Design and performance evaluation of a coplanar multimodality scanner for rodent imaging.

E Lage1, J J Vaquero, A Sisniega, S España, G Tapias, M Abella, A Rodríguez-Ruano, J E Ortuño, A Udías, M Desco.   

Abstract

This work reports on the development and performance evaluation of the VrPET/CT, a new multimodality scanner with coplanar geometry for in vivo rodent imaging. The scanner design is based on a partial-ring PET system and a small-animal CT assembled on a rotatory gantry without axial displacement between the geometric centers of both fields of view (FOV). We report on the PET system performance based on the NEMA NU-4 protocol; the performance characteristics of the CT component are not included herein. The accuracy of inter-modality alignment and the imaging capability of the whole system are also evaluated on phantom and animal studies. Tangential spatial resolution of PET images ranged between 1.56 mm at the center of the FOV and 2.46 at a radial offset of 3.5 cm. The radial resolution varies from 1.48 mm to 1.88 mm, and the axial resolution from 2.34 mm to 3.38 mm for the same positions. The energy resolution was 16.5% on average for the entire system. The absolute coincidence sensitivity is 2.2% for a 100-700 keV energy window with a 3.8 ns coincident window. The scatter fraction values for the same settings were 11.45% for a mouse-sized phantom and 23.26% for a rat-sized phantom. The peak noise equivalent count rates were also evaluated for those phantoms obtaining 70.8 kcps at 0.66 MBq/cc and 31.5 kcps at 0.11 MBq/cc, respectively. The accuracy of inter-modality alignment is below half the PET resolution, and the image quality of biological specimens agrees with measured performance parameters. The assessment presented in this study shows that the VrPET/CT system is a good performance small-animal imager, while the cost derived from a partial ring detection system is substantially reduced as compared with a full-ring PET tomograph.

Entities:  

Mesh:

Year:  2009        PMID: 19700817     DOI: 10.1088/0031-9155/54/18/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Preclinical positron emission tomography scanner based on a monolithic annulus of scintillator: initial design study.

Authors:  Alexander V Stolin; Peter F Martone; Gangadhar Jaliparthi; Raymond R Raylman
Journal:  J Med Imaging (Bellingham)       Date:  2017-01-05

2.  Performance evaluation of PETbox: a low cost bench top preclinical PET scanner.

Authors:  Hui Zhang; Qinan Bao; Nam T Vu; Robert W Silverman; Richard Taschereau; Brittany N Berry-Pusey; Ali Douraghy; Fernando R Rannou; David B Stout; Arion F Chatziioannou
Journal:  Mol Imaging Biol       Date:  2011-10       Impact factor: 3.488

3.  Performance Characteristics of BGO Detectors for a Low Cost Preclinical PET Scanner.

Authors:  H Zhang; N T Vu; Q Bao; R W Silverman; B N Berry-Pusey; A Douraghy; D A Williams; F R Rannou; D B Stout; A F Chatziioannou
Journal:  IEEE Trans Nucl Sci       Date:  2010-06-01       Impact factor: 1.679

4.  NEMA NU 4-2008 comparison of preclinical PET imaging systems.

Authors:  Andrew L Goertzen; Qinan Bao; Mélanie Bergeron; Eric Blankemeyer; Stephan Blinder; Mario Cañadas; Arion F Chatziioannou; Katherine Dinelle; Esmat Elhami; Hans-Sonke Jans; Eduardo Lage; Roger Lecomte; Vesna Sossi; Suleman Surti; Yuan-Chuan Tai; Juan José Vaquero; Esther Vicente; Darin A Williams; Richard Laforest
Journal:  J Nucl Med       Date:  2012-06-14       Impact factor: 10.057

5.  NEMA NU-4 performance evaluation of PETbox4, a high sensitivity dedicated PET preclinical tomograph.

Authors:  Z Gu; R Taschereau; N T Vu; H Wang; D L Prout; R W Silverman; B Bai; D B Stout; M E Phelps; A F Chatziioannou
Journal:  Phys Med Biol       Date:  2013-05-10       Impact factor: 3.609

6.  Neuroimaging reveals distinct brain glucose metabolism patterns associated with morphine consumption in Lewis and Fischer 344 rat strains.

Authors:  Mª Luisa Soto-Montenegro; Verónica García-Vázquez; Nicolás Lamanna-Rama; Gonzalo López-Montoya; Manuel Desco; Emilio Ambrosio
Journal:  Sci Rep       Date:  2022-03-17       Impact factor: 4.379

Review 7.  The motivations and methodology for high-throughput PET imaging of small animals in cancer research.

Authors:  Nicolas Aide; Eric P Visser; Stéphanie Lheureux; Natacha Heutte; Istvan Szanda; Rodney J Hicks
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-07-13       Impact factor: 9.236

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.