Literature DB >> 28608328

Towards accurate and precise T 1 and extracellular volume mapping in the myocardium: a guide to current pitfalls and their solutions.

Donnie Cameron1, Vassilios S Vassiliou2,3, David M Higgins4, Peter D Gatehouse3.   

Abstract

Mapping of the longitudinal relaxation time (T 1) and extracellular volume (ECV) offers a means of identifying pathological changes in myocardial tissue, including diffuse changes that may be invisible to existing T 1-weighted methods. This technique has recently shown strong clinical utility for pathologies such as Anderson-Fabry disease and amyloidosis and has generated clinical interest as a possible means of detecting small changes in diffuse fibrosis; however, scatter in T 1 and ECV estimates offers challenges for detecting these changes, and bias limits comparisons between sites and vendors. There are several technical and physiological pitfalls that influence the accuracy (bias) and precision (repeatability) of T 1 and ECV mapping methods. The goal of this review is to describe the most significant of these, and detail current solutions, in order to aid scientists and clinicians to maximise the utility of T 1 mapping in their clinical or research setting. A detailed summary of technical and physiological factors, issues relating to contrast agents, and specific disease-related issues is provided, along with some considerations on the future directions of the field.

Entities:  

Keywords:  Accuracy; Cardiovascular magnetic resonance; Extracellular volume; Precision; T 1 mapping

Mesh:

Substances:

Year:  2017        PMID: 28608328      PMCID: PMC5813078          DOI: 10.1007/s10334-017-0631-2

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  139 in total

1.  Field mapping without reference scan using asymmetric echo-planar techniques.

Authors:  R Gruetter; I Tkác
Journal:  Magn Reson Med       Date:  2000-02       Impact factor: 4.668

2.  Cardiac susceptibility artifacts arising from the heart-lung interface.

Authors:  M K Atalay; B P Poncelet; H L Kantor; T J Brady; R M Weisskoff
Journal:  Magn Reson Med       Date:  2001-02       Impact factor: 4.668

3.  Single-breathhold 3D-trueFISP cine cardiac imaging.

Authors:  Bernd A Jung; Jürgen Hennig; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2002-11       Impact factor: 4.668

4.  Reduction of transient signal oscillations in true-FISP using a linear flip angle series magnetization preparation.

Authors:  Vibhas S Deshpande; Yiu-Cho Chung; Qiang Zhang; Steven M Shea; Debiao Li
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

Review 5.  Molecular mechanisms of amyloidosis.

Authors:  Giampaolo Merlini; Vittorio Bellotti
Journal:  N Engl J Med       Date:  2003-08-07       Impact factor: 91.245

6.  Cardiac SSFP imaging at 3 Tesla.

Authors:  Michael Schär; Sebastian Kozerke; Stefan E Fischer; Peter Boesiger
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

7.  Measurement of the gadopentetate dimeglumine partition coefficient in human myocardium in vivo: normal distribution and elevation in acute and chronic infarction.

Authors:  S J Flacke; S E Fischer; C H Lorenz
Journal:  Radiology       Date:  2001-03       Impact factor: 11.105

8.  Measurement of the distribution volume of gadopentetate dimeglumine at echo-planar MR imaging to quantify myocardial infarction: comparison with 99mTc-DTPA autoradiography in rats.

Authors:  H Arheden; M Saeed; C B Higgins; D W Gao; J Bremerich; R Wyttenbach; M W Dae; M F Wendland
Journal:  Radiology       Date:  1999-06       Impact factor: 11.105

9.  Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart.

Authors:  Daniel R Messroghli; Aleksandra Radjenovic; Sebastian Kozerke; David M Higgins; Mohan U Sivananthan; John P Ridgway
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

Review 10.  Neuroradiologic differential diagnosis of cerebral intraparenchymal hemorrhage.

Authors:  N Anzalone; R Scotti; R Riva
Journal:  Neurol Sci       Date:  2004-03       Impact factor: 3.307

View more
  7 in total

1.  Advances in cardiovascular MR imaging.

Authors:  Tim Leiner; Gustav Strijkers
Journal:  MAGMA       Date:  2018-02       Impact factor: 2.310

2.  Value of native T1 mapping in the prediction of major adverse cardiovascular events in hemodialysis patients.

Authors:  Le Qin; Shengjia Gu; Ruijie Xiao; Peng Liu; Fuhua Yan; Haijin Yu; Wenjie Yang
Journal:  Eur Radiol       Date:  2022-05-12       Impact factor: 7.034

3.  Temporally resolved parametric assessment of Z-magnetization recovery (TOPAZ): Dynamic myocardial T1 mapping using a cine steady-state look-locker approach.

Authors:  Sebastian Weingärtner; Chetan Shenoy; Benedikt Rieger; Lothar R Schad; Jeanette Schulz-Menger; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2017-08-30       Impact factor: 4.668

4.  Magnetic resonance imaging: Physics basics for the cardiologist.

Authors:  Vassilios S Vassiliou; Donnie Cameron; Sanjay K Prasad; Peter D Gatehouse
Journal:  JRSM Cardiovasc Dis       Date:  2018-05-22

5.  Aortic stiffness is independently associated with interstitial myocardial fibrosis by native T1 and accelerated in the presence of chronic kidney disease.

Authors:  Mengzhen Chen; Luca Arcari; Juergen Engel; Tilo Freiwald; Steffen Platschek; Hui Zhou; Hafisyatul Zainal; Stefan Buettner; Andreas M Zeiher; Helmut Geiger; Ingeborg Hauser; Eike Nagel; Valentina O Puntmann
Journal:  Int J Cardiol Heart Vasc       Date:  2019-06-26

6.  Fast calculation software for modified Look-Locker inversion recovery (MOLLI) T1 mapping.

Authors:  Yoon-Chul Kim; Khu Rai Kim; Hyelee Lee; Yeon Hyeon Choe
Journal:  BMC Med Imaging       Date:  2021-02-12       Impact factor: 1.930

7.  Fast myocardial T mapping in mice using k-space weighted image contrast and a Bloch simulation-optimized radial sampling pattern.

Authors:  Maximilian Gram; Daniel Gensler; Patrick Winter; Michael Seethaler; Paula Anahi Arias-Loza; Johannes Oberberger; Peter Michael Jakob; Peter Nordbeck
Journal:  MAGMA       Date:  2021-09-07       Impact factor: 2.310

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.