Literature DB >> 19567852

Survival and clinical function of cemented and uncemented prostheses in total knee replacement: a meta-analysis.

R Gandhi1, D Tsvetkov, J R Davey, N N Mahomed.   

Abstract

Using meta-analysis we compared the survival and clinical outcomes of cemented and uncemented techniques in primary total knee replacement. We reviewed randomised controlled trials and observational studies comparing cemented and uncemented fixation. Our primary outcome was survival of the implant free of aseptic loosening. Our secondary outcome was joint function as measured by the Knee Society score. We identified 15 studies that met our final eligibility criteria. The combined odds ratio for failure of the implant due to aseptic loosening for the uncemented group was 4.2 (95% confidence interval (CI) 2.7 to 6.5) (p < 0.0001). Subgroup analysis of data only from randomised controlled trials showed no differences between the groups for odds of aseptic loosening (odds ratio 1.9, 95% CI 0.55 to 6.40, p = 0.314). The weighted mean difference for the Knee Society score was 0.005 (95% CI -0.26 to 0.26) (p = 0.972). There was improved survival of the cemented compared to uncemented implants, with no statistically significant difference in the mean Knee Society score between groups for all pooled data.

Mesh:

Year:  2009        PMID: 19567852     DOI: 10.1302/0301-620X.91B7.21702

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  47 in total

1.  Management of knee injuries: consensus-based indications from a large community of orthopaedic surgeons.

Authors:  Federico Cabitza; Vincenza Ragone; Paolo Arrigoni; Jón Karlsson; Pietro Randelli
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-24       Impact factor: 4.342

2.  No early tibial tray loosening after surface cementing technique in mobile-bearing TKA.

Authors:  Roberto Rossi; Matteo Bruzzone; Davide Edoardo Bonasia; Andrea Ferro; Filippo Castoldi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-10       Impact factor: 4.342

3.  Value comparison of humeral component press-fit and cemented techniques in reverse shoulder arthroplasty.

Authors:  Derek D Berglund; Dragomir Mijic; Tsun Yee Law; Jennifer Kurowicki; Samuel Rosas; Jonathan C Levy
Journal:  J Shoulder Elbow Surg       Date:  2018-11-02       Impact factor: 3.019

4.  Similar survival between uncemented and cemented fixation prostheses in total knee arthroplasty: a meta-analysis and systematic comparative analysis using registers.

Authors:  Hongchuan Wang; Hua Lou; Huiwei Zhang; Junwei Jiang; Kai Liu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-12-14       Impact factor: 4.342

5.  CORR Insights ®: Trabecular metal in total knee arthroplasty associated with higher knee scores: a randomized controlled trial.

Authors:  Geert Pagenstert
Journal:  Clin Orthop Relat Res       Date:  2013-08-28       Impact factor: 4.176

6.  [Long-term results in total knee arthroplasty. A meta-analysis of revision rates and functional outcome].

Authors:  J Lützner; U Hübel; S Kirschner; K-P Günther; F Krummenauer
Journal:  Chirurg       Date:  2011-07       Impact factor: 0.955

7.  Cemented versus cementless fixation in total knee arthroplasty.

Authors:  Fabrizio Matassi; Christian Carulli; Roberto Civinini; Massimo Innocenti
Journal:  Joints       Date:  2014-01-08

8.  Similar survival between screw cementless and cemented tibial components in young patients with osteoarthritis.

Authors:  Alejandro Lizaur-Utrilla; Francisco A Miralles-Muñoz; Fernando A Lopez-Prats
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11-08       Impact factor: 4.342

9.  An in vitro comparison of tibial tray cementation using gun pressurization or pulsed lavage.

Authors:  Ulf J Schlegel; Klaus Püschel; Michael M Morlock; Katrin Nagel
Journal:  Int Orthop       Date:  2014-03-12       Impact factor: 3.075

10.  Predictive factors for failure after total knee replacement revision.

Authors:  Rafael Luque; Belen Rizo; Antonio Urda; Rodrigo Garcia-Crespo; Enrique Moro; Fernando Marco; Luis López-Duran
Journal:  Int Orthop       Date:  2014-01-09       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.