Literature DB >> 25931573

Outcomes in patients undergoing percutaneous ventricular assist device implantation for cardiogenic shock.

David D Berg1, Devraj Sukul2, Molly O'Brien1, Benjamin M Scirica1, Piotr S Sobieszczyk1, Benjamin A Olenchock1, Erin A Bohula1, David A Morrow3.   

Abstract

BACKGROUND: Percutaneous ventricular assist devices (PVADs) offer an important but resource-intensive option for management of severe cardiogenic shock (CS). Optimal selection of patients for PVAD support remains undefined. We investigated outcomes, including characteristics associated with in-hospital survival, during PVAD support for CS.
METHODS: We established a prospective quality improvement program among patients undergoing TandemHeart PVAD implantation for CS at Brigham and Women's Hospital (Boston, MA). We evaluated 65 consecutive patients between 2006 and 2014, analyzing demographic, clinical, laboratory, hemodynamic, and survival data.
RESULTS: Thirty-two patients (49.2%) survived to hospital discharge, of which 12 received destination surgical therapy. Baseline characteristics associated with survival included younger age (47 ± 15 years vs 61 ± 11 years; p<0.001), non-ischemic cardiomyopathy (NICMP) vs ischemic CMP (survival 70.4% vs 34.2%, p=0.004), and, paradoxically, lower presenting left ventricular ejection fraction (LVEF) (survival 66.7% for LVEF ⩽15%, 41.2% for LVEF 16-25%, 25.0% for LVEF >25%; p=0.010). Younger age (p=0.026) and NICMP (p=0.034) remained independent predictors of survival. Twenty-four hours after PVAD placement, a more modest increase in cardiac index (⩽0.75 L/min/m(2)) was associated with higher in-hospital mortality (OR 6.3, 95% CI 1.8-22.1), as was lack of improvement in serum anion gap (⩽2 mEq/L; OR 5.1, 95% CI 1.6-16.6).
CONCLUSIONS: Despite intensive care and provision of circulatory support, survival is poor in severe CS. Patients in CS with younger age and NICMP were more likely to survive to hospital discharge. Less robust hemodynamic improvement and persistent acidosis after 24 hours of PVAD support also identified patients less likely to survive. © The European Society of Cardiology 2015.

Entities:  

Keywords:  Shock; cardiomyopathy; cardiovascular critical care; mechanical circulatory support; ventricular assist device

Mesh:

Year:  2015        PMID: 25931573      PMCID: PMC4627853          DOI: 10.1177/2048872615584079

Source DB:  PubMed          Journal:  Eur Heart J Acute Cardiovasc Care        ISSN: 2048-8726


  13 in total

Review 1.  Percutaneous circulatory support in cardiogenic shock: interventional bridge to recovery.

Authors:  Biswajit Kar; Sukhdeep S Basra; Nishant R Shah; Pranav Loyalka
Journal:  Circulation       Date:  2012-04-10       Impact factor: 29.690

Review 2.  Mechanical circulatory support for advanced heart failure: patients and technology in evolution.

Authors:  Garrick C Stewart; Michael M Givertz
Journal:  Circulation       Date:  2012-03-13       Impact factor: 29.690

3.  The percutaneous ventricular assist device in severe refractory cardiogenic shock.

Authors:  Biswajit Kar; Igor D Gregoric; Sukhdeep S Basra; Gary M Idelchik; Pranav Loyalka
Journal:  J Am Coll Cardiol       Date:  2010-10-14       Impact factor: 24.094

4.  Direct comparison of percutaneous circulatory support systems in specific hemodynamic conditions in a porcine model.

Authors:  Petr Ostadal; Mikulas Mlcek; Frantisek Holy; Svatava Horakova; Stepan Kralovec; Jan Skoda; Jan Petru; Andreas Kruger; Vladimir Hrachovina; Tomas Svoboda; Otomar Kittnar; Vivek Y Reddy; Petr Neuzil
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-10-10

5.  Systemic inflammatory response syndrome after acute myocardial infarction complicated by cardiogenic shock.

Authors:  Shun Kohsaka; Venu Menon; April M Lowe; Michael Lange; Vladimir Dzavik; Lynn A Sleeper; Judith S Hochman
Journal:  Arch Intern Med       Date:  2005-07-25

Review 6.  Shock in acute myocardial infarction: the Cape Horn for trials?

Authors:  Holger Thiele; Bachir Allam; Gilles Chatellier; Gerhard Schuler; Antoine Lafont
Journal:  Eur Heart J       Date:  2010-07-07       Impact factor: 29.983

7.  Randomized comparison of intra-aortic balloon support with a percutaneous left ventricular assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shock.

Authors:  Holger Thiele; Peter Sick; Enno Boudriot; Klaus-Werner Diederich; Rainer Hambrecht; Josef Niebauer; Gerhard Schuler
Journal:  Eur Heart J       Date:  2005-02-25       Impact factor: 29.983

8.  A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock.

Authors:  Daniel Burkhoff; Howard Cohen; Corinna Brunckhorst; William W O'Neill
Journal:  Am Heart J       Date:  2006-09       Impact factor: 4.749

9.  Predictors of 30-day mortality in patients with refractory cardiogenic shock following acute myocardial infarction despite a patent infarct artery.

Authors:  Jason N Katz; Amanda L Stebbins; John H Alexander; Harmony R Reynolds; Karen S Pieper; Witold Ruzyllo; Karl Werdan; Alexander Geppert; Vladimir Dzavik; Frans Van de Werf; Judith S Hochman
Journal:  Am Heart J       Date:  2009-10       Impact factor: 4.749

10.  Intraaortic balloon support for myocardial infarction with cardiogenic shock.

Authors:  Holger Thiele; Uwe Zeymer; Franz-Josef Neumann; Miroslaw Ferenc; Hans-Georg Olbrich; Jörg Hausleiter; Gert Richardt; Marcus Hennersdorf; Klaus Empen; Georg Fuernau; Steffen Desch; Ingo Eitel; Rainer Hambrecht; Jörg Fuhrmann; Michael Böhm; Henning Ebelt; Steffen Schneider; Gerhard Schuler; Karl Werdan
Journal:  N Engl J Med       Date:  2012-08-26       Impact factor: 91.245

View more
  2 in total

1.  Multidisciplinary Code Shock Team in Cardiogenic Shock: A Canadian Centre Experience.

Authors:  Felicity Lee; Jordan H Hutson; Munir Boodhwani; Bernard McDonald; Derek So; Sophie De Roock; Fraser Rubens; Ellamae Stadnick; Marc Ruel; Michel Le May; Marino Labinaz; Kevin Chien; Habibat A Garuba; Lisa M Mielniczuk; Sharon Chih
Journal:  CJC Open       Date:  2020-03-27

2.  Predictors of intra-aortic balloon pump hemodynamic failure in non-acute myocardial infarction cardiogenic shock.

Authors:  Steven Hsu; Swetha Kambhampati; Christopher M Sciortino; Stuart D Russell; Steven P Schulman
Journal:  Am Heart J       Date:  2017-12-13       Impact factor: 4.749

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.