Literature DB >> 23837536

Image quality improvements in C-Arm CT (CACT) for liver oncology applications: preliminary study in rabbits.

Vania Tacher1, Nikhil Bhagat, Pramod V Rao, Mingde Lin, Dirk Schäfer, Niels Noordhoek, Peter Eshuis, Alessandro Radaelli, Eleni Liapi, Michael Grass, Jean-François Geschwind.   

Abstract

INTRODUCTION: C-Arm CT (CACT) is a new imaging modality in liver oncology therapy that allows for the acquisition of 3D images intra-procedurally. CACT has been used to enhance intra-arterial therapies for the liver by improving lesion detection, avoiding non-target embolization, and allowing for more selective delivery of agents. However, one of the limitations of this technology is image artifacts created by respiratory motion.
PURPOSE: To determine in this preliminary study improvements in image acquisition, motion compensation, and high resolution 3D reconstruction that can improve CACT image quality (IQ).
MATERIAL AND METHODS: Three adult male New Zealand white rabbits were used for this study. First, a control rabbit was used to select the best x-ray acquisition imaging protocol and then two rabbits were implanted with liver tumor to further develop 3D image reconstruction and motion compensation algorithms.
RESULTS: The best IQ was obtained using the low 80 kVp protocol with motion compensated reconstruction with high resolution and fast acquisition speed (60 fps, 5 s/scan, and 312 images).
CONCLUSION: IQ improved by: (1) decreasing acquisition time, (2) applying motion-compensated reconstruction, and (3) high resolution 3D reconstruction. The findings of this study can be applied to future animal studies and eventually could be translated into the clinical environment.

Entities:  

Mesh:

Year:  2013        PMID: 23837536      PMCID: PMC3859124          DOI: 10.3109/13645706.2013.788028

Source DB:  PubMed          Journal:  Minim Invasive Ther Allied Technol        ISSN: 1364-5706            Impact factor:   2.442


  19 in total

1.  Optimized radiographic spectra for small animal digital subtraction angiography.

Authors:  Ming De Lin; Ehsan Samei; Cristian T Badea; Terry T Yoshizumi; G Allan Johnson
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

2.  Cone-beam CT with flat-panel-detector digital angiography system: early experience in abdominal interventional procedures.

Authors:  Shozo Hirota; Norio Nakao; Satoshi Yamamoto; Kaoru Kobayashi; Hiroaki Maeda; Reiichi Ishikura; Koui Miura; Kiyoshi Sakamoto; Ken Ueda; Rika Baba
Journal:  Cardiovasc Intervent Radiol       Date:  2006 Nov-Dec       Impact factor: 2.740

Review 3.  C-arm computed tomography for guiding hepatic vascular interventions.

Authors:  Michael J Wallace
Journal:  Tech Vasc Interv Radiol       Date:  2007-03

4.  Impact of C-arm CT on hepatic arterial interventions for hepatic malignancies.

Authors:  Michael J Wallace; Ravi Murthy; Paresh P Kamat; Teri Moore; Sujaya H Rao; Joe Ensor; Sanjay Gupta; Kamran Ahrar; David C Madoff; Stephen E McRae; Marshall E Hicks
Journal:  J Vasc Interv Radiol       Date:  2007-12       Impact factor: 3.464

5.  Application- and patient size-dependent optimization of x-ray spectra for CT.

Authors:  Willi A Kalender; Paul Deak; Markus Kellermeier; Marcel van Straten; Sabrina V Vollmar
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

Review 6.  Three-dimensional C-arm cone-beam CT: applications in the interventional suite.

Authors:  Michael J Wallace; Michael D Kuo; Craig Glaiberman; Christoph A Binkert; Robert C Orth; Gilles Soulez
Journal:  J Vasc Interv Radiol       Date:  2008-04-10       Impact factor: 3.464

7.  Impact of multidetector CT hepatic arteriography on the planning of chemoembolization treatment of hepatocellular carcinoma.

Authors:  D Y Sze; M K Razavi; S K So; R B Jeffrey
Journal:  AJR Am J Roentgenol       Date:  2001-12       Impact factor: 3.959

8.  Intraprocedural C-arm dual-phase cone-beam CT: can it be used to predict short-term response to TACE with drug-eluting beads in patients with hepatocellular carcinoma?

Authors:  Romaric Loffroy; MingDe Lin; Gayane Yenokyan; Pramod P Rao; Nikhil Bhagat; Niels Noordhoek; Alessandro Radaelli; Järl Blijd; Eleni Liapi; Jean-François Geschwind
Journal:  Radiology       Date:  2012-11-09       Impact factor: 11.105

9.  Brain imaging with a flat detector C-arm : Technique and clinical interest of XperCT.

Authors:  M Söderman; D Babic; S Holmin; T Andersson
Journal:  Neuroradiology       Date:  2008-06-17       Impact factor: 2.804

10.  Visualization of hypervascular liver lesions During TACE: comparison of angiographic C-arm CT and MDCT.

Authors:  Bernhard C Meyer; Bernd B Frericks; Maerthe Voges; Michael Borchert; Peter Martus; Joern Justiz; Karl-Juergen Wolf; Frank K Wacker
Journal:  AJR Am J Roentgenol       Date:  2008-04       Impact factor: 3.959

View more
  5 in total

1.  Dose reduction in cone-beam CT scanning for intracranial stent deployment before coil embolization of intracranial wide-neck aneurysms.

Authors:  Takumi Kuriyama; Nobuyuki Sakai; Norimitsu Niida; Masaki Sueoka; Mikiya Beppu; Chihebeddine Dahmani; Iwao Kojima; Chiaki Sakai; Hirotoshi Imamura; Katsuhiro Masago; Nobuyuki Katakami
Journal:  Interv Neuroradiol       Date:  2016-02-24       Impact factor: 1.610

Review 2.  How I do it: Cone-beam CT during transarterial chemoembolization for liver cancer.

Authors:  Vania Tacher; Alessandro Radaelli; MingDe Lin; Jean-François Geschwind
Journal:  Radiology       Date:  2015-02       Impact factor: 11.105

3.  Dual-phase cone-beam computed tomography to see, reach, and treat hepatocellular carcinoma during drug-eluting beads transarterial chemo-embolization.

Authors:  Vania Tacher; Mingde Lin; Nikhil Bhagat; Nadine Abi Jaoudeh; Alessandro Radaelli; Niels Noordhoek; Bart Carelsen; Bradford J Wood; Jean-François Geschwind
Journal:  J Vis Exp       Date:  2013-12-02       Impact factor: 1.355

4.  Evaluation of a Motion Correction Algorithm for C-Arm Computed Tomography Acquired During Transarterial Chemoembolization.

Authors:  Lena S Becker; Marcel Gutberlet; Sabine K Maschke; Thomas Werncke; Cornelia L A Dewald; Christian von Falck; Arndt Vogel; Roman Kloeckner; Bernhard C Meyer; Frank Wacker; Jan B Hinrichs
Journal:  Cardiovasc Intervent Radiol       Date:  2020-12-06       Impact factor: 2.740

5.  Effectuality study of a 3D motion correction algorithm in C-arm CTs of severely impaired image quality during transarterial chemoembolization.

Authors:  Bernhard C Meyer; Jan B Hinrichs; Lena S Becker; Cornelia L A Dewald; Christian von Falck; Thomas Werncke; Sabine K Maschke; Roman Kloeckner; Frank K Wacker
Journal:  Cancer Imaging       Date:  2022-07-30       Impact factor: 5.605

  5 in total