PURPOSE: To evaluate the role of C-arm CT for on-line fluoroscopy in regional transarterial chemoperfusion (TACP) and chemo-embolization (TPCE) of primary and secondary malignant thoracic lesions.
MATERIALS AND METHODS: From September 2008 to March 2009 a total of 31 patients (20 males and 11 females, average age: 61.7 years, range 22-84 years) with 53 thoracic malignant lesions from different origins (primary or secondary pulmonary carcinoma n=37, pleural mesothelioma n=16) were treated with TACP or TPCE using flat-detector CT (FD-CT). C-arm CT of the latest generation was used to localize the lesion before local chemotherapy (Artis Zeego, Siemens, Erlangen). For TACP a 220 degrees rotation and a volume of 150 ml (ratio of 1:2 contrast/normal saline), delay 2 s and flow 12 ml/s was used. For TPCE a volume of 75 ml (ratio of 1:2 contrast/normal saline), delay 2 s and flow 3 ml/s was used.
RESULTS: TPCE C-arm CT allowed the evaluation of the degree of perfusion of the tumor and the geographic areas of enhancement correlated with the post-interventional lipiodol uptake in MSCT. In TACP the intercostal arteries involved could be visualized and in 30% of interventions the catheter had to be repositioned for the following intervention.
CONCLUSION: C-arm CT provides additional information on the vascular characteristics and perfusion of pulmonary lesions resulting in a change of interventional strategy in a relevant number of patients.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19707738     DOI: 10.1007/s00117-009-1863-6

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  18 in total

1.  Flat-panel cone-beam computed tomography for image-guided radiation therapy.

Authors:  David A Jaffray; Jeffrey H Siewerdsen; John W Wong; Alvaro A Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-08-01       Impact factor: 7.038

2.  Evaluation of vascular supply with cone-beam computed tomography during intraarterial chemotherapy for a skull base tumor.

Authors:  Reiichi Ishikura; Kumiko Ando; Yuki Nagami; Satoshi Yamamoto; Koui Miura; Ajaya Raj Pande; Tosyiko Yamano; Shozo Hirota; Norio Nakao
Journal:  Radiat Med       Date:  2006-06

3.  Cone-beam CT with flat-panel-detector digital angiography system: early experience in abdominal interventional procedures.

Authors:  Shozo Hirota; Norio Nakao; Satoshi Yamamoto; Kaoru Kobayashi; Hiroaki Maeda; Reiichi Ishikura; Koui Miura; Kiyoshi Sakamoto; Ken Ueda; Rika Baba
Journal:  Cardiovasc Intervent Radiol       Date:  2006 Nov-Dec       Impact factor: 2.740

4.  Impalpable pulmonary nodules with ground-glass opacity: Success for making pathologic sections with preoperative marking by lipiodol.

Authors:  Koei Ikeda; Hiroaki Nomori; Takeshi Mori; Hironori Kobayashi; Kazunori Iwatani; Kentaro Yoshimoto; Ko-ichi Kawanaka
Journal:  Chest       Date:  2007-02       Impact factor: 9.410

5.  Usefulness of cone-beam volume CT with flat panel detectors in conjunction with catheter angiography for transcatheter arterial embolization.

Authors:  Shingo Kakeda; Yukunori Korogi; Norihiro Ohnari; Junji Moriya; Nobuhiro Oda; Kazuyoshi Nishino; Wataru Miyamoto
Journal:  J Vasc Interv Radiol       Date:  2007-12       Impact factor: 3.464

Review 6.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

7.  Effect of C-arm angiographic CT on transcatheter arterial chemoembolization of liver tumors.

Authors:  Sumeet Virmani; Robert K Ryu; Kent T Sato; Robert J Lewandowski; Laura Kulik; Mary F Mulcahy; Andrew C Larson; Riad Salem; Reed A Omary
Journal:  J Vasc Interv Radiol       Date:  2007-10       Impact factor: 3.464

8.  3D C-arm as an alternative modality to CT in postmortem imaging: technical feasibility.

Authors:  Philipp Pohlenz; Marco Blessmann; Lars Oesterhelweg; Christan R Habermann; Philipp G C Begemann; Christian Schmidgunst; Felix Blake; Dirk Schulze; Klaus Püschel; Rainer Schmelzle; Max Heiland
Journal:  Forensic Sci Int       Date:  2007-07-20       Impact factor: 2.395

9.  Experimental study of intracranial hematoma detection with flat panel detector C-arm CT.

Authors:  H Arakawa; M P Marks; H M Do; D M Bouley; N Strobel; T Moore; R Fahrig
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-17       Impact factor: 3.825

10.  The usefulness of three-dimensional angiography with a flat panel detector of direct conversion type in a transcatheter arterial chemoembolization procedure for hepatocellular carcinoma: initial experience.

Authors:  Shingo Kakeda; Yukunori Korogi; Yoshihisa Hatakeyama; Norihiro Ohnari; Nobuhiro Oda; Kazuyoshi Nishino; Wataru Miyamoto
Journal:  Cardiovasc Intervent Radiol       Date:  2008 Mar-Apr       Impact factor: 2.740

View more
  4 in total

1.  Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments.

Authors:  Tobias Penzkofer; Peter Isfort; Philipp Bruners; Christian Wiemann; Yiannis Kyriakou; Willi A Kalender; Rolf W Günther; Thomas Schmitz-Rode; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2010-06-23       Impact factor: 5.315

2.  Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection.

Authors:  Virginie Cordemans; Ludovic Kaminski; Xavier Banse; Bernard G Francq; Olivier Cartiaux
Journal:  Eur Spine J       Date:  2017-05-20       Impact factor: 3.134

3.  Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study.

Authors:  Boris Schulz; Katrin Eichler; Petra Siebenhandl; Tatjana Gruber-Rouh; Christoph Czerny; Thomas Josef Vogl; Stephan Zangos
Journal:  Eur Radiol       Date:  2012-07-21       Impact factor: 5.315

4.  Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study.

Authors:  Wolfgang Hohenforst-Schmidt; Rosemarie Banckwitz; Paul Zarogoulidis; Thomas Vogl; Kaid Darwiche; Eugene Goldberg; Haidong Huang; Michael Simoff; Qiang Li; Robert Browning; Lutz Freitag; J Francis Turner; Patrick Le Pivert; Lonny Yarmus; Konstantinos Zarogoulidis; Johannes Brachmann
Journal:  J Cancer       Date:  2014-02-06       Impact factor: 4.207

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.