Literature DB >> 19696219

Technical breakthroughs in the wearable artificial kidney (WAK).

Victor Gura1, Alexandra S Macy, Masoud Beizai, Carlos Ezon, Thomas A Golper.   

Abstract

BACKGROUND: The wearable artificial kidney (WAK) has been a holy grail in kidney failure for decades. Described herein are the breakthroughs that made possible the creation of the WAK V1.0 and its advanced versions V 1.1 and 1.2.
DESIGN: The battery-powered WAK pump has a double channel pulsatile counter phase flow. This study clarifies the role of pulsatile blood and dialysate flow, a high-flux membrane with a larger surface area, and the optimization of the dialysate pH. Flows and clearances from the WAK pump were compared with conventional pumps and with gravity steady flow.
RESULTS: Raising dialysate pH to 7.4 increased adsorption of ammonia. Clearances were higher with pulsatile flow as compared with steady flow. The light WAK pump, geometrically suitable for wearability, delivered the same clearances as larger and heavier pumps that cannot be battery operated. Beta(2) microglobulin (beta(2)M) was removed from human blood in vitro. Activated charcoal adsorbed most beta(2)M in the dialysate. The WAK V1.0 delivered an effective creatinine clearance of 18.5 +/- 3.2 ml/min and the WAK V1.1 27.0 +/- 4.0 ml/min in uremic pigs.
CONCLUSIONS: Half-cycle differences between blood and dialysate, alternating transmembrane pressures (TMP), higher amplitude pulsations, and a push-pull flow increased convective transport. This creates a yet undescribed type of hemodiafiltration. Further improvements were achieved with a larger surface area high-flux dialyzer and a higher dialysate pH. The data suggest that the WAK might be an efficient way of providing daily dialysis and optimizing end stage renal disease (ESRD) treatment.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19696219      PMCID: PMC2736696          DOI: 10.2215/CJN.02790409

Source DB:  PubMed          Journal:  Clin J Am Soc Nephrol        ISSN: 1555-9041            Impact factor:   8.237


  25 in total

1.  The case for daily dialysis: its impact on costs and quality of life.

Authors:  P E Mohr; P J Neumann; S J Franco; J Marainen; R Lockridge; G Ting
Journal:  Am J Kidney Dis       Date:  2001-04       Impact factor: 8.860

2.  Is HCFA's reimbursement policy controlling quality of care for end-stage renal disease patients?

Authors:  R S Lockridge; J K McKinney
Journal:  ASAIO J       Date:  2001 Sep-Oct       Impact factor: 2.872

3.  Psychosocial variables, quality of life, and religious beliefs in ESRD patients treated with hemodialysis.

Authors:  Samir S Patel; Viral S Shah; Rolf A Peterson; Paul L Kimmel
Journal:  Am J Kidney Dis       Date:  2002-11       Impact factor: 8.860

Review 4.  Push/pull hemodiafiltration: technical aspects and clinical effectiveness.

Authors:  M Miwa; T Shinzato
Journal:  Artif Organs       Date:  1999-12       Impact factor: 3.094

5.  On-line haemodiafiltration versus low-flux haemodialysis. A prospective randomized study.

Authors:  V Wizemann; C Lotz; F Techert; S Uthoff
Journal:  Nephrol Dial Transplant       Date:  2000       Impact factor: 5.992

6.  Dialysis adequacy and health related quality of life in hemodialysis patients.

Authors:  Braden J Manns; Jeffrey A Johnson; Ken Taub; Garth Mortis; William A Ghali; Cam Donaldson
Journal:  ASAIO J       Date:  2002 Sep-Oct       Impact factor: 2.872

7.  Health-related quality of life as a predictor of mortality and hospitalization: the Dialysis Outcomes and Practice Patterns Study (DOPPS).

Authors:  Donna L Mapes; Antonio Alberto Lopes; Sudtida Satayathum; Keith P McCullough; David A Goodkin; Francesco Locatelli; Shunichi Fukuhara; Eric W Young; Kiyoshi Kurokawa; Akira Saito; Jürgen Bommer; Robert A Wolfe; Philip J Held; Friedrich K Port
Journal:  Kidney Int       Date:  2003-07       Impact factor: 10.612

8.  Beta2-microglobulin and phosphate clearances using a wearable artificial kidney: a pilot study.

Authors:  Victor Gura; Andrew Davenport; Masoud Beizai; Carlos Ezon; Claudio Ronco
Journal:  Am J Kidney Dis       Date:  2009-04-19       Impact factor: 8.860

9.  A wearable haemodialysis device for patients with end-stage renal failure: a pilot study.

Authors:  Andrew Davenport; Victor Gura; Claudio Ronco; Masoud Beizai; Carlos Ezon; Edmond Rambod
Journal:  Lancet       Date:  2007-12-15       Impact factor: 79.321

10.  A wearable hemofilter for continuous ambulatory ultrafiltration.

Authors:  V Gura; C Ronco; F Nalesso; A Brendolan; M Beizai; C Ezon; A Davenport; E Rambod
Journal:  Kidney Int       Date:  2007-12-05       Impact factor: 10.612

View more
  21 in total

1.  Rapid fluid removal during dialysis is associated with cardiovascular morbidity and mortality.

Authors:  Jennifer E Flythe; Stephen E Kimmel; Steven M Brunelli
Journal:  Kidney Int       Date:  2010-10-06       Impact factor: 10.612

2.  A wearable artificial kidney for patients with end-stage renal disease.

Authors:  Victor Gura; Matthew B Rivara; Scott Bieber; Raj Munshi; Nancy Colobong Smith; Lori Linke; John Kundzins; Masoud Beizai; Carlos Ezon; Larry Kessler; Jonathan Himmelfarb
Journal:  JCI Insight       Date:  2016-06-02

Review 3.  Renal replacement therapy review: past, present and future.

Authors:  Geoffrey M Fleming
Journal:  Organogenesis       Date:  2011-01-01       Impact factor: 2.500

Review 4.  Microelectromechanical systems and nephrology: the next frontier in renal replacement technology.

Authors:  Steven Kim; Shuvo Roy
Journal:  Adv Chronic Kidney Dis       Date:  2013-11       Impact factor: 3.620

Review 5.  Repopulation of decellularized whole organ scaffold using stem cells: an emerging technology for the development of neo-organ.

Authors:  Aleem Ahmed Khan; Sandeep Kumar Vishwakarma; Avinash Bardia; J Venkateshwarulu
Journal:  J Artif Organs       Date:  2014-07-17       Impact factor: 1.731

6.  The Wearable Artificial Kidney.

Authors:  George M Dolson
Journal:  Methodist Debakey Cardiovasc J       Date:  2020 Oct-Dec

7.  Protein Separation and Hemocompatibility of Nitride Membranes in Microfluidic Filtration Systems.

Authors:  Alec Salminen; Kayli Hill; L Henry Chung; L James McGrath; Dean G Johnson
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2018-07

8.  Patient-stated preferences regarding volume-related risk mitigation strategies for hemodialysis.

Authors:  Jennifer E Flythe; Thomas W Mangione; Steven M Brunelli; Gary C Curhan
Journal:  Clin J Am Soc Nephrol       Date:  2014-06-05       Impact factor: 8.237

9.  An experimental and numerical study of the flow and mass transfer in a model of the wearable artificial kidney dialyzer.

Authors:  Edmond Rambod; Masoud Beizai; Moshe Rosenfeld
Journal:  Biomed Eng Online       Date:  2010-05-24       Impact factor: 2.819

10.  Second Generation Nanoporous Silicon Nitride Membranes for High Toxin Clearance and Small Format Hemodialysis.

Authors:  Kayli Hill; Samuel N Walker; Alec Salminen; Hung L Chung; Xunzhi Li; Bahie Ezzat; Joshua J Miller; Jon-Paul S DesOrmeaux; Jingkai Zhang; Andrew Hayden; Tucker Burgin; Lindsay Piraino; Marina N May; Thomas R Gaborski; James A Roussie; Jeremy Taylor; Louis DiVincenti; Alexander A Shestopalov; James L McGrath; Dean G Johnson
Journal:  Adv Healthc Mater       Date:  2020-01-15       Impact factor: 9.933

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.