Optimal linear combinations of array elements for B1 mapping.

Shaihan J Malik1, David J Larkman, Joseph V Hajnal.   

Abstract

Accuracy of B(1) mapping for array coils can be improved by mapping the fields produced by driving linear combinations of the array elements, chosen to produce a more uniform distribution of B(1) amplitude. Quality of the resulting single element B(1) maps is influenced by the transformation used both via the uniformity of the resulting linear combination fields and by the degree to which these linear combinations differ from one another. In this work we investigate the effect of using different transformations on the quality of B(1) maps by simulating the B(1) mapping process for two different techniques, using real data from a 3T 8-channel body transmit system. Different transformations are generated using a single complex parameter. It is demonstrated that the optimal transformation within this framework is different for different imaging targets (pelvis and brain of healthy volunteers, and water and oil phantoms). For the same target (pelvis) the optimum condition, however, is similar for a number of subjects, suggesting that optimal configurations to be used for calibrating coils in specific anatomical contexts can be determined in advance. Potential gains may be translated into significant reductions in scan time for equivalent signal-to-noise ratio coil maps. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19658161     DOI: 10.1002/mrm.22068

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Regularized estimation of magnitude and phase of multi-coil b1 field via Bloch-Siegert B1 mapping and coil combination optimizations.

Authors:  Feng Zhao; Jeffrey A Fessler; Steven M Wright; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2014-06-09       Impact factor: 10.048

2.  An in vivo comparison of the DREAM sequence with current RF shim technology.

Authors:  Kay Nehrke; Alois M Sprinkart; Peter Börnert
Journal:  MAGMA       Date:  2014-08-10       Impact factor: 2.310

Review 3.  Towards accurate and precise T 1 and extracellular volume mapping in the myocardium: a guide to current pitfalls and their solutions.

Authors:  Donnie Cameron; Vassilios S Vassiliou; David M Higgins; Peter D Gatehouse
Journal:  MAGMA       Date:  2017-06-12       Impact factor: 2.310

4.  Performance of external and internal coil configurations for prostate investigations at 7 T.

Authors:  Gregory J Metzger; Pierre-Francois van de Moortele; Can Akgun; Carl J Snyder; Steen Moeller; John Strupp; Peter Andersen; Devashish Shrivastava; Tommy Vaughan; Kamil Ugurbil; Gregor Adriany
Journal:  Magn Reson Med       Date:  2010-08-25       Impact factor: 4.668

Review 5.  Parallel transmission for ultrahigh-field imaging.

Authors:  Francesco Padormo; Arian Beqiri; Joseph V Hajnal; Shaihan J Malik
Journal:  NMR Biomed       Date:  2015-05-19       Impact factor: 4.044

6.  Impact of number of channels on RF shimming at 3T.

Authors:  Alexander S Childs; Shaihan J Malik; Declan P O'Regan; Joseph V Hajnal
Journal:  MAGMA       Date:  2013-01-13       Impact factor: 2.310

7.  Phase relaxed localized excitation pulses for inner volume fast spin echo imaging.

Authors:  Shaihan J Malik; Joseph V Hajnal
Journal:  Magn Reson Med       Date:  2015-10-09       Impact factor: 4.668

8.  Large dynamic range relative B1+ mapping.

Authors:  Francesco Padormo; Aaron T Hess; Paul Aljabar; Shaihan J Malik; Peter Jezzard; Matthew D Robson; Joseph V Hajnal; Peter J Koopmans
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.