Literature DB >> 27472215

Optical coherence tomography characteristics of different types of big bubbles seen in deep anterior lamellar keratoplasty by the big bubble technique.

S L AlTaan1, K Termote2,3, M S Elalfy1, E Hogan1, R Werkmeister4, L Schmetterer4,5, S Holland2, H S Dua1.   

Abstract

PurposeTo define optical coherence tomography (OCT) characteristics of type-1, type-2, and mixed big bubbles (BB) seen in deep anterior lamellar keratoplasty.MethodsHuman sclero-corneal discs were obtained from UK (30) and Canada (16) eye banks. Air was injected into corneal stroma until a BB formed. UK samples were fixed in formalin before scanning with Fourier-domain (FD-OCT). One pair of each type of BB was scanned fresh. All BB obtained from Canada were scanned fresh with time-domain (TD-OCT). For each OCT machine used, type-1 BB from which Descemets membrane (DM) was partially peeled, were also scanned. The morphological characteristics of the scans were studied.ResultsFD-OCT of the posterior wall of type-1 (Dua's layer (DL) with DM) and type-2 BB (DM alone) both revealed a double-contour hyper-reflective curvilinear image with a hypo-reflective zone in between. The anterior line of type-2 BB was thinner than that seen with type-1 BB. In mixed BB, FD-OCT showed two separate curvilinear images. The anterior image was a single hyper-reflective line (DL), whereas the posterior image, representing the posterior wall of type-2 BB (DM) was made of two hyper-reflective lines with a dark space in between. TD-OCT images were similar with less defined component lines, but the entire extent of the BB could be visualised.ConclusionOn OCT examination the DM and DL present distinct features, which can help identify type-1, type-2, and mixed BB. These characteristics will help corneal surgeons interpret intraoperative OCT during lamellar corneal surgery.

Entities:  

Mesh:

Year:  2016        PMID: 27472215      PMCID: PMC5108003          DOI: 10.1038/eye.2016.129

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  18 in total

1.  Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment.

Authors:  Tanuj Dada; Ramanjit Sihota; Ritu Gadia; Anand Aggarwal; Subrata Mandal; Viney Gupta
Journal:  J Cataract Refract Surg       Date:  2007-05       Impact factor: 3.351

2.  In vivo corneal high-speed, ultra high-resolution optical coherence tomography.

Authors:  Viki Christopoulos; Larry Kagemann; Gadi Wollstein; Hiroshi Ishikawa; Michelle L Gabriele; Maciej Wojtkowski; Vivek Srinivasan; James G Fujimoto; Jay S Duker; Deepinder K Dhaliwal; Joel S Schuman
Journal:  Arch Ophthalmol       Date:  2007-08

3.  Performance of fourier domain vs. time domain optical coherence tomography.

Authors:  R Leitgeb; C Hitzenberger; Adolf Fercher
Journal:  Opt Express       Date:  2003-04-21       Impact factor: 3.894

4.  Anterior Segment Optical Coherence Tomography-Guided Management Algorithm for Descemet Membrane Detachment After Intraocular Surgery.

Authors:  Namrata Sharma; Sandeep Gupta; Prafulla Maharana; Prakash Shanmugam; Ritu Nagpal; Rasik B Vajpayee
Journal:  Cornea       Date:  2015-09       Impact factor: 2.651

5.  Intraoperative use of three-dimensional spectral-domain optical coherence tomography.

Authors:  Takeshi Ide; Jianhua Wang; Aizhu Tao; Theodore Leng; George D Kymionis; Terrence P O'Brien; Sonia H Yoo
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2010 Mar-Apr

6.  Big-bubble technique to bare Descemet's membrane in anterior lamellar keratoplasty.

Authors:  Mohammed Anwar; Klaus D Teichmann
Journal:  J Cataract Refract Surg       Date:  2002-03       Impact factor: 3.351

Review 7.  Clinical and research applications of anterior segment optical coherence tomography - a review.

Authors:  Jose Luiz Branco Ramos; Yan Li; David Huang
Journal:  Clin Exp Ophthalmol       Date:  2008-11-05       Impact factor: 4.207

Review 8.  Clinical applications of anterior segment optical coherence tomography.

Authors:  Su-Ho Lim
Journal:  J Ophthalmol       Date:  2015-03-03       Impact factor: 1.909

9.  Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography in the Measurement of Thinnest Corneal Thickness in Keratoconus.

Authors:  Chunxiao Wang; Xueying Xia; Bishan Tian; Shiyou Zhou
Journal:  J Ophthalmol       Date:  2015-06-25       Impact factor: 1.909

10.  Descemet stripping automated endothelial keratoplasty in Fuchs' corneal endothelial dystrophy: anterior segment optical coherence tomography and in vivo confocal microscopy analysis.

Authors:  Rita Mencucci; Eleonora Favuzza; Ruggero Tartaro; Massimo Busin; Gianni Virgili
Journal:  BMC Ophthalmol       Date:  2015-08-08       Impact factor: 2.209

View more
  6 in total

1.  Big double bubble trouble: in vivo real time demonstration of 'mixed-type bubble' and its consequent effects during deep anterior lamellar keratoplasty.

Authors:  Harathy Selvan; Shikha Yadav; Radhika Tandon
Journal:  Eye (Lond)       Date:  2018-02-16       Impact factor: 3.775

2.  Update on imaging modalities for ocular surface pathologies.

Authors:  Osmel P Alvarez; Anat Galor; Ghada AlBayyat; Carol L Karp
Journal:  Curr Ophthalmol Rep       Date:  2021-05-18

Review 3.  Intra-operative optical coherence tomography in glaucoma surgery-a systematic review.

Authors:  Bryan C H Ang; Sheng Yang Lim; Syril Dorairaj
Journal:  Eye (Lond)       Date:  2019-11-26       Impact factor: 3.775

Review 4.  Intraoperative optical coherence tomography in anterior segment surgeries.

Authors:  Jeewan S Titiyal; Manpreet Kaur; Ruchita Falera
Journal:  Indian J Ophthalmol       Date:  2017-02       Impact factor: 1.848

5.  Effect of Air Injection Depth on Big-bubble Formation in Lamellar Keratoplasty: an Ex Vivo Study.

Authors:  Young-Sik Yoo; Woong-Joo Whang; Min-Ji Kang; Je-Hyung Hwang; Yong-Soo Byun; Geunyoung Yoon; Sungwon Shin; Woonggyu Jung; Sucbei Moon; Choun-Ki Joo
Journal:  Sci Rep       Date:  2019-03-07       Impact factor: 4.379

Review 6.  An Overview of Intraoperative OCT-Assisted Lamellar Corneal Transplants: A Game Changer?

Authors:  Matteo Mario Carlà; Francesco Boselli; Federico Giannuzzi; Gloria Gambini; Tomaso Caporossi; Umberto De Vico; Luigi Mosca; Laura Guccione; Antonio Baldascino; Clara Rizzo; Raphael Kilian; Stanislao Rizzo
Journal:  Diagnostics (Basel)       Date:  2022-03-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.