Literature DB >> 19536600

Development of a noise reduction filter algorithm for pediatric body images in multidetector CT.

Eiji Nishimaru1, Katsuhiro Ichikawa, Izumi Okita, Yukihiro Tomoshige, Takehiro Kurokawa, Yuko Nakamura, Masayuki Suzuki.   

Abstract

Recently, several types of post-processing image filter which was designed to reduce noise allowing a corresponding dose reduction in CT images have been proposed and these were reported to be useful for noise reduction of CT images of adult patients. However, these have not been reported on adaptation for pediatric patients. Because they are not very effective with small (<20 cm) display fields of view, they could not be used for pediatric (e.g., premature babies and infants) body CT images. In order to solve this restriction, we have developed a new noise reduction filter algorithm which can be applicable for pediatric body CT images. This algorithm is based on a three-dimensional post processing, in which output pixel values are calculated by multi-directional, one-dimensional median filters on original volumetric datasets. The processed directions were selected except in in-plane (axial plane) direction, and consequently the in-plane spatial resolution was not affected by the filter. Also, in other directions, the spatial resolutions including slice thickness were almost maintained due to a characteristic of non-linear filtering of the median filter. From the results of phantom studies, the proposed algorithm could reduce standard deviation values as a noise index by up to 30% without affecting the spatial resolution of all directions, and therefore, contrast-to-noise ratio was improved by up to 30%. This newly developed filter algorithm will be useful for the diagnosis and radiation dose reduction of pediatric body CT images.

Entities:  

Mesh:

Year:  2009        PMID: 19536600      PMCID: PMC3046695          DOI: 10.1007/s10278-009-9218-4

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  18 in total

1.  Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative.

Authors:  David J Brenner
Journal:  Pediatr Radiol       Date:  2002-03-07

2.  Estimates of the cancer risks from pediatric CT radiation are not merely theoretical: comment on "point/counterpoint: in x-ray computed tomography, technique factors should be selected appropriate to patient size. against the proposition".

Authors:  D J Brenner; C D Elliston; E J Hall; W E Berdon
Journal:  Med Phys       Date:  2001-11       Impact factor: 4.071

3.  Detection of low-contrast objects: experimental comparison of single- and multi-detector row CT with a phantom.

Authors:  Francis R Verdun; Alban Denys; Jean-François Valley; Pierre Schnyder; Reto A Meuli
Journal:  Radiology       Date:  2002-05       Impact factor: 11.105

Review 4.  [Image evaluation in computed tomography].

Authors:  Katsuhiro Ichikawa
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2002-01

5.  Three-dimensional CT angiography of the hepatic artery: use of multi-detector row helical CT and a contrast agent.

Authors:  Masato Tanikake; Tadafumi Shimizu; Isamu Narabayashi; Mitsuru Matsuki; Kiyohiro Masuda; Kazuhiro Yamamoto; Yasuo Uesugi; Shushi Yoshikawa
Journal:  Radiology       Date:  2003-06       Impact factor: 11.105

Review 6.  Multi-detector row CT systems and image-reconstruction techniques.

Authors:  Thomas G Flohr; Stefan Schaller; Karl Stierstorfer; Herbert Bruder; Bernd M Ohnesorge; U Joseph Schoepf
Journal:  Radiology       Date:  2005-04-15       Impact factor: 11.105

7.  New method of evaluating edge-preserving adaptive filters for computed tomography (CT): digital phantom method.

Authors:  Miwa Okumura; Takamasa Ota; Shinsuke Tsukagoshi; Kazuhiro Katada
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2006-07-20

8.  Improvement in image quality of noncontrast head images in multidetector-row CT by volume helical scanning with a three-dimensional denoising filter.

Authors:  Tadashi Sasaki; Makoto Sasaki; Takao Hanari; Hiroshi Gakumazawa; Yasuhiro Noshi; Miwa Okumura
Journal:  Radiat Med       Date:  2007-08-27

9.  The noise power spectrum in computed X-ray tomography.

Authors:  S J Riederer; N J Pelc; D A Chesler
Journal:  Phys Med Biol       Date:  1978-05       Impact factor: 3.609

10.  Three-dimensional imaging of liver tumors using helical CT during intravenous injection of contrast medium.

Authors:  M Uchida; M Ishibashi; T Abe; H Nishimura; N Hayabuchi
Journal:  J Comput Assist Tomogr       Date:  1999 May-Jun       Impact factor: 1.826

View more
  1 in total

1.  Observer performance for adaptive, image-based denoising and filtered back projection compared to scanner-based iterative reconstruction for lower dose CT enterography.

Authors:  Joel G Fletcher; Amy K Hara; Jeff L Fidler; Alvin C Silva; John M Barlow; Rickey E Carter; Adam Bartley; Maria Shiung; David R Holmes; Nicolas K Weber; David H Bruining; Lifeng Yu; Cynthia H McCollough
Journal:  Abdom Imaging       Date:  2015-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.