A wearable hemofilter for continuous ambulatory ultrafiltration.

V Gura1, C Ronco, F Nalesso, A Brendolan, M Beizai, C Ezon, A Davenport, E Rambod.   

Abstract

Ultrafiltration is effective for treating fluid overload, but there are no suitable machines for ambulatory treatment. This study summarizes the use of a light-weight wearable continuous ambulatory ultrafiltration device consisting of a hollow fiber hemofilter, a battery operated pulsatile pump, and two micropumps to control heparin administration and ultrafiltration. Six volume-overloaded patients underwent ultrafiltration for 6 h with treatment discontinued in one patient due to a clotted catheter. Blood flow averaged 116 ml min(-1), the ultrafiltration rate ranged from 120-288 ml h(-1) with about 150 mmol of sodium removed. Blood pressure, pulse, and biochemical parameters remained stable with no significant hemolysis or complications. Our data show that the wearable hemofilter appears to be safe, effective, and practical for patients. This device could have a major impact on the quality of life of fluid-overloaded patients with heart failure. Additional studies will be needed to confirm these initial promising results.

Entities:  

Mesh:

Year:  2007        PMID: 18059456     DOI: 10.1038/sj.ki.5002711

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  14 in total

1.  A wearable artificial kidney for patients with end-stage renal disease.

Authors:  Victor Gura; Matthew B Rivara; Scott Bieber; Raj Munshi; Nancy Colobong Smith; Lori Linke; John Kundzins; Masoud Beizai; Carlos Ezon; Larry Kessler; Jonathan Himmelfarb
Journal:  JCI Insight       Date:  2016-06-02

Review 2.  Microelectromechanical systems and nephrology: the next frontier in renal replacement technology.

Authors:  Steven Kim; Shuvo Roy
Journal:  Adv Chronic Kidney Dis       Date:  2013-11       Impact factor: 3.620

Review 3.  Home haemodialysis and uraemic toxin removal: does a happy marriage exist?

Authors:  Raymond Vanholder; Sunny Eloot; Nathalie Neirynck; Wim Van Biesen
Journal:  Nat Rev Nephrol       Date:  2012-08-28       Impact factor: 28.314

4.  Dialysis: A wearable dialysis device: the first step to continuous therapy.

Authors:  Andrew Davenport
Journal:  Nat Rev Nephrol       Date:  2016-07-11       Impact factor: 28.314

Review 5.  Ambulatory Hemodialysis-Technology Landscape and Potential for Patient-Centered Treatment.

Authors:  Nina Hojs; William H Fissell; Shuvo Roy
Journal:  Clin J Am Soc Nephrol       Date:  2019-11-14       Impact factor: 8.237

6.  Bioartificial Renal Epithelial Cell System (BRECS): A Compact, Cryopreservable Extracorporeal Renal Replacement Device.

Authors:  Deborah A Buffington; Christopher J Pino; Lijun Chen; Angela J Westover; Gretchen Hageman; H David Humes
Journal:  Cell Med       Date:  2012-01

7.  Technical breakthroughs in the wearable artificial kidney (WAK).

Authors:  Victor Gura; Alexandra S Macy; Masoud Beizai; Carlos Ezon; Thomas A Golper
Journal:  Clin J Am Soc Nephrol       Date:  2009-08-20       Impact factor: 8.237

8.  Achievements and challenges in bioartificial kidney development.

Authors:  Farah Tasnim; Rensheng Deng; Min Hu; Sean Liour; Yao Li; Ming Ni; Jackie Y Ying; Daniele Zink
Journal:  Fibrogenesis Tissue Repair       Date:  2010-08-10

Review 9.  Portable and wearable dialysis devices for the treatment of patients with end-stage kidney failure: Wishful thinking or just over the horizon?

Authors:  Andrew Davenport
Journal:  Pediatr Nephrol       Date:  2014-10-21       Impact factor: 3.714

10.  Uraemic toxins and new methods to control their accumulation: game changers for the concept of dialysis adequacy.

Authors:  Griet Glorieux; James Tattersall
Journal:  Clin Kidney J       Date:  2015-06-01
View more