Literature DB >> 19700349

Uncalibrated radial and femoral arterial pressure waveform analysis for continuous cardiac output measurement: an evaluation in cardiac surgery patients.

Christoph K Hofer1, Danny Button, Luc Weibel, Michele Genoni, Andreas Zollinger.   

Abstract

OBJECTIVES: Arterial pressure waveform analysis is a less invasive alternative to the pulmonary artery catheter for continuous cardiac output (CO) measurement. Uncalibrated and calibrated systems are actually available (ie, the FloTrac/Vigileo system [Edwards Lifesciences, Irvine, CA] and the PiCCOplus system [Pulsion Medical Systems, Munich, Germany]). According to the FloTrac/Vigileo manufacturer, reliable measurements can be performed using any existing arterial catheter. The aim of this study was to evaluate CO determined by the FloTrac/Vigileo system using a radial (FCO(radial)) and femoral arterial catheter (FCO(femoral)) as well as the PiCCOplus system (PCO). Intermittent pulmonary artery thermodilution (ICO) was used as primary reference technique.
DESIGN: A prospective clinical study.
SETTING: A teaching hospital, single center. PARTICIPANTS: Twenty-six cardiac surgery patients.
INTERVENTIONS: Perioperative CO measurements.
MEASUREMENTS AND MAIN RESULTS: CO was assessed at predefined measurement points. FCO(radial), FCO(femoral), and PCO were recorded after the induction of anesthesia, after sternotomy, at skin closure, after intensive care unit transfer, and during intensive care unit stay 12 and 24 hours after study initiation. ICO was determined as the mean of 3 bolus injections. Bland-Altman analysis revealed comparable mean bias and limits of agreement for FCO(radial), FCO(femoral), and PCO when compared with ICO. There was a decreased agreement for all devices in the postoperative period. However, a consistently close agreement was observed for the direct comparison between FCO(radial) and FCO(femoral).
CONCLUSIONS: Performance of the FloTrac/Vigileo system via radial as well as femoral access and the PiCCOplus monitoring for cardiac output measurement were comparable when tested against intermittent thermodilution in cardiac surgery patients. Copyright (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19700349     DOI: 10.1053/j.jvca.2009.06.003

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  11 in total

1.  The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study.

Authors:  Yohei Sotomi; Katsuomi Iwakura; Yoshiharu Higuchi; Kazuo Abe; Junko Yoshida; Takafumi Masai; Kenshi Fujii
Journal:  J Clin Monit Comput       Date:  2013-06-08       Impact factor: 2.502

2.  Goal-directed fluid therapy in gastrointestinal surgery in older coronary heart disease patients: randomized trial.

Authors:  Hong Zheng; Hai Guo; Jian-Rong Ye; Lin Chen; Hai-Ping Ma
Journal:  World J Surg       Date:  2013-12       Impact factor: 3.352

Review 3.  [Hemodynamic monitoring in one-lung ventilation].

Authors:  S Haas; R Kiefmann; V Eichhorn; A E Goetz; D A Reuter
Journal:  Anaesthesist       Date:  2009-11       Impact factor: 1.041

Review 4.  Minimally invasive monitoring of cardiac output in the cardiac surgery intensive care unit.

Authors:  Jamal A Alhashemi; Maurizio Cecconi; Giorgio della Rocca; Maxime Cannesson; Christoph K Hofer
Journal:  Curr Heart Fail Rep       Date:  2010-09

5.  Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock.

Authors:  Cornelis Slagt; Marcel A de Leeuw; Jan Beute; Emmy Rijnsburger; Martijn Hoeksema; Jan W R Mulder; Ignacio Malagon; A B Johan Groeneveld
Journal:  J Clin Monit Comput       Date:  2012-11-15       Impact factor: 2.502

Review 6.  Pulse waveform hemodynamic monitoring devices: recent advances and the place in goal-directed therapy in cardiac surgical patients.

Authors:  Adham Hendy; Şerban Bubenek
Journal:  Rom J Anaesth Intensive Care       Date:  2016-04

7.  Pitfalls in haemodynamic monitoring based on the arterial pressure waveform.

Authors:  Luigi Camporota; Richard Beale
Journal:  Crit Care       Date:  2010-03-05       Impact factor: 9.097

8.  Early non-invasive cardiac output monitoring in hemodynamically unstable intensive care patients: a multi-center randomized controlled trial.

Authors:  Jukka Takala; Esko Ruokonen; Jyrki J Tenhunen; Ilkka Parviainen; Stephan M Jakob
Journal:  Crit Care       Date:  2011-06-15       Impact factor: 9.097

9.  The value of arterial pressure waveform cardiac output measurements in the radial and femoral artery in major cardiac surgery patients.

Authors:  A van Drumpt; J van Bommel; S Hoeks; F Grüne; T Wolvetang; J Bekkers; M Ter Horst
Journal:  BMC Anesthesiol       Date:  2017-03-14       Impact factor: 2.217

10.  Comparison the accuracy and trending ability of cardiac index measured by the fourth-generation of FloTrac with the PiCCO device in septic shock patients.

Authors:  Bodin Khwannimit; Rattina Jomsuriya
Journal:  Turk J Med Sci       Date:  2020-04-27       Impact factor: 0.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.