Literature DB >> 19544059

Removal of visual feedback alters muscle activity and reduces force variability during constant isometric contractions.

Harsimran S Baweja1, Bhavini K Patel, Julie D Martinkewiz, Julie Vu, Evangelos A Christou.   

Abstract

The purpose of this study was to compare force accuracy, force variability and muscle activity during constant isometric contractions at different force levels with and without visual feedback and at different feedback gains. In experiment 1, subjects were instructed to accurately match the target force at 2, 15, 30, 50, and 70% of their maximal isometric force with abduction of the index finger and maintain their force even in the absence of visual feedback. Each trial lasted 22 s and visual feedback was removed from 8-12 to 16-20 s. Each subject performed 6 trials at each target force, half with visual gain of 51.2 pixels/N and the rest with a visual gain of 12.8 pixels/N. Force error was calculated as the root mean square error of the force trace from the target line. Force variability was quantified as the standard deviation and coefficient of variation (CVF) of the force trace. The EMG activity of the agonist (first dorsal interosseus; FDI) was measured with bipolar surface electrodes placed distal to the innervation zone. Independent of visual gain and force level, subjects exhibited lower force error with the visual feedback condition (2.53 +/- 2.95 vs. 2.71 +/- 2.97 N; P < 0.01); whereas, force variability was lower when visual feedback was removed (CVF: 4.06 +/- 3.11 vs. 4.47 +/- 3.14, P < 0.01). The EMG activity of the FDI muscle was higher during the visual feedback condition and this difference increased especially at higher force levels (70%: 370 +/- 149 vs. 350 +/- 143 microV, P < 0.01). Experiment 2 examined whether the findings of experiment 1 were driven by the higher force levels and proximity in the gain of visual feedback. Subjects performed constant isometric contractions with the abduction of the index finger at an absolute force of 2 N, with two distinct feedback gains of 15 and 3,000 pixels/N. In agreement with the findings of experiment 1, subjects exhibited lower force error in the presence of visual feedback especially when the feedback gain was high (0.057 +/- 0.03 vs. 0.095 +/- 0.05 N). However, force variability was not affected by the vastly distinct feedback gains at this force, which supported and extended the findings from experiment 1. Our findings demonstrate that although removal of visual feedback amplifies force error, it can reduce force variability during constant isometric contractions due to an altered activation of the primary agonist muscle most likely at moderate force levels in young adults.

Entities:  

Mesh:

Year:  2009        PMID: 19544059      PMCID: PMC3631578          DOI: 10.1007/s00221-009-1883-5

Source DB:  PubMed          Journal:  Exp Brain Res        ISSN: 0014-4819            Impact factor:   1.972


  37 in total

1.  Effects of aging on force variability, single motor unit discharge patterns, and the structure of 10, 20, and 40 Hz EMG activity.

Authors:  David E Vaillancourt; Lars Larsson; Karl M Newell
Journal:  Neurobiol Aging       Date:  2003 Jan-Feb       Impact factor: 4.673

2.  Subthalamic nucleus and internal globus pallidus scale with the rate of change of force production in humans.

Authors:  David E Vaillancourt; Mary A Mayka; Keith R Thulborn; Daniel M Corcos
Journal:  Neuroimage       Date:  2004-09       Impact factor: 6.556

3.  Independence between the amount and structure of variability at low force levels.

Authors:  Jacob J Sosnoff; Andrew D Valantine; Karl M Newell
Journal:  Neurosci Lett       Date:  2005-09-26       Impact factor: 3.046

4.  Information processing limitations with aging in the visual scaling of isometric force.

Authors:  Jacob J Sosnoff; Karl M Newell
Journal:  Exp Brain Res       Date:  2005-11-23       Impact factor: 1.972

5.  Aging, visual intermittency, and variability in isometric force output.

Authors:  Jacob J Sosnoff; Karl M Newell
Journal:  J Gerontol B Psychol Sci Soc Sci       Date:  2006-03       Impact factor: 4.077

6.  Visuomotor contribution to force variability in the plantarflexor and dorsiflexor muscles.

Authors:  Brian L Tracy
Journal:  Hum Mov Sci       Date:  2007-09-04       Impact factor: 2.161

Review 7.  Common drive of motor units in regulation of muscle force.

Authors:  C J De Luca; Z Erim
Journal:  Trends Neurosci       Date:  1994-07       Impact factor: 13.837

Review 8.  Cortical drives to human muscle: the Piper and related rhythms.

Authors:  P Brown
Journal:  Prog Neurobiol       Date:  2000-01       Impact factor: 11.685

9.  Expiratory resistive loaded breathing in humans increases fluctuations of force production in submaximal isometric quadriceps contractions.

Authors:  Duncan L Turner
Journal:  Neurosci Lett       Date:  2002-08-02       Impact factor: 3.046

10.  The 1- to 2-Hz oscillations in muscle force are exacerbated by stress, especially in older adults.

Authors:  Evangelos A Christou; Jennifer M Jakobi; Ashley Critchlow; Monika Fleshner; Roger M Enoka
Journal:  J Appl Physiol (1985)       Date:  2004-07
View more
  40 in total

1.  Imperceptible electrical noise attenuates isometric plantar flexion force fluctuations with correlated reductions in postural sway.

Authors:  Fernando Henrique Magalhães; André Fabio Kohn
Journal:  Exp Brain Res       Date:  2011-12-24       Impact factor: 1.972

2.  Increased voluntary drive is associated with changes in common oscillations from 13 to 60 Hz of interference but not rectified electromyography.

Authors:  Osmar P Neto; Harsimran S Baweja; Evangelos A Christou
Journal:  Muscle Nerve       Date:  2010-09       Impact factor: 3.217

3.  Rectification of the EMG signal impairs the identification of oscillatory input to the muscle.

Authors:  Osmar Pinto Neto; Evangelos A Christou
Journal:  J Neurophysiol       Date:  2009-12-23       Impact factor: 2.714

4.  Timing and visual feedback constraints on repetitive finger force production.

Authors:  Amanda S Therrien; Ramesh Balasubramaniam
Journal:  Exp Brain Res       Date:  2010-04       Impact factor: 1.972

5.  Visual information gain and task asymmetry interact in bimanual force coordination and control.

Authors:  Xiaogang Hu; Karl M Newell
Journal:  Exp Brain Res       Date:  2011-06-11       Impact factor: 1.972

6.  10 Hz periodic component influences lower frequency component of the physiological tremor at low force levels.

Authors:  Hiroshi Endo; Koichi Kawahara
Journal:  Eur J Appl Physiol       Date:  2011-03-12       Impact factor: 3.078

7.  Effects of visual feedback absence on force control during isometric contraction.

Authors:  Eloisa Limonta; Susanna Rampichini; Emiliano Cè; Fabio Esposito
Journal:  Eur J Appl Physiol       Date:  2014-11-04       Impact factor: 3.078

8.  Sinusoidal vibrotactile stimulation differentially improves force steadiness depending on contraction intensity.

Authors:  Carina Marconi Germer; Luciana Sobral Moreira; Leonardo Abdala Elias
Journal:  Med Biol Eng Comput       Date:  2019-06-14       Impact factor: 2.602

9.  Visual information processing in older adults: reaction time and motor unit pool modulation.

Authors:  MinHyuk Kwon; Evangelos A Christou
Journal:  J Neurophysiol       Date:  2018-09-12       Impact factor: 2.714

10.  Greater amount of visual feedback decreases force variability by reducing force oscillations from 0-1 and 3-7 Hz.

Authors:  Harsimran S Baweja; Deanna M Kennedy; Julie Vu; David E Vaillancourt; Evangelos A Christou
Journal:  Eur J Appl Physiol       Date:  2009-12-02       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.