Literature DB >> 19640685

Position of the impacted third molar in relation to the mandibular canal. Diagnostic accuracy of cone beam computed tomography compared with panoramic radiography.

H Ghaeminia1, G J Meijer, A Soehardi, W A Borstlap, J Mulder, S J Bergé.   

Abstract

This study investigated the diagnostic accuracy of cone beam computed tomography (CBCT) compared to panoramic radiography in determining the anatomical position of the impacted third molar in relation with the mandibular canal. The study sample comprised 53 third molars from 40 patients with an increased risk of inferior alveolar nerve (IAN) injury. The panoramic and CBCT features (predictive variables) were correlated with IAN exposure and injury (outcome variables). Sensitivity and specificity of modalities in predicting IAN exposure were compared. The IAN was exposed in 23 cases during third molar removal and injury occurred in 5 patients. No significant difference in sensitivity and specificity was found between both modalities in predicting IAN exposure. To date, lingual position of the mandibular canal was significantly associated with IAN injury. CBCT was not more accurate at predicting IAN exposure during third molar removal, however, did elucidate the 3D relationship of the third molar root to the mandibular canal; the coronal sections allowed a bucco-lingual appreciation of the mandibular canal to identify cases in which a lingually placed IAN is at risk during surgery. This observation dictates the surgical approach how to remove the third molar, so the IAN will not be subjected to pressure.

Entities:  

Mesh:

Year:  2009        PMID: 19640685     DOI: 10.1016/j.ijom.2009.06.007

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  63 in total

1.  Necessity of 3D visualization for the removal of lower wisdom teeth: required sample size to prove non-inferiority of panoramic radiography compared to CBCT.

Authors:  Felix Roeder; Daniel Wachtlin; Ralf Schulze
Journal:  Clin Oral Investig       Date:  2011-04-26       Impact factor: 3.573

2.  Correlation of panoramic radiography and cone beam CT findings in the assessment of the relationship between impacted mandibular third molars and the mandibular canal.

Authors:  F S Neves; T C Souza; S M Almeida; F Haiter-Neto; D Q Freitas; F N Bóscolo
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

3.  Evaluation of a cone beam CT artefact reduction algorithm.

Authors:  B Bechara; C A McMahan; H Geha; M Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2012-02-23       Impact factor: 2.419

4.  A multivariate statistical analysis on variables affecting inferior alveolar nerve damage during third molar surgery.

Authors:  R Pippi; M Santoro
Journal:  Br Dent J       Date:  2015-08-28       Impact factor: 1.626

5.  Correlation of mandibular impacted tooth and bone morphology determined by cone beam computed topography on a premise of third molar operation.

Authors:  M A Momin; K Matsumoto; K Ejima; R Asaumi; T Kawai; Y Arai; K Honda; T Yosue
Journal:  Surg Radiol Anat       Date:  2012-11-13       Impact factor: 1.246

6.  Influence of cone beam CT on treatment plan before surgical intervention of mandibular third molars and impact of radiographic factors on deciding on coronectomy vs surgical removal.

Authors:  L H Matzen; J Christensen; H Hintze; S Schou; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

7.  Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth.

Authors:  B Bechara; C Alex McMahan; W S Moore; M Noujeim; F B Teixeira; H Geha
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

Review 8.  Efficacy of CBCT for assessment of impacted mandibular third molars: a review - based on a hierarchical model of evidence.

Authors:  L H Matzen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

9.  Can preoperative imaging help to predict postoperative outcome after wisdom tooth removal? A randomized controlled trial using panoramic radiography versus cone-beam CT.

Authors:  Maria Eugenia Guerrero; Raul Botetano; Jorge Beltran; Keith Horner; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2013-03-15       Impact factor: 3.573

10.  Detection accuracy of condylar bony defects in Promax 3D cone beam CT images scanned with different protocols.

Authors:  Z-L Zhang; J-G Cheng; G Li; X-Q Shi; J-Z Zhang; Z-Y Zhang; X-C Ma
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.