Literature DB >> 30019170

A 5-year prospective clinical trial on short implants (6 mm) for single tooth replacement in the posterior maxilla: immediate versus delayed loading.

Mustafa Ayna1, Bastian Wessing2, Ralf Gutwald3, Andreas Neff4, Thomas Ziebart4, Yahya Açil5, Jörg Wiltfang5, Aydin Gülses6.   

Abstract

The aim of this paper was to demonstrate the treatment outcomes following immediate functional loading concept of short implants inserted for single tooth replacement in the posterior maxilla. The study was performed on 63 patients who received short (6 mm) implants for single tooth replacement in the posterior maxilla. Forty-eight patients underwent immediate functional concept, whereas 15 of the implants were loaded 3 months after insertion. The patients were evaluated for up to 5 years after prosthesis completion. The endpoints included the evaluation of implant survival rate, crown length, bone resorption, plaque accumulation (PI), bleeding on probing (BOP), periodontal probing depth (PPD) and assessment of oral health impact profile (OHIP). At the end of the follow-up period of 5 years, three implants (6.3%) from the immediate loading group have failed during the observation period. Bone loss was significantly lower in the delayed loading group compared to the immediately loaded implants. At the end of the second year, BOP values were higher in the immediately loaded group. Throughout the observation period, PI values in the group with immediate loading were higher. PPD increased consistently and during the first 3 years in the immediate loading group. As a conclusion, short implants inserted for single tooth replacement at the posterior maxilla presented with satisfactory clinical outcomes in both immediate and delayed loading concepts. However, immediately loaded implants presented with an increased bone loss and higher BOP values. As assessed by the OHIP score, a subjective improvement was observed in both groups without significant differences.

Entities:  

Keywords:  Delayed; Immediate; Implant; Maxilla; Temporary

Mesh:

Year:  2018        PMID: 30019170     DOI: 10.1007/s10266-018-0378-x

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  41 in total

1.  The effects of surface roughness and type of denture acrylic on biofilm formation by Streptococcus oralis in a constant depth film fermentor.

Authors:  T D Morgan; M Wilson
Journal:  J Appl Microbiol       Date:  2001-07       Impact factor: 3.772

Review 2.  Optimal implant stabilization in low density bone.

Authors:  H Martinez; M Davarpanah; P Missika; R Celletti; R Lazzara
Journal:  Clin Oral Implants Res       Date:  2001-10       Impact factor: 5.977

Review 3.  Use of radiographs in evaluating success, stability and failure in implant dentistry.

Authors:  U Brägger
Journal:  Periodontol 2000       Date:  1998-06       Impact factor: 7.589

4.  Immediate loading of single-tooth implants in the posterior region.

Authors:  Marcus Abboud; Bernd Koeck; Helmut Stark; Gerhard Wahl; Roswitha Paillon
Journal:  Int J Oral Maxillofac Implants       Date:  2005 Jan-Feb       Impact factor: 2.804

5.  Implant success, survival, and failure: the International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference.

Authors:  Carl E Misch; Morton L Perel; Hom-Lay Wang; Gilberto Sammartino; Pablo Galindo-Moreno; Paolo Trisi; Marius Steigmann; Alberto Rebaudi; Ady Palti; Michael A Pikos; D Schwartz-Arad; Joseph Choukroun; Jose-Luis Gutierrez-Perez; Gaetano Marenzi; Dimosthenis K Valavanis
Journal:  Implant Dent       Date:  2008-03       Impact factor: 2.454

6.  German short forms of the Oral Health Impact Profile.

Authors:  Mike T John; Diana L Miglioretti; Linda LeResche; Thomas D Koepsell; Philippe Hujoel; Wolfgang Micheelis
Journal:  Community Dent Oral Epidemiol       Date:  2006-08       Impact factor: 3.383

7.  The influence of substratum topography on bacterial adhesion to polymethyl methacrylate.

Authors:  R L Taylor; J Verran; G C Lees; A J Ward
Journal:  J Mater Sci Mater Med       Date:  1998-01       Impact factor: 3.896

8.  Bacterial adhesion of Streptococcus mutans to provisional fixed prosthodontic material.

Authors:  Ralf Buergers; Martin Rosentritt; Gerhard Handel
Journal:  J Prosthet Dent       Date:  2007-12       Impact factor: 3.426

9.  A 10-year prospective study of ITI dental implants placed in the posterior region. II: Influence of the crown-to-implant ratio and different prosthetic treatment modalities on crestal bone loss.

Authors:  Rafael Juan Blanes; Jean Pierre Bernard; Zulema Maria Blanes; Urs Christoph Belser
Journal:  Clin Oral Implants Res       Date:  2007-08-13       Impact factor: 5.977

10.  Adherence of Streptococcus mutans to various restorative materials in a continuous flow system.

Authors:  S Eick; E Glockmann; B Brandl; W Pfister
Journal:  J Oral Rehabil       Date:  2004-03       Impact factor: 3.837

View more
  4 in total

1.  A clinical study on the 6-year outcomes of immediately loaded three implants for completely edentulous mandibles: "the all-on-3 concept".

Authors:  Mustafa Ayna; Keyvan Sagheb; Ralf Gutwald; Henning Wieker; Christian Flörke; Yahya Açil; Jörg Wiltfang; Aydin Gülses
Journal:  Odontology       Date:  2019-07-05       Impact factor: 2.634

2.  Short versus Standard Length Implants with Sinus Floor Elevation for the Atrophic Posterior Maxilla.

Authors:  Eik Schiegnitz; Nina Hill; Keyvan Sagheb; Jochem König; Kawe Sagheb; Bilal Al-Nawas
Journal:  Acta Stomatol Croat       Date:  2022-06

3.  Comparative Analysis of Peri-Implant Bone Loss in Extra-Short, Short, and Conventional Implants. A 3-Year Retrospective Study.

Authors:  Daycelí Estévez-Pérez; Naia Bustamante-Hernández; Carlos Labaig-Rueda; María Fernanda Solá-Ruíz; José Amengual-Lorenzo; Fernando García-Sala Bonmatí; Álvaro Zubizarreta-Macho; Rubén Agustín-Panadero
Journal:  Int J Environ Res Public Health       Date:  2020-12-11       Impact factor: 3.390

4.  Immediate loading of short implants: A systematic review.

Authors:  Mahdi Hadilou; Pooya Ebrahimi; Behnaz Karimzadeh; Ashkan Ghaffary; Leila Gholami; Zahra Fathifar
Journal:  J Adv Periodontol Implant Dent       Date:  2021-03-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.