Literature DB >> 18057285

Usefulness of cone-beam volume CT with flat panel detectors in conjunction with catheter angiography for transcatheter arterial embolization.

Shingo Kakeda1, Yukunori Korogi, Norihiro Ohnari, Junji Moriya, Nobuhiro Oda, Kazuyoshi Nishino, Wataru Miyamoto.   

Abstract

PURPOSE: To assess the usefulness of cone-beam volume computed tomography (CT) (cone-beam CT) with use of flat panel detectors of the direct conversion type in conjunction with conventional digital subtraction angiography (DSA) in the diagnosis and treatment of patients with hepatocellular carcinoma (HCC).
MATERIALS AND METHODS: Forty-nine consecutive patients (52 suspicious lesions) were prospectively examined. All patients underwent intraarterial rotational angiography with a flat panel detector system, and the cone-beam CT scans were reconstructed from the volume data set. The authors evaluated the diagnostic quality of cone-beam CT for the transcatheter arterial chemoembolization (TACE) procedure.
RESULTS: The diagnostic quality of conventional DSA plus cone-beam CT with regard to tumor staining was superior to that of DSA alone. Cone-beam CT showed tumor staining in five lesions that were difficult to diagnose with confidence on the basis of the DSA findings alone. The extent of contrast medium perfusion was sufficiently visualized on all cone-beam CT scans at the tip of the catheter positioned in either the segmental or subsegmental hepatic arteries. In 42 of the 52 lesions (81%), cone-beam CT provided additional useful information for therapeutic decision making or TACE compared with DSA.
CONCLUSIONS: Intraarterial cone-beam CT with a flat panel detector can provide clinically acceptable image quality in the assessment of HCC, thereby improving the detection of tumor staining due to HCC and the visualization of the extent of contrast medium perfusion.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18057285     DOI: 10.1016/j.jvir.2007.08.003

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  44 in total

1.  Flat-panel versus 64-channel computed tomography for in vivo quantitative characterization of aortic atherosclerotic plaques.

Authors:  Ibrahim Aboshady; Dianna D Cody; Evan M Johnson; Amir Gahremanpour; Deborah Vela; Kamal G Khalil; Herbert L Dupont; James T Willerson; L Maximilian Buja; Gregory W Gladish
Journal:  Int J Cardiol       Date:  2010-12-24       Impact factor: 4.164

2.  Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation.

Authors:  Qeumars Mustafa Hamie; Adrian Raoul Kobe; Leif Mietzsch; Michael Manhart; Gilbert Dominique Puippe; Thomas Pfammatter; Roman Guggenberger
Journal:  Eur Radiol       Date:  2017-07-14       Impact factor: 5.315

3.  [Image guiding techniques and navigation for TACE, SIRT and TIPS].

Authors:  R Adamus; M Pfister; M Uder; R W Loose
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

4.  [C-arm computed tomography for transarterial chemoperfusion and chemo-embolization of thoracic lesions].

Authors:  T J Vogl; N N Naguib; N-E Nour-Eldin; T Lehnert; E Mbalisike
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

5.  Hepatoma feeding arteriogram created by CT during aortography using IVR 64-multidetector-row CT for catheterization in transcatheter arterial chemoembolization for hepatocellular carcinoma.

Authors:  Hiroki Minamiguchi; Nobuyuki Kawai; Morio Sato; Akira Ikoma; Hiroki Sanda; Kouhei Nakata; Fumihiro Tanaka; Motoki Nakai; Tetsuo Sonomura; Kazuhiro Murotani; Seiki Hosokawa; Tadayoshi Nishioku
Journal:  Jpn J Radiol       Date:  2013-05-09       Impact factor: 2.374

Review 6.  Efficacy of cone-beam computed tomography during transcatheter arterial chemoembolization for hepatocellular carcinoma.

Authors:  Shiro Miyayama; Masashi Yamashiro; Yuki Hattori; Nobuaki Orito; Ken Matsui; Kazunobu Tsuji; Miki Yoshida; Osamu Matsui
Journal:  Jpn J Radiol       Date:  2011-07-24       Impact factor: 2.374

7.  Accurate and rapid identification of feeding arteries with multidetector-row angiography-assisted computed tomography for transarterial chemoembolization for hepatocellular carcinoma.

Authors:  Ken Takada; Hidenori Toyoda; Toshifumi Tada; Takanori Ito; Ryohei Hasegawa; Tatsuya Gotoh; Hironori Ichikawa; Yasuhiro Sone; Takashi Kumada
Journal:  J Gastroenterol       Date:  2015-03-21       Impact factor: 7.527

8.  Brain imaging with a flat detector C-arm : Technique and clinical interest of XperCT.

Authors:  M Söderman; D Babic; S Holmin; T Andersson
Journal:  Neuroradiology       Date:  2008-06-17       Impact factor: 2.804

9.  Tracking Navigation Imaging of Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma Using Three-Dimensional Cone-Beam CT Angiography.

Authors:  Yasunori Minami; Yukinobu Yagyu; Takamichi Murakami; Masatoshi Kudo
Journal:  Liver Cancer       Date:  2014-03       Impact factor: 11.740

10.  Visualization of gastric varices using angiographic C-arm CT during retrograde transvenous sclerotherapy.

Authors:  Jin Iwazawa; Shoichi Ohue; Hisashi Abe; Takashi Mitani
Journal:  Indian J Radiol Imaging       Date:  2010-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.