Literature DB >> 19641236

MREIT with SENSE acceleration using a dedicated RF coil design.

L Tugan Muftuler1, Gang Chen, Mark J Hamamura, Seung Hoon Ha.   

Abstract

We have adapted a SENSE-accelerated imaging technique to magnetic resonance electrical impedance tomography (MREIT) in order to acquire data faster or improve spatial resolution without increasing the data acquisition time. We also designed and optimized an eight-channel, dedicated phased array coil for this application. The RF coil was designed as two planar arrays so that the open sides could accommodate the MREIT electrodes. A quasi-intrinsic decoupling scheme was used to minimize couplings between coil elements, and a restricted geometry optimization was applied to achieve high and uniform SNR within a given coil geometry and animal size. The impact of variability in the size of animals was also investigated in the optimization. This coil geometry provided approximately three times higher SNR at the center of a phantom when compared to a transmit/receive birdcage coil designed for MREIT of small animals. Therefore, the SNR was superior to the data acquired with volume coils even with three times SENSE acceleration. Both magnitude images and MREIT data were acquired from phantoms with and without SENSE acceleration, and the results were compared. The phantom studies demonstrated that conductivity maps can be reconstructed from MREIT data acquired with three times SENSE acceleration and that no discernible artifacts were observed when accelerated data acquisition was compared to non-accelerated data.

Entities:  

Mesh:

Year:  2009        PMID: 19641236      PMCID: PMC2850079          DOI: 10.1088/0967-3334/30/9/004

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  28 in total

1.  Classification of breast tissue by electrical impedance spectroscopy.

Authors:  J E da Silva; J P de Sá; J Jossinet
Journal:  Med Biol Eng Comput       Date:  2000-01       Impact factor: 2.602

2.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  Specific coil design for SENSE: a six-element cardiac array.

Authors:  M Weiger; K P Pruessmann; C Leussler; P Röschmann; P Boesiger
Journal:  Magn Reson Med       Date:  2001-03       Impact factor: 4.668

4.  Experimental results for 2D magnetic resonance electrical impedance tomography (MR-EIT) using magnetic flux density in one direction.

Authors:  Ozlem Birgül; B Murat Eyüboğlu; Y Ziya Ider
Journal:  Phys Med Biol       Date:  2003-11-07       Impact factor: 3.609

5.  Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging.

Authors:  Jacco A de Zwart; Patrick J Ledden; Peter Kellman; Peter van Gelderen; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

6.  Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm.

Authors:  Ohin Kwon; Eung Je Woo; Jeong-Rock Yoon; Jin Keun Seo
Journal:  IEEE Trans Biomed Eng       Date:  2002-02       Impact factor: 4.538

7.  Current constrained voltage scaled reconstruction (CCVSR) algorithm for MR-EIT and its performance with different probing current patterns.

Authors:  Ozlem Birgül; B Murat Eyüboğlu; Y Ziya Ider
Journal:  Phys Med Biol       Date:  2003-03-07       Impact factor: 3.609

8.  Reconstruction of conductivity and current density images using only one component of magnetic field measurements.

Authors:  Jin Keun Seo; Jeong-Rock Yoon; Eung Je Woo; Ohin Kwon
Journal:  IEEE Trans Biomed Eng       Date:  2003-09       Impact factor: 4.538

9.  A 3D electrical impedance tomography (EIT) system for breast cancer detection.

Authors:  V Cherepenin; A Karpov; A Korjenevsky; V Kornienko; A Mazaletskaya; D Mazourov; D Meister
Journal:  Physiol Meas       Date:  2001-02       Impact factor: 2.833

10.  Measurement of thoracic current flow in pigs for the study of defibrillation and cardioversion.

Authors:  Richard S Yoon; Tim P DeMonte; Karshi F Hasanov; Dawn B Jorgenson; Michael L G Joy
Journal:  IEEE Trans Biomed Eng       Date:  2003-10       Impact factor: 4.538

View more
  5 in total

1.  MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic B(Z).

Authors:  V E Arpinar; M J Hamamura; E Degirmenci; L T Muftuler
Journal:  Phys Med Biol       Date:  2012-06-08       Impact factor: 3.609

2.  Imaging of current flow in the human head during transcranial electrical therapy.

Authors:  A K Kasinadhuni; A Indahlastari; M Chauhan; Michael Schär; T H Mareci; R J Sadleir
Journal:  Brain Stimul       Date:  2017-04-20       Impact factor: 8.955

3.  Current density imaging using directly measured harmonic Bz data in MREIT.

Authors:  Chunjae Park; Oh In Kwon
Journal:  Comput Math Methods Med       Date:  2013-03-20       Impact factor: 2.238

4.  Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions.

Authors:  Munish Chauhan; Woo Chul Jeong; Hyung Joong Kim; Oh In Kwon; Eung Je Woo
Journal:  Biomed Eng Online       Date:  2013-08-27       Impact factor: 2.819

5.  Conductivity image enhancement in MREIT using adaptively weighted spatial averaging filter.

Authors:  Tong In Oh; Hyung Joong Kim; Woo Chul Jeong; Hun Wi; Oh In Kwon; Eung Je Woo
Journal:  Biomed Eng Online       Date:  2014-06-26       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.