Literature DB >> 19609032

A novel poly(vinyl chloride) matrix membrane sensor for batch and flow-injection determinations of thiocyanate, cyanide and some metal ions.

Saad S M Hassan1, Ibrahim H A Badr, Ayman H Kamel, Mona S Mohamed.   

Abstract

A poly(vinyl chloride) matrix membrane sensor for the selective determination of thiocyanate has been developed based on the use of copper(II)-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex (Cu-PADAP) as a novel charged carrier, and o-nitrophenyloctyl ether (o-NPOE) as a solvent mediator. The sensor displays a significantly enhanced response towards SCN(-) ions over the concentration range 7.0 x 10(-6) to 1.0 x 10(-2) mol L(-1) with a detection limit of 5.6 x 10(-6) mol L(-1) and a calibration slope of -57.5 +/- 0.5 mV decade(-1). The sensor exhibits a long life-span, long-term stability, high reproducibility, and a fast response time. The selectivity coefficients of some anions were calculated using the separate solutions method, and found to be in the following order: SCN(-) > ClO(4)(-) > I(-) > Sal(-) > NO(2)(-) > Br(-) > NO(3)(-) = CH(3)COO(-) > Cl(-) > SO(4)(2-) = PO(4)(3-). The effects of the pH and ionic membrane additives (e.g. tridodecylmethylammonium chloride, TDMAC and potassium tetrakis[bis(3,5-trifluoromethyl)phenyl] borate, KTFPB) were examined. The sensor was used for the determination of SCN(-) ions in saliva and urine samples collected from some smoker and non-smoker donors. The developed sensor was also applied to determine the cyanide content in electroplating waste water samples after its conversion into thiocyanate. The application of the sensor to monitor the potentiometric titration of Ag(+) and Hg(2+) using SCN(-) resulted in sharp inflection breaks at the equivalent points. The data obtained using the proposed sensor correlate very well with results collected using the standard methods of thiocyanate, cyanide and metal analysis.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19609032     DOI: 10.2116/analsci.25.911

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  9 in total

1.  The analysis of protein-bound thiocyanate in plasma of smokers and non-smokers as a marker of cyanide exposure.

Authors:  Stephanie L Youso; Gary A Rockwood; Brian A Logue
Journal:  J Anal Toxicol       Date:  2012-04-02       Impact factor: 3.367

2.  Paper-Based Potentiometric Sensors for Nicotine Determination in Smokers' Sweat.

Authors:  Abd El-Galil E Amr; Ayman H Kamel; Abdulrahman A Almehizia; Ahmed Y A Sayed; Elsayed A Elsayed; Hisham S M Abd-Rabboh
Journal:  ACS Omega       Date:  2021-04-22

3.  Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination.

Authors:  Ayman H Kamel; Abd El-Galil E Amr; Abdulrahman A Almehizia; Elsayed A Elsayed; Gaber O Moustafa
Journal:  RSC Adv       Date:  2021-08-18       Impact factor: 4.036

4.  A New Validated Potentiometric Method for Sulfite Assay in Beverages Using Cobalt(II) Phthalocyanine as a Sensory Recognition Element.

Authors:  Saad S M Hassan; Ayman H Kamel; Abd El-Galil E Amr; Hisham S M Abd-Rabboh; Mohamed A Al-Omar; Elsayed A Elsayed
Journal:  Molecules       Date:  2020-07-06       Impact factor: 4.411

5.  Integrated all-solid-state sulfite sensors modified with two different ion-to-electron transducers: rapid assessment of sulfite in beverages.

Authors:  Hisham S M Abd-Rabboh; Abd El-Galil E Amr; Ayman H Kamel; Mohamed A Al-Omar; Ahmed Y A Sayed
Journal:  RSC Adv       Date:  2021-01-19       Impact factor: 3.361

6.  Effective screen-printed potentiometric devices modified with carbon nanotubes for the detection of chlorogenic acid: application to food quality monitoring.

Authors:  Hisham S M Abd-Rabboh; Abd El-Galil E Amr; Ahmed M Naglah; Abdulrahman A Almehizia; Ayman H Kamel
Journal:  RSC Adv       Date:  2021-12-02       Impact factor: 4.036

7.  Potentiometric PVC-Membrane-Based Sensor for Dimethylamine Assessment Using A Molecularly Imprinted Polymer as A Sensory Recognition Element.

Authors:  Saad S M Hassan; Abd El-Galil E Amr; Heba Abd El-Naby; Mohamed A Al-Omar; Ayman H Kamel; Nagy M Khalifa
Journal:  Polymers (Basel)       Date:  2019-10-16       Impact factor: 4.329

8.  Modified Potentiometric Screen-Printed Electrodes Based on Imprinting Character for Sodium Deoxycholate Determination.

Authors:  Ayman H Kamel; Samar Ezzat; Mona A Ahmed; Abd El-Galil E Amr; Abdulrahman A Almehizia; Mohamed A Al-Omar
Journal:  Biomolecules       Date:  2020-02-06

9.  Novel Validated Analytical Method Based on Potentiometric Transduction for the Determination of Citicoline Psychostimulant/Nootropic Agent.

Authors:  Ayman H Kamel; Abd El-Galil E Amr; Hoda R Galal; Abdulrahman A Almehizia
Journal:  Molecules       Date:  2020-07-31       Impact factor: 4.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.