Reduction of the estimated radiation dose and associated patient risk with prospective ECG-gated 256-slice CT coronary angiography.

E P Efstathopoulos1, N L Kelekis, I Pantos, E Brountzos, S Argentos, J Grebác, D Ziaka, D G Katritsis, I Seimenis.   

Abstract

Computed tomography (CT) coronary angiography has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but high radiation doses have been reported. Prospective ECG-gating using a 'step-and-shoot' axial scanning protocol has been shown to reduce radiation exposure effectively while maintaining diagnostic accuracy. 256-slice scanners with 80 mm detector coverage have been currently introduced into practice, but their impact on radiation exposure has not been adequately studied. The aim of this study was to assess radiation doses associated with CT coronary angiography using a 256-slice CT scanner. Radiation doses were estimated for 25 patients scanned with either prospective or retrospective ECG-gating. Image quality was assessed objectively in terms of mean CT attenuation at selected regions of interest on axial coronary images and subjectively by coronary segment quality scoring. It was found that radiation doses associated with prospective ECG-gating were significantly lower than retrospective ECG-gating (3.2 +/- 0.6 mSv versus 13.4 +/- 2.7 mSv). Consequently, the radiogenic fatal cancer risk for the patient is much lower with prospective gating (0.0176% versus 0.0737%). No statistically significant differences in image quality were observed between the two scanning protocols for both objective and subjective quality assessments. Therefore, prospective ECG-gating using a 'step-and-shoot' protocol that covers the cardiac anatomy in two axial acquisitions effectively reduces radiation doses in 256-slice CT coronary angiography without compromising image quality.

Entities:  

Mesh:

Year:  2009        PMID: 19671974     DOI: 10.1088/0031-9155/54/17/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

Review 1.  Low dose CT of the heart: a quantum leap into a new era of cardiovascular imaging.

Authors:  E Maffei; C Martini; S De Crescenzo; T Arcadi; A Clemente; E Capuano; A Rossi; R Malagò; N Mollet; A Weustink; C Tedeschi; L La Grutta; S Seitun; A Igoren Guaricci; F Cademartiri
Journal:  Radiol Med       Date:  2010-06-23       Impact factor: 3.469

Review 2.  Beta-blocker administration protocol for prospectively ECG-triggered coronary CT angiography.

Authors:  Akmal Sabarudin; Zhonghua Sun
Journal:  World J Cardiol       Date:  2013-12-26

Review 3.  SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT.

Authors:  Sandra S Halliburton; Suhny Abbara; Marcus Y Chen; Ralph Gentry; Mahadevappa Mahesh; Gilbert L Raff; Leslee J Shaw; Jörg Hausleiter
Journal:  J Cardiovasc Comput Tomogr       Date:  2011 Jul-Aug

4.  Low-dose coronary-CT angiography using step and shoot at any heart rate: comparison of image quality at systole for high heart rate and diastole for low heart rate with a 128-slice dual-source machine.

Authors:  Jean-François Paul; Aude Amato; Adela Rohnean
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-24       Impact factor: 2.357

5.  Comparison of radiation dose and image quality: 320-MDCT versus 64-MDCT coronary angiography.

Authors:  Atif Khan; Faisal Khosa; Khurram Nasir; Aya Yassin; Melvin E Clouse
Journal:  AJR Am J Roentgenol       Date:  2011-07       Impact factor: 3.959

6.  Effect of heart rate on the diagnostic accuracy of 256-slice computed tomography angiography in the detection of coronary artery stenosis: ROC curve analysis.

Authors:  Gang Wang; Yifen Wu; Zhentao Zhang; Xiaolin Zheng; Yulan Zhang; Manqiu Liang; Huanchu Yuan; Haiping Shen; Dewei Li
Journal:  Exp Ther Med       Date:  2016-03-11       Impact factor: 2.447

7.  Effect of Tube Voltage (100 vs. 120 kVp) on Radiation Dose and Image Quality using Prospective Gating 320 Row Multi-detector Computed Tomography Angiography.

Authors:  Atif N Khan; Faisal Khosa; Waqas Shuaib; Khurram Nasir; Ron Blankstein; Melvin Clouse
Journal:  J Clin Imaging Sci       Date:  2013-12-31

8.  Low-dose coronary computed tomography angiography using prospective ECG-triggering compared to invasive coronary angiography.

Authors:  Yoo Jin Hong; Sang Jin Kim; Sang Min Lee; Phil Ki Min; Young Won Yoon; Byung Kwon Lee; Tae Hoon Kim
Journal:  Int J Cardiovasc Imaging       Date:  2010-08-01       Impact factor: 2.357

Review 9.  Coronary imaging techniques with emphasis on CT and MRI.

Authors:  Mathieu Lederlin; Jean-Benoit Thambo; Valérie Latrabe; Olivier Corneloup; Hubert Cochet; Michel Montaudon; François Laurent
Journal:  Pediatr Radiol       Date:  2011-11-30

10.  Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality.

Authors:  D Muenzel; P B Noel; F Dorn; M Dobritz; E J Rummeny; A Huber
Journal:  Eur Radiol       Date:  2011-06-28       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.