Literature DB >> 19617601

Percutaneous left ventricular assist devices vs. intra-aortic balloon pump counterpulsation for treatment of cardiogenic shock: a meta-analysis of controlled trials.

Jin M Cheng1, Corstiaan A den Uil, Sanne E Hoeks, Martin van der Ent, Lucia S D Jewbali, Ron T van Domburg, Patrick W Serruys.   

Abstract

AIMS: Studies have compared safety and efficacy of percutaneous left ventricular assist devices (LVADs) with intra-aortic balloon pump (IABP) counterpulsation in patients with cardiogenic shock. We performed a meta-analysis of controlled trials to evaluate potential benefits of percutaneous LVAD on haemodynamics and 30-day survival. METHODS AND
RESULTS: Two independent investigators searched Medline, Embase, and Cochrane Central Register of Controlled Trials for all controlled trials using percutaneous LVAD in patients with cardiogenic shock, where after data were extracted using standardized forms. Weighted mean differences (MDs) were calculated for cardiac index (CI), mean arterial pressure (MAP), and pulmonary capillary wedge pressure (PCWP). Relative risks (RRs) were calculated for 30-day mortality, leg ischaemia, bleeding, and sepsis. In main analysis, trials were combined using inverse-variance random effects approach. Two trials evaluated the TandemHeart and a recent trial used the Impella device. After device implantation, percutaneous LVAD patients had higher CI (MD 0.35 L/min/m(2), 95% CI 0.09-0.61), higher MAP (MD 12.8 mmHg, 95% CI 3.6-22.0), and lower PCWP (MD -5.3 mm Hg, 95% CI -9.4 to -1.2) compared with IABP patients. Similar 30-day mortality (RR 1.06, 95% CI 0.68-1.66) was observed using percutaneous LVAD compared with IABP. No significant difference was observed in incidence of leg ischaemia (RR 2.59, 95% CI 0.75-8.97) in percutaneous LVAD patients compared with IABP patients. Bleeding (RR 2.35, 95% CI 1.40-3.93) was significantly more observed in TandemHeart patients compared with patients treated with IABP.
CONCLUSION: Although percutaneous LVAD provides superior haemodynamic support in patients with cardiogenic shock compared with IABP, the use of these more powerful devices did not improve early survival. These results do not yet support percutaneous LVAD as first-choice approach in the mechanical management of cardiogenic shock.

Entities:  

Mesh:

Year:  2009        PMID: 19617601     DOI: 10.1093/eurheartj/ehp292

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  96 in total

Review 1.  Surgical implant techniques of left ventricular assist devices: an overview of acute and durable devices.

Authors:  Bryan A Whitson
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

2.  Intraaortic balloon counterpulsation and microcirculation in cardiogenic shock complicating myocardial infarction: an IABP-SHOCK II substudy.

Authors:  Christian Jung; Georg Fuernau; Suzanne de Waha; Ingo Eitel; Steffen Desch; Gerhard Schuler; Hans R Figulla; Holger Thiele
Journal:  Clin Res Cardiol       Date:  2015-02-27       Impact factor: 5.460

Review 3.  Adult and pediatric mechanical circulation: a guide for the hematologist.

Authors:  Lisa Baumann Kreuziger; M Patricia Massicotte
Journal:  Hematology Am Soc Hematol Educ Program       Date:  2018-11-30

Review 4.  Cellular responses to mild heat stress.

Authors:  H G Park; S I Han; S Y Oh; H S Kang
Journal:  Cell Mol Life Sci       Date:  2005-01       Impact factor: 9.261

Review 5.  Phagocytosis of apoptotic cells: a matter of balance.

Authors:  C J G de Almeida; R Linden
Journal:  Cell Mol Life Sci       Date:  2005-07       Impact factor: 9.261

Review 6.  Management of refractory cardiogenic shock.

Authors:  Alex Reyentovich; Maya H Barghash; Judith S Hochman
Journal:  Nat Rev Cardiol       Date:  2016-06-30       Impact factor: 32.419

7.  Outcomes in patients undergoing percutaneous ventricular assist device implantation for cardiogenic shock.

Authors:  David D Berg; Devraj Sukul; Molly O'Brien; Benjamin M Scirica; Piotr S Sobieszczyk; Benjamin A Olenchock; Erin A Bohula; David A Morrow
Journal:  Eur Heart J Acute Cardiovasc Care       Date:  2015-04-30

Review 8.  ECMO as a bridge to high-risk rotablation of heavily calcified coronary arteries.

Authors:  P Dardas; N Mezilis; V Ninios; E K Theofilogiannakos; D Tsikaderis; N Tsotsolis; A Kolettas; N Nikoloudakis; A A Pitsis
Journal:  Herz       Date:  2012-03       Impact factor: 1.443

Review 9.  Defining the role for percutaneous mechanical circulatory support devices for medically refractory heart failure.

Authors:  Navin K Kapur; Marwan F Jumean
Journal:  Curr Heart Fail Rep       Date:  2013-06

10.  Percutaneous Hemodynamic Support in PCI.

Authors:  Jason Hatch; Dmitri Baklanov
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-04
View more