Literature DB >> 24957945

Measuring myofiber orientations from high-frequency ultrasound images using multiscale decompositions.

Xulei Qin1, Baowei Fei.   

Abstract

High-frequency ultrasound (HFU) has the ability to image both skeletal and cardiac muscles. The quantitative assessment of these myofiber orientations has a number of applications in both research and clinical examinations; however, difficulties arise due to the severe speckle noise contained in the HFU images. Thus, for the purpose of automatically measuring myofiber orientations from two-dimensional HFU images, we propose a two-step multiscale image decomposition method. It combines a nonlinear anisotropic diffusion filter and a coherence enhancing diffusion filter to extract myofibers. This method has been verified by ultrasound data from simulated phantoms, excised fiber phantoms, specimens of porcine hearts, and human skeletal muscles in vivo. The quantitative evaluations of both phantoms indicated that the myofiber measurements of our proposed method were more accurate than other methods. The myofiber orientations extracted from different layers of the porcine hearts matched the prediction of an established cardiac mode and demonstrated the feasibility of extracting cardiac myofiber orientations from HFU images ex vivo. Moreover, HFU also demonstrated the ability to measure myofiber orientations in vivo.

Entities:  

Mesh:

Year:  2014        PMID: 24957945      PMCID: PMC4137038          DOI: 10.1088/0031-9155/59/14/3907

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  43 in total

1.  Measurement of muscle contraction with ultrasound imaging.

Authors:  P W Hodges; L H M Pengel; R D Herbert; S C Gandevia
Journal:  Muscle Nerve       Date:  2003-06       Impact factor: 3.217

2.  Heart wall myofibers are arranged in minimal surfaces to optimize organ function.

Authors:  Peter Savadjiev; Gustav J Strijkers; Adrianus J Bakermans; Emmanuel Piuze; Steven W Zucker; Kaleem Siddiqi
Journal:  Proc Natl Acad Sci U S A       Date:  2012-05-29       Impact factor: 11.205

3.  3D ultrasound image segmentation using wavelet support vector machines.

Authors:  Hamed Akbari; Baowei Fei
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

4.  Nonlinear anisotropic filtering of MRI data.

Authors:  G Gerig; O Kubler; R Kikinis; F A Jolesz
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

5.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

6.  Improving reliability and accuracy of vibration parameters of vocal folds based on high-speed video and electroglottography.

Authors:  Xulei Qin; Supin Wang; Mingxi Wan
Journal:  IEEE Trans Biomed Eng       Date:  2009-03-04       Impact factor: 4.538

7.  A new 15-50 MHz array-based micro-ultrasound scanner for preclinical imaging.

Authors:  F Stuart Foster; James Mehi; Marc Lukacs; Desmond Hirson; Chris White; Chris Chaggares; Andrew Needles
Journal:  Ultrasound Med Biol       Date:  2009-08-03       Impact factor: 2.998

8.  Estimation of muscle fiber orientation in ultrasound images using revoting hough transform (RVHT).

Authors:  Yongjin Zhou; Yong-Ping Zheng
Journal:  Ultrasound Med Biol       Date:  2008-04-16       Impact factor: 2.998

9.  Measuring body-cover vibration of vocal folds based on high frame rate ultrasonic imaging and high-speed video.

Authors:  Xulei Qin; Liang Wu; Hujie Jiang; Shanshan Tang; Supin Wang; Mingxi Wan
Journal:  IEEE Trans Biomed Eng       Date:  2011-05-19       Impact factor: 4.538

10.  A comparison of the imaging performance of high resolution ultrasound scanners for preclinical imaging.

Authors:  Carmel M Moran; Stephen D Pye; William Ellis; Anna Janeczko; Keith D Morris; Alan S McNeilly; Hamish M Fraser
Journal:  Ultrasound Med Biol       Date:  2011-01-21       Impact factor: 2.998

View more
  11 in total

1.  Simulating cardiac ultrasound image based on MR diffusion tensor imaging.

Authors:  Xulei Qin; Silun Wang; Ming Shen; Guolan Lu; Xiaodong Zhang; Mary B Wagner; Baowei Fei
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

2.  DTI template-based estimation of cardiac fiber orientations from 3D ultrasound.

Authors:  Xulei Qin; Baowei Fei
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

3.  Spectral-spatial classification for noninvasive cancer detection using hyperspectral imaging.

Authors:  Guolan Lu; Luma Halig; Dongsheng Wang; Xulei Qin; Zhuo Georgia Chen; Baowei Fei
Journal:  J Biomed Opt       Date:  2014       Impact factor: 3.170

4.  Imaging technologies for cardiac fiber and heart failure: a review.

Authors:  Shana R Watson; James D Dormer; Baowei Fei
Journal:  Heart Fail Rev       Date:  2018-03       Impact factor: 4.214

5.  Register cardiac fiber orientations from 3D DTI volume to 2D ultrasound image of rat hearts.

Authors:  Xulei Qin; Silun Wang; Ming Shen; Xiaodong Zhang; Stamatios Lerakis; Mary B Wagner; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

6.  Determining Cardiac Fiber Orientation Using FSL and Registered Ultrasound/DTI volumes.

Authors:  James Dormer; Xulei Qin; Ming Shen; Silun Wang; Xiaodong Zhang; Rong Jiang; Mary B Wagner; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-04-01

7.  3D in vivo imaging of rat hearts by high frequency ultrasound and its application in myofiber orientation wrapping.

Authors:  Xulei Qin; Silun Wang; Ming Shen; Xiaodong Zhang; Stamatios Lerakis; Mary B Wagner; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015

8.  Quantitative Wavelength Analysis and Image Classification for Intraoperative Cancer Diagnosis with Hyperspectral Imaging.

Authors:  Guolan Lu; Xulei Qin; Dongsheng Wang; Zhuo Georgia Chen; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

9.  Estimating cardiac fiber orientations in pig hearts using registered ultrasound and MR image volumes.

Authors:  James D Dormer; Yuguang Meng; Xiaodong Zhang; Rong Jiang; Mary B Wagner; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-15

10.  Automated classification of optical coherence tomography images of human atrial tissue.

Authors:  Yu Gan; David Tsay; Syed B Amir; Charles C Marboe; Christine P Hendon
Journal:  J Biomed Opt       Date:  2016-10       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.