Literature DB >> 19616967

Improving FAIMS sensitivity using a planar geometry with slit interfaces.

Ridha Mabrouki1, Ryan T Kelly, David C Prior, Alexandre A Shvartsburg, Keqi Tang, Richard D Smith.   

Abstract

Differential mobility spectrometry or field asymmetric waveform ion mobility spectrometry (FAIMS) is gaining broad acceptance for analyses of gas-phase ions, especially in conjunction with largely orthogonal separation methods such as mass spectrometry (MS) and/or conventional (drift tube) ion mobility spectrometry. In FAIMS, ions are filtered while passing through a gap between two electrodes that may have planar or curved (in particular, cylindrical) geometry. Despite substantial inherent advantages of the planar configuration and its near-universal adoption in current stand-alone FAIMS devices, commercial FAIMS/MS systems have employed curved FAIMS geometries that can be more effectively interfaced to MS. Here we report a new planar (p-) FAIMS design with slit-shaped entrance and exit apertures that substantially increase ion transmission in and out of the analyzer. The entrance slit interface effectively couples p-FAIMS to multi-emitter electrospray ionization (ESI) sources, improving greatly the ion current introduced to the device and allowing liquid flow rates up to approximately 50 microL/min. The exit slit interface increases the transmission of ribbon-shaped ion beams output by the p-FAIMS to downstream stages such as a MS. Overall, the ion signal in ESI/FAIMS/MS analyses increases by over an order of magnitude without affecting FAIMS resolution.

Entities:  

Mesh:

Year:  2009        PMID: 19616967      PMCID: PMC2864548          DOI: 10.1016/j.jasms.2009.05.019

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  35 in total

1.  Optimization of the design and operation of FAIMS analyzers.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-01       Impact factor: 3.109

2.  Two-dimensional gas-phase separations coupled to mass spectrometry for analysis of complex mixtures.

Authors:  Keqi Tang; Fumin Li; Alexandre A Shvartsburg; Eric F Strittmatter; Richard D Smith
Journal:  Anal Chem       Date:  2005-10-01       Impact factor: 6.986

3.  Multidimensional separations of ubiquitin conformers in the gas phase: relating ion cross sections to H/D exchange measurements.

Authors:  Errol W Robinson; Evan R Williams
Journal:  J Am Soc Mass Spectrom       Date:  2005-09       Impact factor: 3.109

4.  Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry.

Authors:  Ryan T Kelly; Jason S Page; Quanzhou Luo; Ronald J Moore; Daniel J Orton; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

5.  Capillary-based multi nanoelectrospray emitters: improvements in ion transmission efficiency and implementation with capillary reversed-phase LC-ESI-MS.

Authors:  Ryan T Kelly; Jason S Page; Rui Zhao; Wei-Jun Qian; Heather M Mottaz; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2007-11-29       Impact factor: 6.986

6.  High-field asymmetric waveform ion mobility spectrometry coupled with liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-FAIMS-MS/MS) multi-component bioanalytical method development, performance evaluation and demonstration of the constancy of the compensation voltage with change of mobile phase composition or flow rate.

Authors:  Steven T Wu; Yuan-Qing Xia; Mohammed Jemal
Journal:  Rapid Commun Mass Spectrom       Date:  2007       Impact factor: 2.419

7.  Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS).

Authors:  Beata M Kolakowski; Zoltán Mester
Journal:  Analyst       Date:  2007-06-26       Impact factor: 4.616

8.  Analytical properties of the nanoelectrospray ion source.

Authors:  M Wilm; M Mann
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

9.  Analytical characterization of the electrospray ion source in the nanoflow regime.

Authors:  Ioan Marginean; Ryan T Kelly; David C Prior; Brian L LaMarche; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2008-07-29       Impact factor: 6.986

10.  Assessing the dynamic range and peak capacity of nanoflow LC-FAIMS-MS on an ion trap mass spectrometer for proteomics.

Authors:  Jesse D Canterbury; Xianhua Yi; Michael R Hoopmann; Michael J MacCoss
Journal:  Anal Chem       Date:  2008-08-12       Impact factor: 6.986

View more
  11 in total

Review 1.  Size, weight and position: ion mobility spectrometry and imaging MS combined.

Authors:  András Kiss; Ron M A Heeren
Journal:  Anal Bioanal Chem       Date:  2011-01-13       Impact factor: 4.142

2.  Performance Enhancements in Differential Ion Mobility Spectrometry-Mass Spectrometry (DMS-MS) by Using a Modified CaptiveSpray Source.

Authors:  Ri Wu; Wei-Jing Wu; Ze Wang; Y-L Elaine Wong; Y-L Winnie Hung; H T Wong; Xiangfeng Chen; T-W Dominic Chan
Journal:  J Am Soc Mass Spectrom       Date:  2018-08-16       Impact factor: 3.109

3.  On an aerodynamic mechanism to enhance ion transmission and sensitivity of FAIMS for nano-electrospray ionization-mass spectrometry.

Authors:  Satendra Prasad; Michael W Belford; Jean-Jacques Dunyach; Randy W Purves
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-30       Impact factor: 3.109

4.  Enhancing biological analyses with three dimensional field asymmetric ion mobility, low field drift tube ion mobility and mass spectrometry (μFAIMS/IMS-MS) separations.

Authors:  Xing Zhang; Yehia M Ibrahim; Tsung-Chi Chen; Jennifer E Kyle; Randolph V Norheim; Matthew E Monroe; Richard D Smith; Erin S Baker
Journal:  Analyst       Date:  2015-10-21       Impact factor: 4.616

5.  Ultrahigh-resolution differential ion mobility spectrometry using extended separation times.

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  Anal Chem       Date:  2010-11-30       Impact factor: 6.986

6.  Separation of peptide isomers with variant modified sites by high-resolution differential ion mobility spectrometry.

Authors:  Alexandre A Shvartsburg; Andrew J Creese; Richard D Smith; Helen J Cooper
Journal:  Anal Chem       Date:  2010-10-01       Impact factor: 6.986

7.  High-resolution differential ion mobility separations using helium-rich gases.

Authors:  Alexandre A Shvartsburg; William F Danielson; Richard D Smith
Journal:  Anal Chem       Date:  2010-03-15       Impact factor: 6.986

Review 8.  Review on ion mobility spectrometry. Part 1: current instrumentation.

Authors:  R Cumeras; E Figueras; C E Davis; J I Baumbach; I Gràcia
Journal:  Analyst       Date:  2015-03-07       Impact factor: 4.616

9.  Differential ion mobility separations of peptides with resolving power exceeding 50.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2010-01-01       Impact factor: 6.986

10.  Ultrafast differential ion mobility spectrometry at extreme electric fields coupled to mass spectrometry.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith; Martin Holden; Martyn Rush; Andrew Thompson; Danielle Toutoungi
Journal:  Anal Chem       Date:  2009-10-01       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.