseointegrated and were clinically stable at the 6-month follow-up. No statistically significant differences were observed for bleeding or plaque index. No implant fractures occurred. At the 36-month follow-up, the accumulated mean marginal bone loss and probing depth were 0.85 +/- 0.71 mm and 1.91 +/- 0.59 mm, respectively, for the immediate-loading group (n = 30) and 0.75 +/- 0.63 mm and 2.27 +/- 0.81 mm, respectively, for the one-stage group (n = 30). There was no statistically significant difference (P >0.05) for the tested outcome measures between the two procedures.
CONCLUSIONS: In the rehabilitation of a single missing lateral maxillary incisor, no statistically significant difference was assessed between immediately and one-stage restored small-diameter implants with regard to implant survival, mean marginal bone loss, and probing depth. Three-millimeter-diameter implants proved to be a predictable treatment option in our test and control groups if a strict clinical protocol was followed.

Entities:  

Mesh:

Year:  2009        PMID: 19722788     DOI: 10.1902/jop.2009.090153

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  10 in total

Review 1.  Role of implant diameter on long-term survival of dental implants placed in posterior maxilla: a systematic review.

Authors:  Fawad Javed; Georgios E Romanos
Journal:  Clin Oral Investig       Date:  2014-11-01       Impact factor: 3.573

2.  Minimally invasive transmucosal insertion and immediate provisonalization of one-piece implant in partially edentulous posterior mandible.

Authors:  Narpatsingh Rajput; Siyad K P; Rathinavelu G; Chandrasekaran S C; Jumshad Mohammed
Journal:  J Clin Diagn Res       Date:  2013-09-10

3.  Biomechanical effects of the implant material and implant-abutment interface in immediately loaded small-diameter implants.

Authors:  Aaron Yu-Jen Wu; Heng-Li Huang; Jui-Ting Hsu; Winston Chee
Journal:  Clin Oral Investig       Date:  2013-09-03       Impact factor: 3.573

4.  Photoelastic stress analysis in prosthetic implants of different diameters: mini, narrow, standard or wide.

Authors:  Marcelo Coelho Goiato; Alves Aldiéris Pesqueira; Daniela Micheline Dos Santos; Marcela Filié Haddad; Amália Moreno
Journal:  J Clin Diagn Res       Date:  2014-09-20

Review 5.  Interventions for replacing missing teeth: different times for loading dental implants.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Hassan Maghaireh; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2013-03-28

6.  Immediate provisionalization in the esthetic zone: 1-year interim results from a prospective single-cohort multicenter study evaluating 3.0-mm-diameter tapered implants.

Authors:  Martin Kolinski; Pablo Hess; Sonia Leziy; Bertil Friberg; Gionata Bellucci; Davide Trisciuoglio; Wilfried Wagner; Maximilian Moergel; Alessandro Pozzi; Jörg Wiltfang; Eleonore Behrens; Werner Zechner; Christoph Vasak; Paul Weigl
Journal:  Clin Oral Investig       Date:  2018-02-03       Impact factor: 3.573

7.  A 5-year prospective clinical trial on short implants (6 mm) for single tooth replacement in the posterior maxilla: immediate versus delayed loading.

Authors:  Mustafa Ayna; Bastian Wessing; Ralf Gutwald; Andreas Neff; Thomas Ziebart; Yahya Açil; Jörg Wiltfang; Aydin Gülses
Journal:  Odontology       Date:  2018-07-17       Impact factor: 2.634

Review 8.  Narrow-diameter implants: are they a predictable treatment option? A literature review.

Authors:  José-Luis Sierra-Sánchez; Amparo Martínez-González; Fernando García-Sala Bonmatí; José-Félix Mañes-Ferrer; Alejandro Brotons-Oliver
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2014-01-01

9.  Occlusal rehabilitation in patients with congenitally missing teeth-dental implants, conventional prosthetics, tooth autotransplants, and preservation of deciduous teeth-a systematic review.

Authors:  Hendrik Terheyden; Falk Wüsthoff
Journal:  Int J Implant Dent       Date:  2015-11-18

10.  Immediate loading of short implants: A systematic review.

Authors:  Mahdi Hadilou; Pooya Ebrahimi; Behnaz Karimzadeh; Ashkan Ghaffary; Leila Gholami; Zahra Fathifar
Journal:  J Adv Periodontol Implant Dent       Date:  2021-03-06
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.