Literature DB >> 12696801

Current constrained voltage scaled reconstruction (CCVSR) algorithm for MR-EIT and its performance with different probing current patterns.

Ozlem Birgül1, B Murat Eyüboğlu, Y Ziya Ider.   

Abstract

Conventional injected-current electrical impedance tomography (EIT) and magnetic resonance imaging (MRI) techniques can be combined to reconstruct high resolution true conductivity images. The magnetic flux density distribution generated by the internal current density distribution is extracted from MR phase images. This information is used to form a fine detailed conductivity image using an Ohm's law based update equation. The reconstructed conductivity image is assumed to differ from the true image by a scale factor. EIT surface potential measurements are then used to scale the reconstructed image in order to find the true conductivity values. This process is iterated until a stopping criterion is met. Several simulations are carried out for opposite and cosine current injection patterns to select the best current injection pattern for a 2D thorax model. The contrast resolution and accuracy of the proposed algorithm are also studied. In all simulation studies, realistic noise models for voltage and magnetic flux density measurements are used. It is shown that, in contrast to the conventional EIT techniques, the proposed method has the capability of reconstructing conductivity images with uniform and high spatial resolution. The spatial resolution is limited by the larger element size of the finite element mesh and twice the magnetic resonance image pixel size.

Mesh:

Year:  2003        PMID: 12696801     DOI: 10.1088/0031-9155/48/5/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  A new magnetic resonance electrical impedance tomography (MREIT) algorithm: the RSM-MREIT algorithm with applications to estimation of human head conductivity.

Authors:  Nuo Gao; S A Zhu; Bin He
Journal:  Phys Med Biol       Date:  2006-05-31       Impact factor: 3.609

2.  MREIT with SENSE acceleration using a dedicated RF coil design.

Authors:  L Tugan Muftuler; Gang Chen; Mark J Hamamura; Seung Hoon Ha
Journal:  Physiol Meas       Date:  2009-07-30       Impact factor: 2.833

3.  Induced current magnetic resonance electrical impedance tomography of brain tissues based on the J-substitution algorithm: a simulation study.

Authors:  Yang Liu; Shanan Zhu; Bin He
Journal:  Phys Med Biol       Date:  2009-06-26       Impact factor: 3.609

4.  Reconstruction of dual-frequency conductivity by optimization of phase map in MREIT and MREPT.

Authors:  Oh In Kwon; Woo Chul Jeong; Saurav Z K Sajib; Hyung Joong Kim; Eung Je Woo; Tong In Oh
Journal:  Biomed Eng Online       Date:  2014-03-08       Impact factor: 2.819

5.  Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

Authors:  José P Marques; Daniel K Sodickson; Ozlem Ipek; Christopher M Collins; Rolf Gruetter
Journal:  Magn Reson Med       Date:  2014-08-05       Impact factor: 4.668

6.  Current density imaging using directly measured harmonic Bz data in MREIT.

Authors:  Chunjae Park; Oh In Kwon
Journal:  Comput Math Methods Med       Date:  2013-03-20       Impact factor: 2.238

7.  Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions.

Authors:  Munish Chauhan; Woo Chul Jeong; Hyung Joong Kim; Oh In Kwon; Eung Je Woo
Journal:  Biomed Eng Online       Date:  2013-08-27       Impact factor: 2.819