Literature DB >> 19588171

Biomechanical analysis of expansion screws and cortical screws used for ventral plate fixation on the cervical spine.

Klaus Röhl1, Bernhard Ullrich, Gerd Huber, Michael M Morlock.   

Abstract

Compared to bicortical screws, the surgical risk of injuring intraspinal structures can be minimized with the use of monocortical screws. However, this reduction should not be achieved at the expense of the stability of the fixation. With monocortical stabilization, the expansion screws have the potential of absorbing high loads. Therefore, they are expected to be a suitable alternative to bicortical screws for revision surgeries and in osteoporotic bone. The purpose of this in vitro study was to investigate the stiffness of the two screw-plate systems used for ventral stabilization of the cervical spine, by focusing on the suitability of expansion screws as tools for revision treatments. The study was conducted in ten functional units of human cervical spines. The device sample stiffness was determined for four conditions using a turning moment of 2.25 N m each around one of the three principle axes. The conditions were native, destabilized, primarily stabilized with one of the screw-plate systems, followed by secondary stabilization using the expansion screw implant. The stabilized samples achieved a comparable, in most cases higher stiffness than the native samples. The samples undergoing secondary stabilization using expansion screws tend to display greater stiffness for all three axes compared to the primarily stabilized samples. The achieved tightening moment of the screws was higher than the one achieved with primary fixation. Both plates revealed similar primary stability. Revision surgeries with secondary instrumentation achieve a high stiffness of the screwed up segments. Monocortical expansion screws combined with a trapezoidal plate allow ventral stabilization of the cervical spine that is comparable to the plate fixation using bicortical screws.

Entities:  

Mesh:

Year:  2009        PMID: 19588171      PMCID: PMC2899537          DOI: 10.1007/s00586-009-1087-5

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  28 in total

Review 1.  [Biomechanical and clinical aspects of spondylodesis of the lower cervical spine. Methods and implants].

Authors:  C Ulrich; J Nothwang
Journal:  Orthopade       Date:  1999-08       Impact factor: 1.087

2.  [Fractures and instability of the cervical spine].

Authors:  V Bühren
Journal:  Unfallchirurg       Date:  2002-11       Impact factor: 1.000

3.  Comparative experimental biomechanical study of different types of stabilization methods of the lower cervical spine.

Authors:  R Kalff; C Ulrich; L Claes; H J Wilke; W Grote
Journal:  Neurosurg Rev       Date:  1992       Impact factor: 3.042

4.  Cervical spine locking plate: in vitro biomechanical testing.

Authors:  S A Smith; R W Lindsey; B J Doherty; J W Alexander; J H Dickson
Journal:  Eur Spine J       Date:  1993-03       Impact factor: 3.134

5.  Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants.

Authors:  H J Wilke; K Wenger; L Claes
Journal:  Eur Spine J       Date:  1998       Impact factor: 3.134

6.  Performance of ventral spondylodesis screws in cervical vertebrae of varying bone mineral density.

Authors:  P M Zink
Journal:  Spine (Phila Pa 1976)       Date:  1996-01-01       Impact factor: 3.468

7.  Analysis and measurement of neck loads.

Authors:  S P Moroney; A B Schultz; J A Miller
Journal:  J Orthop Res       Date:  1988       Impact factor: 3.494

8.  Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws.

Authors:  T C Ryken; J D Clausen; V C Traynelis; V K Goel
Journal:  J Neurosurg       Date:  1995-08       Impact factor: 5.115

9.  Anterior cervical fusion with the Orion locking plate system.

Authors:  V Heidecke; N G Rainov; W Burkert
Journal:  Spine (Phila Pa 1976)       Date:  1998-08-15       Impact factor: 3.468

10.  Anterior plate fixation of traumatic lesions of the lower cervical spine.

Authors:  J C de Oliveira
Journal:  Spine (Phila Pa 1976)       Date:  1987-05       Impact factor: 3.468

View more
  2 in total

1.  Hounsfield units as predictor for cage subsidence and loss of reduction: following posterior-anterior stabilization in thoracolumbar spine fractures.

Authors:  Bernhard Wilhelm Ullrich; Philipp Schenk; Ulrich J Spiegl; Thomas Mendel; Gunther Olaf Hofmann
Journal:  Eur Spine J       Date:  2018-10-19       Impact factor: 3.134

2.  Biomechanical study of a novel self-locking plate system for anterior cervical fixation.

Authors:  Lifeng Lao; Qianyi Li; Guibin Zhong; Chao Song; Yuanchao Li; Mingze Xu; Zude Liu
Journal:  J Orthop Surg Res       Date:  2014-11-27       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.