Automatic slice positioning (ASP) for passive real-time tracking of interventional devices using projection-reconstruction imaging with echo-dephasing (PRIDE).

S Patil1, O Bieri, P Jhooti, K Scheffler.   

Abstract

A novel and fast approach for passive real-time tracking of interventional devices using paramagnetic markers, termed "projection-reconstruction imaging with echo-dephasing" (PRIDE) is presented. PRIDE is based on the acquisition of echo-dephased projections along all three physical axes. Dephasing is preferably set to 4pi within each projection ensuring that background tissues do not contribute to signal formation and thus appear heavily suppressed. However, within the close vicinity of the paramagnetic marker, local gradient fields compensate for the intrinsic dephasing to form an echo. Successful localization of the paramagnetic marker with PRIDE is demonstrated in vitro and in vivo in the presence of different types of off-resonance (air/tissue interfaces, main magnetic field inhomogeneities, etc). In order to utilize the PRIDE sequence for vascular interventional applications, it was interleaved with balanced steady-state free precession (bSSFP) to provide positional updates to the imaged slice using a dedicated real-time feedback link. Active slice positioning (ASP) with PRIDE is demonstrated in vitro, requiring approximately 20 ms for the positional update to the imaging sequence, comparable to existing active tracking methods. (c) 2009 Wiley-Liss, Inc.

Mesh:

Year:  2009        PMID: 19585605     DOI: 10.1002/mrm.22080

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Susceptibility artifacts from metallic markers and cardiac catheterization devices on a high-performance 0.55 T MRI system.

Authors:  Burcu Basar; Merdim Sonmez; Dursun Korel Yildirim; Ram Paul; Daniel A Herzka; Ozgur Kocaturk; Robert J Lederman; Adrienne E Campbell-Washburn
Journal:  Magn Reson Imaging       Date:  2020-12-09       Impact factor: 2.546

Review 2.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11

3.  Wireless MR tracking of interventional devices using phase-field dithering and projection reconstruction.

Authors:  Martin A Rube; Andrew B Holbrook; Benjamin F Cox; J Graeme Houston; Andreas Melzer
Journal:  Magn Reson Imaging       Date:  2014-03-17       Impact factor: 2.546

4.  In-bore setup and software for 3T MRI-guided transperineal prostate biopsy.

Authors:  Junichi Tokuda; Kemal Tuncali; Iulian Iordachita; Sang-Eun Song; Andriy Fedorov; Sota Oguro; Andras Lasso; Fiona M Fennessy; Clare M Tempany; Nobuhiko Hata
Journal:  Phys Med Biol       Date:  2012-09-05       Impact factor: 3.609

Review 5.  Magnetic Resonance-Guided Passive Catheter Tracking for Endovascular Therapy.

Authors:  Fabio Settecase; Alastair J Martin; Prasheel Lillaney; Aaron Losey; Steven W Hetts
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266