Literature DB >> 14653558

Experimental results for 2D magnetic resonance electrical impedance tomography (MR-EIT) using magnetic flux density in one direction.

Ozlem Birgül1, B Murat Eyüboğlu, Y Ziya Ider.   

Abstract

Magnetic resonance electrical impedance tomography (MR-EIT) is an emerging imaging technique that reconstructs conductivity images using magnetic flux density measurements acquired employing MRI together with conventional EIT measurements. In this study, experimental MR-EIT images from phantoms with conducting and insulator objects are presented. The technique is implemented using the 0.15 T Middle East Technical University MRI system. The dc current method used in magnetic resonance current density imaging is adopted. A reconstruction algorithm based on the sensitivity matrix relation between conductivity and only one component of magnetic flux distribution is used. Therefore, the requirement for object rotation is eliminated. Once the relative conductivity distribution is found, it is scaled using the peripheral voltage measurements to obtain the absolute conductivity distribution. Images of several insulator and conductor objects in saline filled phantoms are reconstructed. The L2 norm of relative error in conductivity values is found to be 13%, 17% and 14% for three different conductivity distributions.

Entities:  

Mesh:

Year:  2003        PMID: 14653558     DOI: 10.1088/0031-9155/48/21/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  A new magnetic resonance electrical impedance tomography (MREIT) algorithm: the RSM-MREIT algorithm with applications to estimation of human head conductivity.

Authors:  Nuo Gao; S A Zhu; Bin He
Journal:  Phys Med Biol       Date:  2006-05-31       Impact factor: 3.609

2.  Fast imaging for magnetic resonance electrical impedance tomography.

Authors:  Mark J Hamamura; L Tugan Muftuler
Journal:  Magn Reson Imaging       Date:  2008-05-21       Impact factor: 2.546

3.  MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic B(Z).

Authors:  V E Arpinar; M J Hamamura; E Degirmenci; L T Muftuler
Journal:  Phys Med Biol       Date:  2012-06-08       Impact factor: 3.609

4.  MREIT with SENSE acceleration using a dedicated RF coil design.

Authors:  L Tugan Muftuler; Gang Chen; Mark J Hamamura; Seung Hoon Ha
Journal:  Physiol Meas       Date:  2009-07-30       Impact factor: 2.833

5.  A feasibility study of magnetic resonance electrical impedance tomography for prostate cancer detection.

Authors:  Yang Liu; Yingchun Zhang
Journal:  Physiol Meas       Date:  2014-03-12       Impact factor: 2.833

6.  A Post-Processing Method for Three-Dimensional Electrical Impedance Tomography.

Authors:  Sébastien Martin; Charles T M Choi
Journal:  Sci Rep       Date:  2017-08-03       Impact factor: 4.379

7.  Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

Authors:  José P Marques; Daniel K Sodickson; Ozlem Ipek; Christopher M Collins; Rolf Gruetter
Journal:  Magn Reson Med       Date:  2014-08-05       Impact factor: 4.668

8.  Numerical simulations of MREIT conductivity imaging for brain tumor detection.

Authors:  Zi Jun Meng; Saurav Z K Sajib; Munish Chauhan; Rosalind J Sadleir; Hyung Joong Kim; Oh In Kwon; Eung Je Woo
Journal:  Comput Math Methods Med       Date:  2013-04-29       Impact factor: 2.238

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.